Installation of the Actuator
TASK 28-15-51-400-001-A
Installation of the Actuator
Self Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Expendable Parts
E. Referenced Information
3. Job Set-up
Subtask 28-15-51-941-056-A ** ON A/C NOT FOR ALL
Subtask 28-15-51-410-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 07:02:14 UTC
Installation of the Actuator
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
WARNING:
MAKE SURE THAT THE FLIGHT CONTROL SAFETY-LOCKS AND THE WARNING NOTICES ARE IN POSITION.
WARNING:
MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
CAUTION:
BE CAREFUL WHEN YOU DO MAINTENANCE TASKS ON THE WING TRAILING EDGE:
1. Reason for the Job- DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE RACEWAYS.
- DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE INSTALLATIONS.
- MAKE SURE THAT THE ELECTRICAL CABLES ARE INSTALLED CORRECTLY. INCORRECT INSTALLATION CAN CAUSE DAMAGE.
Self Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 3M (10 FT) |
| No specific | AR | SAFETY BARRIER(S) |
| No specific | AR | WARNING NOTICE(S) |
| No specific | Torque wrench: range to between 0.113 and 0.102 m.daN (10.00 and 9.03 lbf.in ) ![]() | |
| 98D27803500001 | 1 | LOCKING TOOL ZERO POS |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.03GEE1) | Synthetic Oil base Grease-Fuel and Oxidized Environment Fluorinated - |
| (Material No.08BAA9) | Non Aqueous Cleaner-General - - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [10QP] (ACTUATOR-TRANSFER VALVE, R FWD SPAR) | |
| 622KB | |
| FOR [9QP] (ACTUATOR-TRANSFER VALVE, L FWD SPAR) | |
| 522KB | |
| FIG.ITEM | DESIGNATION | IPC-CSN |
|---|---|---|
| 6 | O-RING | AIPC 28-15-42-01-010 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 28-15-00-740-002-A | Functional (BITE) Test of the Intercell Transfer Valves |
Subtask 28-15-51-941-056-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) Make sure that the 98D27803500001 LOCKING TOOL ZERO POS is installed on the slat/flap control lever.
(2) Make sure that the WARNING NOTICE(S) is in position to tell persons not to operate the slat system.
(3) Make sure that the SAFETY BARRIER(S) are in position.
Subtask 28-15-51-865-052-A ** ON A/C NOT FOR ALL (1) Make sure that the 98D27803500001 LOCKING TOOL ZERO POS is installed on the slat/flap control lever.
(2) Make sure that the WARNING NOTICE(S) is in position to tell persons not to operate the slat system.
(3) Make sure that the SAFETY BARRIER(S) are in position.
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
Subtask 28-15-51-860-052-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | FUEL/XFR VALVE1/WING/R | 2QP | A11 |
| 49VU | FUEL/XFR VALVE1/WING/L | 1QP | A10 |
| 121VU | FUEL/XFR VALVE2/WING/R | 4QP | M23 |
| 121VU | FUEL/XFR VALVE2/WING/L | 3QP | M22 |
C. Aircraft Maintenance Configuration
(1) Make sure that the ACCESS PLATFORM 3M (10 FT) is below the applicable zone 520(620).
(2) Make sure that the applicable access panel is removed 522KB(622KB).
4. Procedure(1) Make sure that the ACCESS PLATFORM 3M (10 FT) is below the applicable zone 520(620).
(2) Make sure that the applicable access panel is removed 522KB(622KB).
CAUTION:
BE CAREFUL WHEN YOU DO MAINTENANCE TASKS ON THE WING TRAILING EDGE:
Subtask 28-15-51-420-053-A ** ON A/C NOT FOR ALL - DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE RACEWAYS.
- DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE INSTALLATIONS.
- MAKE SURE THAT THE ELECTRICAL CABLES ARE INSTALLED CORRECTLY. INCORRECT INSTALLATION CAN CAUSE DAMAGE.
A. Preparation for Installation
(1) Clean the component interfaces and the adjacent area with a Textile-Lint free Cotton - (Material No.14SBA1) made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) .
(2) Make sure that the parts retained from the removed component are clean and in the correct condition.
(3) Do an inspection of the component interfaces and the adjacent area.
(4) Apply Synthetic Oil base Grease-Fuel and Oxidized Environment Fluorinated - (Material No.03GEE1) to the new AIPC 28-15-42-01-010 O-RING (6).
