Inspection of the Drain Mast Outlet for Obstruction
TASK 28-13-00-200-001-A
Inspection of the Drain Mast Outlet for Obstruction
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 28-13-00-941-056-A
Subtask 28-13-00-210-051-A
Subtask 28-13-00-942-051-A
[Rev.10 from 2021]
2026.04.02 06:42:58 UTC
Inspection of the Drain Mast Outlet for Obstruction
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
ZONE: 148
1. Reason for the Job2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | SAFETY BARRIER(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 148 | MAIN GEAR WELL AND HYDRAULIC COMPARTMENT |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 28-18-00-200-001-A | Detailed Inspection of Vapour Seal (SFAR88) |
| TASK 28-13-43-000-001-A | Removal of the Drain Mast (for corrective action) |
| TASK 28-13-43-400-001-A | Installation of the Drain Mast (for corrective action) |
Subtask 28-13-00-941-056-A
A. Safety Precautions
(1) Put the SAFETY BARRIER(S) in position.
4. Procedure(1) Put the SAFETY BARRIER(S) in position.
Subtask 28-13-00-210-051-A
A. Inspection of the Drain Mast for Obstruction
(1) Make sure that the drain mast openings are not blocked. Remove any blockages from the drain mast openings.
(2) Examine the drain mast for damage, cracks, corrosion and correct attachment.
(3) If the drain mast is blocked or damaged, do an inspection of the vapour seal (Ref. AMM TASK 28-18-00-200-001).
5. Close-up(1) Make sure that the drain mast openings are not blocked. Remove any blockages from the drain mast openings.
(2) Examine the drain mast for damage, cracks, corrosion and correct attachment.
(3) If the drain mast is blocked or damaged, do an inspection of the vapour seal (Ref. AMM TASK 28-18-00-200-001).
NOTE: If the drain mast becomes blocked, the center tank vent system can become pressurized. This can cause damage to the vapour seal.
(4) If necessary, replace the drain mast (Ref. AMM TASK 28-13-43-000-001) and (Ref. AMM TASK 28-13-43-400-001). Subtask 28-13-00-942-051-A
A. Removal of Equipment
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the safety barriers.
(3) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the safety barriers.
(3) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
Drain Mast Inspection