W DOC AIRBUS | AMM A320F

Removal of the Actuator


TASK 28-15-51-000-002-A
Removal of the Actuator


WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
WARNING: MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
CAUTION: BE CAREFUL WHEN YOU DO MAINTENANCE TASKS ON THE WING TRAILING EDGE:
  • DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE RACEWAYS.
  • DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE INSTALLATIONS.
  • MAKE SURE THAT THE ELECTRICAL CABLES ARE INSTALLED CORRECTLY. INCORRECT INSTALLATION CAN CAUSE DAMAGE.
FIN: 11QP ** ON A/C NOT FOR ALL
FIN: 12QP ** ON A/C NOT FOR ALL
1. Reason for the Job
Self Explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 3M (10 FT)
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY BARRIER(S)
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 27-50-00-866-008-A
Extension of the Flaps on the Ground
TASK 27-50-00-866-008-A-01
Extension of the Flaps/Slats on the Ground
TASK 27-60-00-866-002-A
Extension-Retraction of the Spoilers for Maintenance
3. Job Set-up
Subtask 28-15-51-941-051-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) Put the SAFETY BARRIER(S) in position.
   (2) Put a WARNING NOTICE(S) in position to tell persons not to operate the flight controls.
Subtask 28-15-51-010-055-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Extend the flaps fully (Ref. AMM TASK 27-50-00-866-008).
   (2) Make sure that the 98D27803000000 LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION is on the slat/flap control lever.
   (3) Extend the Spoiler No. 3 (Ref. AMM TASK 27-60-00-866-002).
   (4) Make sure that the 98D27604000000 COLLAR-SAFETY, SPOILER or 98D27604004000 COLLAR SAFETY SPOILER is on the applicable spoiler servo-control.
   (5) Put the ACCESS PLATFORM 3M (10 FT) below the applicable zone 575(675).
Subtask 28-15-51-865-051-A ** ON A/C NOT FOR ALL
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUFUEL/XFR VALVE1/WING/R2QPA11
49VUFUEL/XFR VALVE1/WING/L1QPA10
121VUFUEL/XFR VALVE2/WING/R4QPM23
121VUFUEL/XFR VALVE2/WING/L3QPM22
4. Procedure
CAUTION: BE CAREFUL WHEN YOU DO MAINTENANCE TASKS ON THE WING TRAILING EDGE:
  • DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE RACEWAYS.
  • DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE INSTALLATIONS.
  • MAKE SURE THAT THE ELECTRICAL CABLES ARE INSTALLED CORRECTLY. INCORRECT INSTALLATION CAN CAUSE DAMAGE.
Subtask 28-15-51-020-051-A ** ON A/C NOT FOR ALL
A. Removal of the Actuator 11QP(12QP)
   (1) Disconnect the electrical connector (4).
   (2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (3) Remove the bolt (2), the clamp (3) and remove the actuator (5) from the transfer valve drive (1).
   (4) Remove and discard the O-ring (6).
[Rev.10 from 2021] 2026.04.02 07:02:15 UTC