Installation of the Check Valve
TASK 28-12-44-400-001-A
Installation of the Check Valve
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 28-12-44-941-065-B
Subtask 28-12-44-420-050-A
Subtask 28-12-44-410-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 07:02:02 UTC
Installation of the Check Valve
WARNING:
OBEY THE FUEL SAFETY PROCEDURES.
WARNING:
BEFORE YOU DO WORK IN OR NEAR A FUEL TANK, MAKE SURE THAT YOU OBEY ALL THE SAFETY PROCEDURES. THIS WILL PREVENT INJURY TO PERSONS AND/OR DAMAGE TO THE AIRCRAFT.
WARNING:
BE CAREFUL NOT TO GET AIRCRAFT FUEL IN YOUR MOUTH OR IN YOUR EYES.
IF YOU GET FUEL ON YOUR SKIN OR ON YOUR CLOTHES, FLUSH IT IMMEDIATELY WITH WATER.
IF NECESSARY, GET MEDICAL HELP.
AIRCRAFT FUEL IS POISONOUS.
WARNING:
DO NOT GET YOUR CLOTHES SOAKED WITH FUEL.
WARNING:
MAKE SURE THAT YOU HAVE THE CORRECT FIRE FIGHTING EQUIPMENT AVAILABLE.
WARNING:
MAKE SURE THAT THE FLIGHT CONTROL SAFETY-LOCKS AND THE WARNING NOTICES ARE IN POSITION.
WARNING:
MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| No specific | AR | SAFETY BARRIER(S) |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 140 | CENTER WING |
| 147AZ |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 12-11-28-650-003-A | Pressure Refuel with Automatic Control |
| TASK 28-00-00-910-001-A | Fuel Safety Procedures |
| TASK 28-10-00-910-001-A | Safety Procedures When You Do Work in a Fuel Tank |
| TASK 28-10-00-910-002-A | Access to the Fuel Tanks and the Work Areas |
| TASK 28-25-00-650-001-A | Pressure Defuel |
| TASK 28-25-00-650-003-A | To Drain Remaining Fuel from the Wing Tanks and the Center Tank |
| TASK 28-25-00-650-003-A-01 | To Drain Remaining Fuel from the Wing Tanks and the Center Tank |
| TASK 28-25-00-869-001-A | Fuel Transfer |
| TASK 32-12-00-010-001-A | Open the Main Gear Doors for Access |
| TASK 32-12-00-410-001-A | Close the Main Gear Doors after Access |
| TASK 57-17-11-000-001-A | Removal of Access Cover 147AZ(148AZ) |
| TASK 57-17-11-000-001-B | Removal of Access Cover 148AZ or/and the ACT-Equipment Support Door |
| TASK 57-17-11-400-001-A | Installation of Access Cover 147AZ(148AZ) |
| TASK 57-17-11-400-001-B | Installation of Access Cover 148AZ or/and the ACT-Equipment Support-Door |
Subtask 28-12-44-941-065-B
A. Safety Precautions
(1) Obey the fuel safety procedures (Ref. AMM TASK 28-00-00-910-001).
(2) Obey the fuel safety procedures when you do work in a fuel tank (Ref. AMM TASK 28-10-00-910-001).
(3) Make sure that the SAFETY BARRIER(S) is (are) in position, if necessary.
(4) Make sure that the WARNING NOTICE(S) is (are) in position to tell persons not to operate the Main Landing Gear (MLG) doors.
Subtask 28-12-44-860-052-A ** ON A/C NOT FOR ALL (1) Obey the fuel safety procedures (Ref. AMM TASK 28-00-00-910-001).
(2) Obey the fuel safety procedures when you do work in a fuel tank (Ref. AMM TASK 28-10-00-910-001).
(3) Make sure that the SAFETY BARRIER(S) is (are) in position, if necessary.
(4) Make sure that the WARNING NOTICE(S) is (are) in position to tell persons not to operate the Main Landing Gear (MLG) doors.
B. Aircraft Maintenance Configuration
(1) Make sure that the center tank is defueled (Ref. AMM TASK 28-25-00-650-001).
(2) Make sure that the remaining fuel is drained from the center tank (Ref. AMM TASK 28-25-00-650-003).
(3) Make sure that the LH MLG door is open (Ref. AMM TASK 32-12-00-010-001).
