W DOC AIRBUS | AMM A320F

De-activation of the Overpressure Protector - FAA Operators Only


TASK 28-12-00-040-802-A
De-activation of the Overpressure Protector - FAA Operators Only


WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
ZONE: 210
FIN: 46QM
FIN: 47QM
1. Reason for the Job
NOTE: Refer to MMEL 28-12-01-2 Fuel Overpressure Protectors (FAA ONLY).
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE
No specific
AR
SAFETY BARRIER(S)
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
550CB, 650CB
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 28-12-47-200-001-A
Visual Check of NACA Intake for Signs of Blockage
3. Job Set-up
Subtask 28-12-00-941-064-A
A. Safety Precautions
   (1) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
   (2) In the cockpit, put a WARNING NOTICE(S) in position to tell persons not to operate the flight controls.
   (3) Put an ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE below the applicable access panel 550CB ( 650CB).
4. Procedure
Subtask 28-12-00-040-056-A
A. De-activation of the Overpressure Protector 46QM (47QM)
   (1) Do an inspection of the overpressure protector:
     (a) Make sure that you can see the white cross on the burst disk of the applicable overpressure protector.
     (b) If you cannot see the white cross on the burst disk of the applicable overpressure protector, continue as follows:
       1 Do an inspection of the applicable NACA vent intake (Ref. AMM TASK 28-12-47-200-001)
       2 Make an entry in the aircraft technical log that the overpressure protector 46QM (47QM) is disconnected.
5. Close-up
Subtask 28-12-00-942-067-A
A. Removal of the Equipment
   (1) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
   (2) Make sure that the work area is clean and clear of tools and other items.
   (3) Remove the access platform(s).
   (4) Remove the WARNING NOTICE(S).
   (5) Remove the SAFETY BARRIERS.