Re-activation of the Overpressure Protector - FAA Operators Only
TASK 28-12-00-440-802-A
Re-activation of the Overpressure Protector - FAA Operators Only
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 28-12-00-941-065-A
Subtask 28-12-00-440-052-A
Subtask 28-12-00-942-068-A
[Rev.10 from 2021]
2026.04.02 06:17:08 UTC
Re-activation of the Overpressure Protector - FAA Operators Only
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
1. Reason for the Job- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
NOTE: This procedure is for FAA operators only and is the re-activation procedure for the TASK 28-12-00-040-802.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE |
| No specific | AR | SAFETY BARRIER(S) |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 550CB, 650CB |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 28-12-00-200-001-A | Inspection of the Tank Venting System |
| TASK 28-12-45-000-001-A | Removal of the Panel Assembly |
| TASK 28-12-45-400-002-A | Installation of the Panel Assembly |
Subtask 28-12-00-941-065-A
A. Safety Precautions
(1) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
(2) In the cockpit, put a WARNING NOTICE(S) in position to tell persons not to operate the flight controls.
(3) Put an ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position below the applicable access panel 550CB ( 650CB).
4. Procedure(1) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
(2) In the cockpit, put a WARNING NOTICE(S) in position to tell persons not to operate the flight controls.
(3) Put an ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position below the applicable access panel 550CB ( 650CB).
Subtask 28-12-00-440-052-A
A. Re-activation of the Overpressure Protector 46QM (47QM)
(1) Replace the applicable overpressure protector (Ref. AMM TASK 28-12-45-000-001) and (Ref. AMM TASK 28-12-45-400-002).
(2) Do an inspection of the tank venting system to find the cause of the overpressure protector operation (Ref. AMM TASK 28-12-00-200-001).
(3) Make an entry in the aircraft technical log that the overpressure protector is re-activated.
5. Close-up(1) Replace the applicable overpressure protector (Ref. AMM TASK 28-12-45-000-001) and (Ref. AMM TASK 28-12-45-400-002).
(2) Do an inspection of the tank venting system to find the cause of the overpressure protector operation (Ref. AMM TASK 28-12-00-200-001).
(3) Make an entry in the aircraft technical log that the overpressure protector is re-activated.
Subtask 28-12-00-942-068-A
A. Removal of the Equipment
(1) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(2) Make sure that the work area is clean and clear of tools and other items.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
(5) Remove the SAFETY BARRIERS.
(1) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(2) Make sure that the work area is clean and clear of tools and other items.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
(5) Remove the SAFETY BARRIERS.
Overpressure Protector 46QM (47QM) - Location and Detail