Removal of the Additional Center Tank (ACT) Water Drain-Valve
TASK 28-11-47-000-003-A
Removal of the Additional Center Tank (ACT) Water Drain-Valve
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 28-11-47-860-058-A ** ON A/C NOT FOR ALL
Subtask 28-11-47-020-053-C ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:17:06 UTC
Removal of the Additional Center Tank (ACT) Water Drain-Valve
WARNING:
OBEY THE FUEL SAFETY PROCEDURES.
WARNING:
BEFORE YOU DO WORK IN OR NEAR A FUEL TANK, MAKE SURE THAT YOU OBEY ALL THE SAFETY PROCEDURES. THIS WILL PREVENT INJURY TO PERSONS AND/OR DAMAGE TO THE AIRCRAFT.
WARNING:
BE CAREFUL NOT TO GET AIRCRAFT FUEL IN YOUR MOUTH OR IN YOUR EYES.
IF YOU GET FUEL ON YOUR SKIN OR ON YOUR CLOTHES, FLUSH IT IMMEDIATELY WITH WATER.
IF NECESSARY, GET MEDICAL HELP.
AIRCRAFT FUEL IS POISONOUS.
WARNING:
DO NOT GET YOUR CLOTHES SOAKED WITH FUEL.
WARNING:
MAKE SURE THAT YOU HAVE THE CORRECT FIRE FIGHTING EQUIPMENT AVAILABLE.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 150 | AFT CARGO COMPARTMENT FWD PRESS BULKHEAD TO AFT BULKHEAD OF AFT CARGO COMPARTMENT |
| 160 | BULK CARGO COMPARTMENT AFT BULKHEAD OF AFT CARGO COMPARTMENT TO AFT BULKHEAD OF BULK CARGO COMPARTMENT |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 28-00-00-910-001-A | Fuel Safety Procedures |
| TASK 28-25-00-650-005-A | To Drain the Remaining Fuel from the Additional Center Tank (ACT) |
| TASK 28-25-00-869-001-A | Fuel Transfer |
| FOR [226QM1] (VALVE-WATER DRAIN, ACT1) | |
| TASK 28-11-27-000-002-A | Removal of Additional Center Tank No.1 (ACT AFT1) |
| FOR [226QM2] (VALVE-WATER DRAIN, ACT2) | |
| TASK 28-11-27-000-003-A | Removal of the Additional Center Tank No.2 (ACT AFT2) |
Subtask 28-11-47-860-058-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Obey the fuel safety procedures (Ref. AMM TASK 28-00-00-910-001).
(2) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(3) Transfer the fuel from the Additional Center Tank(s) (ACT)(s) to the center tank (Ref. AMM TASK 28-25-00-869-001).
(4) Drain the remaining fuel of the ACT(s) (Ref. AMM TASK 28-25-00-650-005).
(5) On refuel/defuel control panels 801VU and 800VU, fuel control panel 40VU and on ACT control panel 28VU:
(a) Put the WARNING NOTICE(S) in position to tell persons not to operate the refuel/defuel system.
Subtask 28-11-47-010-054-C ** ON A/C NOT FOR ALL (1) Obey the fuel safety procedures (Ref. AMM TASK 28-00-00-910-001).
(2) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(3) Transfer the fuel from the Additional Center Tank(s) (ACT)(s) to the center tank (Ref. AMM TASK 28-25-00-869-001).
(4) Drain the remaining fuel of the ACT(s) (Ref. AMM TASK 28-25-00-650-005).
(5) On refuel/defuel control panels 801VU and 800VU, fuel control panel 40VU and on ACT control panel 28VU:
(a) Put the WARNING NOTICE(S) in position to tell persons not to operate the refuel/defuel system.
B. Get Access
(2) FOR [226QM2] (VALVE-WATER DRAIN, ACT2)
(a) Remove ACT AFT2 (Ref. AMM TASK 28-11-27-000-003).
(3) FOR [226QM1] (VALVE-WATER DRAIN, ACT1)
(a) Remove ACT AFT1 (Ref. AMM TASK 28-11-27-000-002).
4. ProcedureNOTE: To remove the equipment from the inner side of an ACT, it is necessary to remove the ACT from the aircraft.
(1) Remove the applicable ACT from the aft cargo compartment. (2) FOR [226QM2] (VALVE-WATER DRAIN, ACT2)
(a) Remove ACT AFT2 (Ref. AMM TASK 28-11-27-000-003).
(3) FOR [226QM1] (VALVE-WATER DRAIN, ACT1)
(a) Remove ACT AFT1 (Ref. AMM TASK 28-11-27-000-002).
Subtask 28-11-47-020-053-C ** ON A/C NOT FOR ALL
A. Removal of the ACT Water Drain-Valve
CAUTION:
DO THIS PROCEDURE ONLY IN THE WORKSHOP. IF YOU DO NOT OBEY THIS INSTRUCTION, DAMAGE TO THE BLADDER TANK CAN OCCUR.
(1) Send ACT AFT1 and ACT AFT2 to the workshop for the removal of the water drain valves.
Additional Center Tank (ACT) Water Drain-Valve