W DOC AIRBUS | AMM A320F

Installation of the Actuator


TASK 28-15-51-400-001-A
Installation of the Actuator


WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
WARNING: MAKE SURE THAT THE FLIGHT CONTROL SAFETY-LOCKS AND THE WARNING NOTICES ARE IN POSITION.
WARNING: MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
CAUTION: BE CAREFUL WHEN YOU DO MAINTENANCE TASKS ON THE WING TRAILING EDGE:
  • DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE RACEWAYS.
  • DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE INSTALLATIONS.
  • MAKE SURE THAT THE ELECTRICAL CABLES ARE INSTALLED CORRECTLY. INCORRECT INSTALLATION CAN CAUSE DAMAGE.
FIN: 10QP ** ON A/C NOT FOR ALL
FIN: 9QP ** ON A/C NOT FOR ALL
1. Reason for the Job
Self Explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 3M (10 FT)
No specific
AR
SAFETY BARRIER(S)
No specific
AR
WARNING NOTICE(S)
No specific
Torque wrench: range to between 0.113 and 0.102 m.daN (10.00 and 9.03 lbf.in ) T
98D27803500001
1
LOCKING TOOL ZERO POS
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.03GEE1)
Synthetic Oil base Grease-Fuel and Oxidized Environment Fluorinated -
(Material No.08BAA9)
Non Aqueous Cleaner-General - -
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [10QP] (ACTUATOR-TRANSFER VALVE, R FWD SPAR)
622KB
FOR [9QP] (ACTUATOR-TRANSFER VALVE, L FWD SPAR)
522KB
 D. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
6
O-RING
AIPC 28-15-42-01-010
 E. Referenced Information
REFERENCE
DESIGNATION
TASK 28-15-00-740-002-A
Functional (BITE) Test of the Intercell Transfer Valves
3. Job Set-up
Subtask 28-15-51-941-056-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) Make sure that the 98D27803500001 LOCKING TOOL ZERO POS is installed on the slat/flap control lever.
   (2) Make sure that the WARNING NOTICE(S) is in position to tell persons not to operate the slat system.
   (3) Make sure that the SAFETY BARRIER(S) are in position.
Subtask 28-15-51-865-052-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUFUEL/XFR VALVE1/WING/R2QPA11
49VUFUEL/XFR VALVE1/WING/L1QPA10
121VUFUEL/XFR VALVE2/WING/R4QPM23
121VUFUEL/XFR VALVE2/WING/L3QPM22
Subtask 28-15-51-860-052-A ** ON A/C NOT FOR ALL
C. Aircraft Maintenance Configuration
   (1) Make sure that the ACCESS PLATFORM 3M (10 FT) is below the applicable zone 520(620).
   (2) Make sure that the applicable access panel is removed 522KB(622KB).
4. Procedure
CAUTION: BE CAREFUL WHEN YOU DO MAINTENANCE TASKS ON THE WING TRAILING EDGE:
  • DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE RACEWAYS.
  • DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE INSTALLATIONS.
  • MAKE SURE THAT THE ELECTRICAL CABLES ARE INSTALLED CORRECTLY. INCORRECT INSTALLATION CAN CAUSE DAMAGE.
Subtask 28-15-51-420-053-A ** ON A/C NOT FOR ALL
A. Preparation for Installation
   (1) Clean the component interfaces and the adjacent area with a Textile-Lint free Cotton - (Material No.14SBA1) made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) .
   (2) Make sure that the parts retained from the removed component are clean and in the correct condition.
   (3) Do an inspection of the component interfaces and the adjacent area.
   (4) Apply Synthetic Oil base Grease-Fuel and Oxidized Environment Fluorinated - (Material No.03GEE1) to the new AIPC 28-15-42-01-010 O-RING (6).
Subtask 28-15-51-420-050-A ** ON A/C NOT FOR ALL Subtask 28-15-51-865-053-A ** ON A/C NOT FOR ALL
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUFUEL/XFR VALVE1/WING/R2QPA11
49VUFUEL/XFR VALVE1/WING/L1QPA10
121VUFUEL/XFR VALVE2/WING/R4QPM23
121VUFUEL/XFR VALVE2/WING/L3QPM22
Subtask 28-15-51-710-050-A ** ON A/C NOT FOR ALL
5. Close-up
Subtask 28-15-51-410-050-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Install the access panel:

     (a) FOR [9QP] (ACTUATOR-TRANSFER VALVE, L FWD SPAR)
install 522KB.

     (b) FOR [10QP] (ACTUATOR-TRANSFER VALVE, R FWD SPAR)
install 622KB.
Subtask 28-15-51-942-051-A ** ON A/C NOT FOR ALL
B. Removal of Equipment
   (1) Remove the 98D27803500001 LOCKING TOOL ZERO POS from the slat/flap control lever.
   (2) Remove the safety barriers.
   (3) Remove the WARNING NOTICE(S).
   (4) Remove the access platform(s).
   (5) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
[Rev.10 from 2021] 2026.04.02 07:02:14 UTC