Installation of the ACT Water Drain Valve
TASK 28-11-47-400-001-A
Installation of the ACT Water Drain Valve
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 28-11-47-860-051-A ** ON A/C NOT FOR ALL
Subtask 28-11-47-420-050-A ** ON A/C NOT FOR ALL
Subtask 28-11-47-860-052-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:17:06 UTC
Installation of the ACT Water Drain Valve
WARNING:
BEFORE YOU DO WORK IN OR NEAR A FUEL TANK, MAKE SURE THAT YOU OBEY ALL THE SAFETY PROCEDURES. THIS WILL PREVENT INJURY TO PERSONS AND/OR DAMAGE TO THE AIRCRAFT.
WARNING:
BE CAREFUL NOT TO GET AIRCRAFT FUEL IN YOUR MOUTH OR IN YOUR EYES.
IF YOU GET FUEL ON YOUR SKIN OR ON YOUR CLOTHES, FLUSH IT IMMEDIATELY WITH WATER.
IF NECESSARY, GET MEDICAL HELP.
AIRCRAFT FUEL IS POISONOUS.
WARNING:
DO NOT GET YOUR CLOTHES SOAKED WITH FUEL.
WARNING:
MAKE SURE THAT YOU HAVE THE CORRECT FIRE FIGHTING EQUIPMENT AVAILABLE.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | WARNING NOTICE(S) |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 12-11-28-650-003-A | Pressure Refuel with Automatic Control |
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 28-00-00-910-001-A | Fuel Safety Procedures |
| TASK 28-10-00-910-001-A | Safety Procedures When You Do Work in a Fuel Tank |
| TASK 28-11-27-000-001-A | Removal of the Additional Center Tank (ACT) |
| TASK 28-11-27-400-001-A | Installation of the Additional Center Tank (ACT) |
| TASK 28-11-37-000-001-A | Removal of the Inner Manhole-Cover ACT |
| TASK 28-11-37-000-004-A | Removal of the Outer Manhole-Cover ACT |
| TASK 28-11-37-400-001-A | Installation of the Inner Manhole-Cover ACT |
| TASK 28-11-37-400-004-A | Installation of the Outer Manhole Cover ACT |
| TASK 28-25-00-650-005-A | To Drain the Remaining Fuel from the Additional Center Tank (ACT) |
Subtask 28-11-47-860-051-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Obey the fuel safety procedures (Ref. AMM TASK 28-00-00-910-001).
(2) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
(3) Make sure that the applicable ACT is fully drained (Ref. AMM TASK 28-25-00-650-005).
(4) Make sure that the WARNING NOTICE(S) are in position on:
(6) Make sure that the applicable ACT Manhole Covers are removed (Ref. AMM TASK 28-11-37-000-004) (Ref. AMM TASK 28-11-37-000-001).
4. Procedure(1) Obey the fuel safety procedures (Ref. AMM TASK 28-00-00-910-001).
(2) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
(3) Make sure that the applicable ACT is fully drained (Ref. AMM TASK 28-25-00-650-005).
(4) Make sure that the WARNING NOTICE(S) are in position on:
- the refuel/defuel control panel 801VU,
- the fuel control panel 40VU,
to tell persons not to operate the refuel/defuel system.
NOTE: To install equipment inside of an ACT, first make sure that the ACT is removed from the aircraft.
(5) Make sure that the applicable ACT is removed from the aircraft (Ref. AMM TASK 28-11-27-000-001). (6) Make sure that the applicable ACT Manhole Covers are removed (Ref. AMM TASK 28-11-37-000-004) (Ref. AMM TASK 28-11-37-000-001).
Subtask 28-11-47-420-050-A ** ON A/C NOT FOR ALL
A. Installation of the ACT Water Drain Valve
(2) Install the water drain valves of the ACT in the workshop.
Subtask 28-11-47-410-057-A ** ON A/C NOT FOR ALL CAUTION:
DO THIS PROCEDURE ONLY IN THE WORKSHOP. IF YOU DO NOT OBEY THIS INSTRUCTION, DAMAGE TO THE BLADDER TANK CAN OCCUR.
(1) Obey the safety procedures when you work in a fuel tank (Ref. AMM TASK 28-10-00-910-001). (2) Install the water drain valves of the ACT in the workshop.
B. Close Access
(1) Install the ACT Manhole Covers (Ref. AMM TASK 28-11-37-400-001) (Ref. AMM TASK 28-11-37-400-004).
(2) Install the ACT in the AFT cargo compartment (Ref. AMM TASK 28-11-27-400-001).
Subtask 28-11-47-790-050-A ** ON A/C NOT FOR ALL (1) Install the ACT Manhole Covers (Ref. AMM TASK 28-11-37-400-001) (Ref. AMM TASK 28-11-37-400-004).
(2) Install the ACT in the AFT cargo compartment (Ref. AMM TASK 28-11-27-400-001).
C. Leak Test
(1) Refuel the ACT (Ref. AMM TASK 12-11-28-650-003).
(2) Examine the connection between the water drain valve and the ACT for leaks.
5. Close-up(1) Refuel the ACT (Ref. AMM TASK 12-11-28-650-003).
(2) Examine the connection between the water drain valve and the ACT for leaks.
NOTE: Leaks are not permitted
Subtask 28-11-47-860-052-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to the serviceable condition.
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the WARNING NOTICE(S).
(3) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001)
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the WARNING NOTICE(S).
(3) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001)
Water Drain Valve of the ACT