(4) Make sure that the 460005835 SLEEVE - GROUND LOCK is installed on the LH MLG door actuator.
(5) Make sure that the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE is below access panel 147AZ or the ACT-Equipment Support Door.
(6) Make sure that access panel 147AZ or the ACT-Equipment Support Door is removed (Ref. AMM TASK 28-10-00-910-002), (Ref. AMM TASK 57-17-11-000-001).
Subtask 28-12-44-860-052-C ** ON A/C NOT FOR ALL (1) Make sure that the center tank is defueled (Ref. AMM TASK 28-25-00-650-001).
(2) Make sure that the remaining fuel is drained from the center tank (Ref. AMM TASK 28-25-00-650-003).
(3) Make sure that the LH MLG door is open (Ref. AMM TASK 32-12-00-010-001).
(4) Make sure that the 460005835 SLEEVE - GROUND LOCK is installed on the LH MLG door actuator.
(5) Make sure that the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE is below access panel 147AZ or the ACT-Equipment Support Door.
(6) Make sure that access panel 147AZ or the ACT-Equipment Support Door is removed (Ref. AMM TASK 28-10-00-910-002), (Ref. AMM TASK 57-17-11-000-001).
B. Aircraft Maintenance Configuration
(1) Make sure that the center tank is defueled (Ref. AMM TASK 28-25-00-650-001).
(2) Make sure that the remaining fuel is drained from the center tank (Ref. AMM TASK 28-25-00-650-003).
(3) Make sure that the LH MLG door is open (Ref. AMM TASK 32-12-00-010-001).
(4) Make sure that the 460005835 SLEEVE - GROUND LOCK is installed on the LH MLG door actuator.
(5) Make sure that the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE is below the ACT-Equipment Support Door.
(6) Make sure that the ACT-Equipment Support Door is removed (Ref. AMM TASK 28-10-00-910-002), (Ref. AMM TASK 57-17-11-000-001).
Subtask 28-12-44-865-058-A (1) Make sure that the center tank is defueled (Ref. AMM TASK 28-25-00-650-001).
(2) Make sure that the remaining fuel is drained from the center tank (Ref. AMM TASK 28-25-00-650-003).
(3) Make sure that the LH MLG door is open (Ref. AMM TASK 32-12-00-010-001).
(4) Make sure that the 460005835 SLEEVE - GROUND LOCK is installed on the LH MLG door actuator.
(5) Make sure that the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE is below the ACT-Equipment Support Door.
(6) Make sure that the ACT-Equipment Support Door is removed (Ref. AMM TASK 28-10-00-910-002), (Ref. AMM TASK 57-17-11-000-001).
C. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | FUEL/HI/LVL/SPLY | 1QJ | L25 |
| 121VU | FUEL/RFL/DFL/SPLY | 2QU | L24 |
| 121VU | FUEL/RFL/DFL/XFR/DEFUEL/VALVE | 1QU | L23 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | ACT PUMP SUPPLY | 25QH | Q29 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | FUEL/ACT AIR SOV/MAN/SPLY | 64QH | J20 |
| 121VU | FUEL/ACT AIR SOV/AUTO/SPLY | 63QH | J19 |
| 121VU | FUEL/ACT XFR VLV/MOT2 | 66QH | J18 |
| 121VU | FUEL/ACT XFR VLV/MOT1 | 65QH | J17 |
| 121VU | FUEL/HI/LVL/SPLY | 1QJ | L24 |
| 121VU | FUEL/RFL/DFL/SPLY | 2QU | L23 |
| 121VU | FUEL/RFL/DFL/XFR/DEFUEL/VALVE | 1QU | L22 |
| 121VU | FUEL/ACT VENT VLV/MAN/SPLY | 62QH | L21 |
| 121VU | FUEL/ACT VENT VLV/AUTO/SPLY | 61QH | L20 |
| 121VU | FUEL/ACT/FUEL PUMP/SPLY | 25QH | Q29 |
Subtask 28-12-44-420-050-A
A. Installation of the Check Valve
Check Valve 50QM(51QM) 52QM(53QM) 120QM(121QM) 93QM ** ON A/C NOT FOR ALL
Check Valve 50QM(51QM) 120QM(121QM) 93QM ** ON A/C NOT FOR ALL
(1) Clean the component interfaces and the adjacent area.
