W DOC AIRBUS | AMM A320F

Removal of the Check Valve


TASK 28-16-42-000-002-A
Removal of the Check Valve


WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
FIN: 222QM ** ON A/C NOT FOR ALL
FIN: 223QM ** ON A/C NOT FOR ALL
FIN: 224QM ** ON A/C NOT FOR ALL
FIN: 225QM ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
No specific
AR
PLUG - BLANKING
No specific
AR
SAFETY BARRIER(S)
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
98D57004014000
1
HOOK-COVER (RIB2-SURGE DOORS)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [222QM] (CHECK VALVE)
FOR [224QM] (CHECK VALVE)
540AB, 540BZ
FOR [223QM] (CHECK VALVE)
FOR [225QM] (CHECK VALVE)
640AB, 640BZ
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 28-10-00-910-001-A
Safety Procedures When You Do Work in a Fuel Tank
TASK 28-10-00-910-002-A
Access to the Fuel Tanks and the Work Areas
TASK 28-25-00-650-001-A
Pressure Defuel
TASK 28-25-00-650-003-A
To Drain Remaining Fuel from the Wing Tanks and the Center Tank
TASK 28-25-00-650-003-A-01
To Drain Remaining Fuel from the Wing Tanks and the Center Tank
TASK 57-27-11-000-001-A
Removal of the Access Panel
FOR [222QM] (CHECK VALVE)
FOR [224QM] (CHECK VALVE)
TASK 28-10-00-910-002-A
Access to the Fuel Tanks and the Work Areas
TASK 57-27-11-000-001-A
Removal of the Access Panel
TASK 57-27-12-000-002-A
Removal of the Rib 2 Access Panel 540AZ(640AZ) or 540BZ(640BZ)
FOR [223QM] (CHECK VALVE)
FOR [225QM] (CHECK VALVE)
TASK 28-10-00-910-002-A
Access to the Fuel Tanks and the Work Areas
TASK 57-27-11-000-001-A
Removal of the Access Panel
TASK 57-27-12-000-002-A
Removal of the Rib 2 Access Panel 540AZ(640AZ) or 540BZ(640BZ)
3. Job Set-up
Subtask 28-16-42-941-055-A ** ON A/C NOT FOR ALL
A. Safety Precautions
WARNING: BEFORE YOU DO WORK IN OR NEAR A FUEL TANK, MAKE SURE THAT YOU OBEY ALL THE SAFETY PROCEDURES. THIS WILL PREVENT INJURY TO PERSONS AND/OR DAMAGE TO THE AIRCRAFT.
   (1) You must obey the fuel safety procedures when you do work in a fuel tank (Ref. AMM TASK 28-10-00-910-001).
   (2) Put the SAFETY BARRIER(S) in position.
Subtask 28-16-42-860-052-A ** ON A/C NOT FOR ALL
B. Fuel Configuration
   (1) Defuel the applicable fuel tank (Ref. AMM TASK 28-25-00-650-001).
   (2) Drain the remaining fuel from the applicable fuel tank (Ref. AMM TASK 28-25-00-650-003).
Subtask 28-16-42-865-053-A ** ON A/C NOT FOR ALL
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUFUEL/L WING TK/PUMP2 SPLY7QAN26
121VUFUEL/L WING TK/PUMP1 SPLY1QAN23
121VUFUEL/R WING TK/PUMP2 SPLY8QAQ26
121VUFUEL/R WING TK/PUMP1 SPLY2QAQ23
123VUL WING TK/PUMP 1/STBY SPLY11QAAD12
123VUR WING TK/PUMP 1/STBY SPLY12QAAE12
Subtask 28-16-42-010-051-A ** ON A/C NOT FOR ALL
D. Get Access
   (1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE below the applicable zone 540(640).
   (2) Remove the applicable wing access panel (Ref. AMM TASK 57-27-11-000-001) and (Ref. AMM TASK 28-10-00-910-002):
     (a) FOR [222QM] (CHECK VALVE), [224QM] (CHECK VALVE)
remove 540AB
     (b) FOR [223QM] (CHECK VALVE), [225QM] (CHECK VALVE)
remove 640AB
   (3) Open the applicable rib 2 surge door and install the 98D57004014000 HOOK-COVER (RIB2-SURGE DOORS):
     (a) FOR [222QM] (CHECK VALVE), [224QM] (CHECK VALVE)
open 540BZ
     (b) FOR [223QM] (CHECK VALVE), [225QM] (CHECK VALVE)
open 640BZ
Subtask 28-16-42-010-051-C ** ON A/C NOT FOR ALL
D. Get Access
   (1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position below the applicable zone 540 (640).
   (2) Remove the applicable access panels that follow:
     (a) FOR [222QM] (CHECK VALVE), [224QM] (CHECK VALVE)
Remove 540AB (Ref. AMM TASK 28-10-00-910-002) and (Ref. AMM TASK 57-27-11-000-001).
     (b) FOR [223QM] (CHECK VALVE), [225QM] (CHECK VALVE)
Remove 640AB (Ref. AMM TASK 28-10-00-910-002) and (Ref. AMM TASK 57-27-11-000-001).
   (3) Remove the applicable RIB2 access panels that follow:
     (a) FOR [222QM] (CHECK VALVE), [224QM] (CHECK VALVE)
Remove 540BZ (Ref. AMM TASK 57-27-12-000-002).
     (b) FOR [223QM] (CHECK VALVE), [225QM] (CHECK VALVE)
Remove 640BZ (Ref. AMM TASK 57-27-12-000-002).
4. Procedure
Subtask 28-16-42-020-051-A ** ON A/C NOT FOR ALL
A. Removal of the Check Valve 222QM(223QM), 224QM(225QM)
   (1) Disconnect the pipe (3) at the check-valve (2).
   (2) Remove the check-valve (2).
   (3) Put the PLUG-BLANKING in each disconnected line end.
   (4) Remove and discard the O-ring (1).
[Rev.10 from 2021] 2026.04.02 06:17:17 UTC