Removal of the Gravity Fill Cap/Adaptor
TASK 28-11-43-000-001-A
Removal of the Gravity Fill Cap/Adaptor
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 28-11-43-941-051-A ** ON A/C NOT FOR ALL
Subtask 28-11-43-020-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:17:06 UTC
Removal of the Gravity Fill Cap/Adaptor
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
FIN: 42QM ** ON A/C NOT FOR ALL
FIN: 43QM ** ON A/C NOT FOR ALL
FIN: 44QM ** ON A/C NOT FOR ALL
FIN: 45QM ** ON A/C NOT FOR ALL
1. Reason for the JobFIN: 43QM ** ON A/C NOT FOR ALL
FIN: 44QM ** ON A/C NOT FOR ALL
FIN: 45QM ** ON A/C NOT FOR ALL
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE |
| No specific | AR | SAFETY BARRIER(S) |
| 98D28004000000 | 1 | SPANNER-OVERWING FILLER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [42QM] (ADAPTER-OVERWING REFUEL, L) | |
| FOR [44QM] (CAP-OVERWING REFUEL, L) | |
| 540PB | |
| FOR [43QM] (ADAPTER-OVERWING REFUEL, R) | |
| FOR [45QM] (CAP-OVERWING REFUEL, R) | |
| 640PB | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 28-10-00-910-001-A | Safety Procedures When You Do Work in a Fuel Tank |
| TASK 28-10-00-910-002-A | Access to the Fuel Tanks and the Work Areas |
| TASK 28-12-46-000-001-A | Removal of the Overpressure Protector Outlet |
| TASK 28-25-00-650-001-A | Pressure Defuel |
| TASK 28-25-00-650-003-A | To Drain Remaining Fuel from the Wing Tanks and the Center Tank |
| TASK 28-25-00-650-003-A-01 | To Drain Remaining Fuel from the Wing Tanks and the Center Tank |
| TASK 57-27-11-000-002-A | Removal of the Access Panel |
Subtask 28-11-43-941-051-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(2) Put the SAFETY BARRIER(S) in position.
Subtask 28-11-43-650-050-A ** ON A/C NOT FOR ALL WARNING:
BEFORE YOU DO WORK IN OR NEAR A FUEL TANK, MAKE SURE THAT YOU OBEY ALL THE SAFETY PROCEDURES. THIS WILL PREVENT INJURY TO PERSONS AND/OR DAMAGE TO THE AIRCRAFT.
(1) You must obey the fuel safety procedures when you do work in a fuel tank (Ref. AMM TASK 28-10-00-910-001). (2) Put the SAFETY BARRIER(S) in position.
B. Fuel Configuration
(1) Defuel the applicable fuel tank (Ref. AMM TASK 28-25-00-650-001).
(2) Drain the remaining fuel from the applicable fuel tank (Ref. AMM TASK 28-25-00-650-003).
Subtask 28-11-43-010-050-A ** ON A/C NOT FOR ALL (1) Defuel the applicable fuel tank (Ref. AMM TASK 28-25-00-650-001).
(2) Drain the remaining fuel from the applicable fuel tank (Ref. AMM TASK 28-25-00-650-003).
C. Get Access
(1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE below the applicable access panel 540PB(640PB).
(2) Remove the applicable access panel (Ref. AMM TASK 57-27-11-000-002) and (Ref. AMM TASK 28-10-00-910-002):
(a) FOR [42QM] (ADAPTER-OVERWING REFUEL, L), [44QM] (CAP-OVERWING REFUEL, L)
remove 540PB.
(b) FOR [43QM] (ADAPTER-OVERWING REFUEL, R), [45QM] (CAP-OVERWING REFUEL, R)
remove 640PB.
Subtask 28-11-43-010-050-B ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE below the applicable access panel 540PB(640PB).
(2) Remove the applicable access panel (Ref. AMM TASK 57-27-11-000-002) and (Ref. AMM TASK 28-10-00-910-002):
(a) FOR [42QM] (ADAPTER-OVERWING REFUEL, L), [44QM] (CAP-OVERWING REFUEL, L)
remove 540PB.
(b) FOR [43QM] (ADAPTER-OVERWING REFUEL, R), [45QM] (CAP-OVERWING REFUEL, R)
remove 640PB.
C. Get Access
(1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE below the applicable access panel 540PB(640PB).
(2) Remove the applicable access panel (Ref. AMM TASK 28-12-46-000-001) and (Ref. AMM TASK 28-10-00-910-002):
(a) FOR [42QM] (ADAPTER-OVERWING REFUEL, L), [44QM] (CAP-OVERWING REFUEL, L)
remove 540PB.
(b) FOR [43QM] (ADAPTER-OVERWING REFUEL, R), [45QM] (CAP-OVERWING REFUEL, R)
remove 640PB.
4. Procedure(1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE below the applicable access panel 540PB(640PB).
(2) Remove the applicable access panel (Ref. AMM TASK 28-12-46-000-001) and (Ref. AMM TASK 28-10-00-910-002):
(a) FOR [42QM] (ADAPTER-OVERWING REFUEL, L), [44QM] (CAP-OVERWING REFUEL, L)
remove 540PB.
(b) FOR [43QM] (ADAPTER-OVERWING REFUEL, R), [45QM] (CAP-OVERWING REFUEL, R)
remove 640PB.
Subtask 28-11-43-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Gravity Fill Cap/Adaptor
(1) Remove the cap (2) from the adaptor (4).
(2) Remove the lanyard (3) from the locking plate (9) and remove the cap (2).
(3) Remove and discard the cotter-pin (12) from the cap (2) and remove the lanyard (3).
(4) Drill out the rivets (8) from the locking plate (9) and the nut (7) and remove the locking plate (9).
(5) Make sure that you remove all the swarf from the work area.
(6) Remove the nut (7) from the adaptor (4) with the 98D28004000000 SPANNER-OVERWING FILLER.
(7) Remove the insulating gasket (10) and the seal ring (11) from the adaptor (4).
(8) Remove the adaptor (4) from the wing.
(9) Remove and discard the O-rings (5) and (6).
(1) Remove the cap (2) from the adaptor (4).
(2) Remove the lanyard (3) from the locking plate (9) and remove the cap (2).
(3) Remove and discard the cotter-pin (12) from the cap (2) and remove the lanyard (3).
(4) Drill out the rivets (8) from the locking plate (9) and the nut (7) and remove the locking plate (9).
(5) Make sure that you remove all the swarf from the work area.
(6) Remove the nut (7) from the adaptor (4) with the 98D28004000000 SPANNER-OVERWING FILLER.
(7) Remove the insulating gasket (10) and the seal ring (11) from the adaptor (4).
(8) Remove the adaptor (4) from the wing.
(9) Remove and discard the O-rings (5) and (6).
Gravity Fill Cap/Adaptor.