W DOC AIRBUS | AMM A320F

Removal of the Check Valve


TASK 28-12-44-000-001-A
Removal of the Check Valve


WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
FIN: 52QM ** ON A/C NOT FOR ALL
FIN: 53QM ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE
No specific
AR
SAFETY BARRIER(S)
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 28-10-00-910-001-A
Safety Procedures When You Do Work in a Fuel Tank
TASK 28-10-00-910-002-A
Access to the Fuel Tanks and the Work Areas
TASK 28-25-00-650-001-A
Pressure Defuel
TASK 28-25-00-650-003-A
To Drain Remaining Fuel from the Wing Tanks and the Center Tank
TASK 28-25-00-650-003-A-01
To Drain Remaining Fuel from the Wing Tanks and the Center Tank
TASK 57-27-11-000-002-A
Removal of the Access Panel
3. Job Set-up
Subtask 28-12-44-941-061-A ** ON A/C NOT FOR ALL
A. Safety Precautions
WARNING: BEFORE YOU DO WORK IN OR NEAR A FUEL TANK, MAKE SURE THAT YOU OBEY ALL THE SAFETY PROCEDURES. THIS WILL PREVENT INJURY TO PERSONS AND/OR DAMAGE TO THE AIRCRAFT.
   (1) You must obey the fuel safety procedures (Ref. AMM TASK 28-10-00-910-001) when you do work in a fuel tank.
   (2) Put the SAFETY BARRIER(S) in position.
Subtask 28-12-44-860-053-A ** ON A/C NOT FOR ALL
B. Fuel Configuration
   (1) Defuel the applicable fuel tank (Ref. AMM TASK 28-25-00-650-001).
   (2) Drain the remaining fuel from the applicable fuel tank (Ref. AMM TASK 28-25-00-650-003).
Subtask 28-12-44-010-058-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE below the applicable access panel 540JB(640JB).
   (2) Remove the applicable access panel 540JB(640JB) (Ref. AMM TASK 28-10-00-910-002), (Ref. AMM TASK 57-27-11-000-002).
4. Procedure
Subtask 28-12-44-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Check Valve 52QM(53QM)
   (1) Loosen the clamp (2) and move it along the pipe (1) away from the check-valve (3).
   (2) Remove the check-valve (3) from the pipe (1) and remove the clamp (2).
[Rev.10 from 2021] 2026.04.02 06:17:11 UTC