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Make sure that the parts retained from the removed component are clean and in the correct condition.
(4) Hold the clamp (2) on the end of the pipe (1) and install the check-valve (3), with the flat face horizontal.
(5) Move the clamp (2) on to the check-valve (3) and tighten the clamp (2).
Subtask 28-12-44-865-059-A
Check Valve 50QM(51QM) 52QM(53QM) 120QM(121QM) 93QM ** ON A/C NOT FOR ALL
Check Valve 50QM(51QM) 120QM(121QM) 93QM ** ON A/C NOT FOR ALL (2) Do an inspection of the component interfaces and the adjacent area.
(3) Make sure that the parts retained from the removed component are clean and in the correct condition.
(4) Hold the clamp (2) on the end of the pipe (1) and install the check-valve (3), with the flat face horizontal.
(5) Move the clamp (2) on to the check-valve (3) and tighten the clamp (2).
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
5. Close-up| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | FUEL/HI/LVL/SPLY | 1QJ | L25 |
| 121VU | FUEL/RFL/DFL/SPLY | 2QU | L24 |
| 121VU | FUEL/RFL/DFL/XFR/DEFUEL/VALVE | 1QU | L23 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | ACT PUMP SUPPLY | 25QH | Q29 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | FUEL/ACT AIR SOV/MAN/SPLY | 64QH | J20 |
| 121VU | FUEL/ACT AIR SOV/AUTO/SPLY | 63QH | J19 |
| 121VU | FUEL/ACT XFR VLV/MOT2 | 66QH | J18 |
| 121VU | FUEL/ACT XFR VLV/MOT1 | 65QH | J17 |
| 121VU | FUEL/HI/LVL/SPLY | 1QJ | L24 |
| 121VU | FUEL/RFL/DFL/SPLY | 2QU | L23 |
| 121VU | FUEL/RFL/DFL/XFR/DEFUEL/VALVE | 1QU | L22 |
| 121VU | FUEL/ACT VENT VLV/MAN/SPLY | 62QH | L21 |
| 121VU | FUEL/ACT VENT VLV/AUTO/SPLY | 61QH | L20 |
| 121VU | FUEL/ACT/FUEL PUMP/SPLY | 25QH | Q29 |
Subtask 28-12-44-410-050-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install access panel 147AZ or the ACT-Equipment Support Door (Ref. AMM TASK 57-17-11-400-001).
(3) Remove the access platform(s).
(4) Close the LH MLG door (Ref. AMM TASK 32-12-00-410-001).
Subtask 28-12-44-410-050-C ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install access panel 147AZ or the ACT-Equipment Support Door (Ref. AMM TASK 57-17-11-400-001).
(3) Remove the access platform(s).
(4) Close the LH MLG door (Ref. AMM TASK 32-12-00-410-001).
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the access platform(s).
(3) Close the LH MLG door (Ref. AMM TASK 32-12-00-410-001).
(4) Install the ACT-Equipment Support Door (Ref. AMM TASK 28-10-00-910-002), (Ref. AMM TASK 57-17-11-400-001).
Subtask 28-12-44-650-060-A (1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the access platform(s).
(3) Close the LH MLG door (Ref. AMM TASK 32-12-00-410-001).
(4) Install the ACT-Equipment Support Door (Ref. AMM TASK 28-10-00-910-002), (Ref. AMM TASK 57-17-11-400-001).
B. Fuel Configuration
(1) Refuel, defuel or transfer fuel as necessary (Ref. AMM TASK 12-11-28-650-003), (Ref. AMM TASK 28-25-00-650-001) or (Ref. AMM TASK 28-25-00-869-001).
Subtask 28-12-44-942-051-A (1) Refuel, defuel or transfer fuel as necessary (Ref. AMM TASK 12-11-28-650-003), (Ref. AMM TASK 28-25-00-650-001) or (Ref. AMM TASK 28-25-00-869-001).
C. Removal of Equipment
(1) If installed, remove the safety barriers.
(2) Remove the WARNING NOTICE(S).
(3) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(1) If installed, remove the safety barriers.
(2) Remove the WARNING NOTICE(S).
(3) Remove the ground support and maintenance equipment, the special and standard tools and all other items.