Subtask 28-15-51-420-050-A ** ON A/C NOT FOR ALL (1) Clean the component interfaces and the adjacent area with a Textile-Lint free Cotton - (Material No.14SBA1) made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) .
(2) Make sure that the parts retained from the removed component are clean and in the correct condition.
(3) Do an inspection of the component interfaces and the adjacent area.
(4) Apply Synthetic Oil base Grease-Fuel and Oxidized Environment Fluorinated - (Material No.03GEE1) to the new AIPC 28-15-42-01-010 O-RING (6).
B. Installation of the Actuator 9QP(10QP)
(2) Align the transfer-valve drive slot with the transfer valve actuator (5).
(3) Install the new O-ring (6) on the transfer valve drive (1).
(4) Carefully engage the transfer valve actuator (5) on the transfer-valve drive (1).
(a) Make sure that the mating surfaces of the actuator (5) and the transfer valve drive (1) engage correctly.
(b) Make sure that there is zero clearance (around all of the circumference) between the flange of the:
.
(7) Make sure that the clamp (3) is fully engaged.
Subtask 28-15-51-865-053-A ** ON A/C NOT FOR ALL CAUTION:
MAKE SURE THAT YOU CORRECTLY ALIGN THE POSITIONS OF THE ROLL PIN ON THE DRIVE SPINDLE AND THE PIN HOLE IN THE ACTUATOR. IF NOT, THE ACTUATOR WILL NOT OPERATE THE VALVE CORRECTLY AND CAN CAUSE FUEL LEAKAGE.
(1) Make sure the transfer-valve drive slot moves freely. (2) Align the transfer-valve drive slot with the transfer valve actuator (5).
(3) Install the new O-ring (6) on the transfer valve drive (1).
(4) Carefully engage the transfer valve actuator (5) on the transfer-valve drive (1).
(a) Make sure that the mating surfaces of the actuator (5) and the transfer valve drive (1) engage correctly.
(b) Make sure that there is zero clearance (around all of the circumference) between the flange of the:
- actuator (5)
- transfer valve drive (1).
NOTE: There will always be no clearance when the pins and the grooves are all correctly aligned.
(5) Put the clamp (3) and install the bolt (2). CAUTION:
DO NOT TORQUE THE V-CLAMP(S) TO MORE THAN THE SPECIFIED VALUE. THIS PREVENTS DAMAGE TO THE FLANGE SURFACES.
(6) TORQUE the bolt (2) to between 0.113 and 0.102 m.daN (10.00 and 9.03 lbf.in )
. (7) Make sure that the clamp (3) is fully engaged.
NOTE: The clamp (3) is fully engaged if no part of the flange shows for the:
(8) Remove the blanking caps and install the electrical connector (4). - actuator (5)
- transfer valve drive (1).
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 28-15-51-710-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | FUEL/XFR VALVE1/WING/R | 2QP | A11 |
| 49VU | FUEL/XFR VALVE1/WING/L | 1QP | A10 |
| 121VU | FUEL/XFR VALVE2/WING/R | 4QP | M23 |
| 121VU | FUEL/XFR VALVE2/WING/L | 3QP | M22 |
D. Operational Test
(1) Do a BITE of the intercell transfer valves (Ref. AMM TASK 28-15-00-740-002).
5. Close-up(1) Do a BITE of the intercell transfer valves (Ref. AMM TASK 28-15-00-740-002).
Subtask 28-15-51-410-050-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the access panel:
(a) FOR [9QP] (ACTUATOR-TRANSFER VALVE, L FWD SPAR)
install 522KB.
(b) FOR [10QP] (ACTUATOR-TRANSFER VALVE, R FWD SPAR)
install 622KB.
Subtask 28-15-51-942-051-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the access panel:
(a) FOR [9QP] (ACTUATOR-TRANSFER VALVE, L FWD SPAR)
install 522KB.
(b) FOR [10QP] (ACTUATOR-TRANSFER VALVE, R FWD SPAR)
install 622KB.
B. Removal of Equipment
(1) Remove the 98D27803500001 LOCKING TOOL ZERO POS from the slat/flap control lever.
(2) Remove the safety barriers.
(3) Remove the WARNING NOTICE(S).
(4) Remove the access platform(s).
(5) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(1) Remove the 98D27803500001 LOCKING TOOL ZERO POS from the slat/flap control lever.
(2) Remove the safety barriers.
(3) Remove the WARNING NOTICE(S).
(4) Remove the access platform(s).
(5) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
Transfer Valve Actuators