W DOC AIRBUS | AMM A320F

Removal of the Overpressure Protector


TASK 28-12-41-000-002-A
Removal of the Overpressure Protector


WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
FIN: 102QM ** ON A/C NOT FOR ALL
FIN: 103QM ** ON A/C NOT FOR ALL
1. Reason for the Job
Self Explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 3M (10 FT)
No specific
AR
SAFETY BARRIER(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [102QM] (PROTECTOR-OVERPRESSURE, L WING TK)
540JB, 540KB
FOR [103QM] (PROTECTOR-OVERPRESSURE, R WING TK)
640JB, 640KB
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 28-10-00-910-001-A
Safety Procedures When You Do Work in a Fuel Tank
TASK 28-10-00-910-002-A
Access to the Fuel Tanks and the Work Areas
TASK 28-25-00-650-001-A
Pressure Defuel
TASK 28-25-00-650-003-A
To Drain Remaining Fuel from the Wing Tanks and the Center Tank
TASK 28-25-00-650-003-A-01
To Drain Remaining Fuel from the Wing Tanks and the Center Tank
TASK 57-27-11-000-002-A
Removal of the Access Panel
3. Job Set-up
Subtask 28-12-41-941-065-A ** ON A/C NOT FOR ALL
A. Safety Precautions
WARNING: BEFORE YOU DO WORK IN OR NEAR A FUEL TANK, MAKE SURE THAT YOU OBEY ALL THE SAFETY PROCEDURES. THIS WILL PREVENT INJURY TO PERSONS AND/OR DAMAGE TO THE AIRCRAFT.
   (1) You must obey the fuel safety procedures when you do work in a fuel tank (Ref. AMM TASK 28-10-00-910-001).
   (2) Put the SAFETY BARRIER(S) in position.
Subtask 28-12-41-650-050-A ** ON A/C NOT FOR ALL
B. Fuel Configuration
   (1) Defuel the applicable fuel tank (Ref. AMM TASK 28-25-00-650-001).
   (2) Drain the remaining fuel from the applicable fuel tank (Ref. AMM TASK 28-25-00-650-003).
Subtask 28-12-41-010-055-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Put the ACCESS PLATFORM 3M (10 FT) in position below the applicable zone 540 or 640.
   (2) Remove the applicable access panels
(Ref. AMM TASK 57-27-11-000-002) and (Ref. AMM TASK 28-10-00-910-002):

     (a) FOR [102QM] (PROTECTOR-OVERPRESSURE, L WING TK)
remove 540JB 540KB

     (b) FOR [103QM] (PROTECTOR-OVERPRESSURE, R WING TK)
remove 640JB 640KB.
4. Procedure
Subtask 28-12-41-020-051-A ** ON A/C NOT FOR ALL
A. Removal of the Overpressure Protector 102QM(103QM)
   (1) Remove the bolts (1).
   (2) Remove the overpressure protector (4).
   (3) Remove and discard the O-ring (3).
[Rev.10 from 2021] 2026.04.02 06:17:09 UTC