Removal of the Water Drain Valve
TASK 28-11-41-000-002-A
Removal of the Water Drain Valve
Self Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 28-11-41-941-068-A ** ON A/C NOT FOR ALL
Subtask 28-11-41-020-051-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:17:05 UTC
Removal of the Water Drain Valve
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
1. Reason for the Job- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
Self Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE |
| No specific | AR | SAFETY BARRIER(S) |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 28-10-00-910-001-A | Safety Procedures When You Do Work in a Fuel Tank |
| TASK 28-10-00-910-002-A | Access to the Fuel Tanks and the Work Areas |
| TASK 28-25-00-650-001-A | Pressure Defuel |
| TASK 28-25-00-650-003-A | To Drain Remaining Fuel from the Wing Tanks and the Center Tank |
| TASK 28-25-00-650-003-A-01 | To Drain Remaining Fuel from the Wing Tanks and the Center Tank |
| TASK 57-27-11-000-002-A | Removal of the Access Panel |
Subtask 28-11-41-941-068-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(2) Put the SAFETY BARRIER(S) in position.
Subtask 28-11-41-650-069-A ** ON A/C NOT FOR ALL WARNING:
BEFORE YOU DO WORK IN OR NEAR A FUEL TANK, MAKE SURE THAT YOU OBEY ALL THE SAFETY PROCEDURES. THIS WILL PREVENT INJURY TO PERSONS AND/OR DAMAGE TO THE AIRCRAFT.
(1) You must obey the safety procedures when you do work in a fuel tank (Ref. AMM TASK 28-10-00-910-001). (2) Put the SAFETY BARRIER(S) in position.
B. Fuel Configuration
(1) Defuel the applicable wing tank (Ref. AMM TASK 28-25-00-650-001).
(2) Drain the fuel that remains from the applicable wing tank outer cell (Ref. AMM TASK 28-25-00-650-003).
Subtask 28-11-41-010-053-A ** ON A/C NOT FOR ALL (1) Defuel the applicable wing tank (Ref. AMM TASK 28-25-00-650-001).
(2) Drain the fuel that remains from the applicable wing tank outer cell (Ref. AMM TASK 28-25-00-650-003).
C. Get Access
(1) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position below the applicable access panel 540KB(640KB).
(2) Remove the access panel 540KB(640KB) (Ref. AMM TASK 57-27-11-000-002) and (Ref. AMM TASK 28-10-00-910-002).
4. Procedure(1) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position below the applicable access panel 540KB(640KB).
(2) Remove the access panel 540KB(640KB) (Ref. AMM TASK 57-27-11-000-002) and (Ref. AMM TASK 28-10-00-910-002).
Subtask 28-11-41-020-051-A ** ON A/C NOT FOR ALL
A. Removal of the Water Drain Valve
(1) Remove the nuts (4) and the bolts (8) and (9).
(2) Remove the water drain valve (5).
(3) Remove and discard the O-rings (6) and (7).
(4) Loosen the nut (2) then remove the elbow (1).
(5) Remove and discard the O-ring (3).
(1) Remove the nuts (4) and the bolts (8) and (9).
(2) Remove the water drain valve (5).
(3) Remove and discard the O-rings (6) and (7).
(4) Loosen the nut (2) then remove the elbow (1).
(5) Remove and discard the O-ring (3).
Water Drain Valve - Outer Cell