W DOC AIRBUS | AMM A320F

Removal of the ACT Fuel Drain-Valve(s)


TASK 28-12-44-000-006-A
Removal of the ACT Fuel Drain-Valve(s)


WARNING: OBEY THE FUEL SAFETY PROCEDURES.
WARNING: BEFORE YOU DO WORK IN OR NEAR A FUEL TANK, MAKE SURE THAT YOU OBEY ALL THE SAFETY PROCEDURES. THIS WILL PREVENT INJURY TO PERSONS AND/OR DAMAGE TO THE AIRCRAFT.
WARNING: BE CAREFUL NOT TO GET AIRCRAFT FUEL IN YOUR MOUTH OR IN YOUR EYES. IF YOU GET FUEL ON YOUR SKIN OR ON YOUR CLOTHES, FLUSH IT IMMEDIATELY WITH WATER. IF NECESSARY, GET MEDICAL HELP. AIRCRAFT FUEL IS POISONOUS.
WARNING: DO NOT GET YOUR CLOTHES SOAKED WITH FUEL.
WARNING: MAKE SURE THAT YOU HAVE THE CORRECT FIRE FIGHTING EQUIPMENT AVAILABLE.
ZONE: 130
ZONE: 150
ZONE: 160
FIN: 227QM1 ** ON A/C NOT FOR ALL
FIN: 227QM2 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT)
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY BARRIER(S)
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
130
FWD CARGO COMPT AFT BULKHEAD OF AVNCS COMPT TO FWD PRESSURE BULKHEAD OF WING CENTER BOX
150
AFT CARGO COMPARTMENT FWD PRESS BULKHEAD TO AFT BULKHEAD OF AFT CARGO COMPARTMENT
160
BULK CARGO COMPARTMENT AFT BULKHEAD OF AFT CARGO COMPARTMENT TO AFT BULKHEAD OF BULK CARGO COMPARTMENT
826
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 28-00-00-910-001-A
Fuel Safety Procedures
TASK 28-10-00-910-001-A
Safety Procedures When You Do Work in a Fuel Tank
TASK 28-25-00-650-001-A
Pressure Defuel
TASK 28-25-00-650-003-A
To Drain Remaining Fuel from the Wing Tanks and the Center Tank
TASK 28-25-00-650-003-A-01
To Drain Remaining Fuel from the Wing Tanks and the Center Tank
TASK 52-30-00-860-001-A
Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
FOR [227QM1] (VALVE-FUEL DRAIN, ACT1)
TASK 28-10-00-910-002-A
Access to the Fuel Tanks and the Work Areas
TASK 28-11-27-000-003-A
Removal of the Additional Center Tank No.2 (ACT AFT2)
TASK 28-11-37-000-001-A
Removal of the Inner Manhole-Cover ACT
TASK 28-11-37-000-004-A
Removal of the Outer Manhole-Cover ACT
FOR [227QM2] (VALVE-FUEL DRAIN, ACT2)
TASK 28-10-00-910-002-A
Access to the Fuel Tanks and the Work Areas
TASK 28-11-37-000-001-A
Removal of the Inner Manhole-Cover ACT
TASK 28-11-37-000-004-A
Removal of the Outer Manhole-Cover ACT
TASK 28-11-49-000-002-A
Removal of the Additional Center Tank (ACT) Integrated Impact Wall
3. Job Set-up
Subtask 28-12-44-941-071-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) Obey the fuel safety procedures (Ref. AMM TASK 28-00-00-910-001).
   (2) Obey the safety procedures when you do work in a fuel tank (Ref. AMM TASK 28-10-00-910-001).
   (3) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
Subtask 28-12-44-860-062-A ** ON A/C NOT FOR ALL
B. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 28-12-44-650-064-A ** ON A/C NOT FOR ALL
C. Fuel Configuration
   (1) Defuel the applicable fuel tank (Ref. AMM TASK 28-25-00-650-001).
   (2) Drain the remaining fuel from the applicable fuel tank (Ref. AMM TASK 28-25-00-650-003).
   (3) On refuel/defuel control panels 801VU and 800VU, on fuel control panel 40VU and on Additional Center Tank (ACT) control panel 28VU:
     (a) Put the WARNING NOTICE(S) in position to tell persons not to operate the fuel system.
Subtask 28-12-44-865-054-A ** ON A/C NOT FOR ALL
D. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUFUEL/ACT RFL/VLV/SPLY & CTL43QUJ21
121VUFUEL/ACT XFR VLV/MOT266QHJ18
121VUFUEL/ACT XFR VLV/MOT165QHJ17
121VUFUEL/RFL/DFL INLET VLV/AFT 1 & 253QUJ15
121VUFUEL/INLET VLV MOT2 AUTO SP AFT 244QH2K16
121VUFUEL/INLET VLV MOT2 AUTO SP AFT 144QH1K15
121VUFUEL/INLET VLV/MOT1/AFT 284QHL29
121VUFUEL/INLET VLV/MOT1/MAN SPLY/AFT 146QHL28
121VUFUEL/RFL/DFL CTL/AFT 1 & 249QUL26
121VUFUEL/ACT/FUEL PUMP/SPLY25QHQ29
Subtask 28-12-44-010-062-C ** ON A/C NOT FOR ALL
E. Get Access
   (1) Put an ACCESS PLATFORM 2M (6 FT) in position below aft cargo compartment door 826.
   (2) Open aft cargo-compartment door 826 (Ref. AMM TASK 52-30-00-860-001).
   (3) Set CARGO COMPT LIGHT switch 8LU to the ON position.
   (4) FOR [227QM1] (VALVE-FUEL DRAIN, ACT1)
     (a) Remove the Additional Center Tank (ACT) AFT2 (Ref. AMM TASK 28-11-27-000-003).
     (b) Remove the manhole cover from the rear wall of the ACT AFT1 (Ref. AMM TASK 28-11-37-000-004), (Ref. AMM TASK 28-11-37-000-001) and (Ref. AMM TASK 28-10-00-910-002).
   (5) FOR [227QM2] (VALVE-FUEL DRAIN, ACT2)
     (a) Remove the integrated impact wall from the ACT AFT2 (Ref. AMM TASK 28-11-49-000-002).
     (b) Remove the manhole-cover from the rear wall of the ACT AFT2 (Ref. AMM TASK 28-11-37-000-004), (Ref. AMM TASK 28-11-37-000-001) and (Ref. AMM TASK 28-10-00-910-002).
4. Procedure
Subtask 28-12-44-020-057-A ** ON A/C NOT FOR ALL
A. Removal of the ACT Fuel Drain-Valve
   (1) Loosen the screw of the clamp (2) and move it along the pipe (1) away from the drain valve (3).
   (2) Remove the drain valve (3) from the pipe (1) and remove the clamp (2).
   (3) Put the CAP - BLANKING on all the open end of the pipe(s).
[Rev.10 from 2021] 2026.04.02 06:17:11 UTC