Removal of the Water Drain Valve
TASK 28-11-41-000-001-A
Removal of the Water Drain Valve
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 28-11-41-941-050-A
Subtask 28-11-41-020-050-A
[Rev.10 from 2021]
2026.04.02 06:17:05 UTC
Removal of the Water Drain Valve
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
1. Reason for the Job- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 4M (13 FT) |
| No specific | AR | SAFETY BARRIER(S) |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 28-10-00-910-001-A | Safety Procedures When You Do Work in a Fuel Tank |
| TASK 28-10-00-910-002-A | Access to the Fuel Tanks and the Work Areas |
| TASK 28-12-47-000-001-A | Removal of the NACA Vent Intake |
| TASK 28-25-00-650-003-A | To Drain Remaining Fuel from the Wing Tanks and the Center Tank |
| TASK 28-25-00-650-003-A-01 | To Drain Remaining Fuel from the Wing Tanks and the Center Tank |
Subtask 28-11-41-941-050-A
A. Safety Procedures
(2) Put the SAFETY BARRIER(S) in position.
Subtask 28-11-41-650-067-A WARNING:
BEFORE YOU DO WORK IN OR NEAR A FUEL TANK, MAKE SURE THAT YOU OBEY ALL THE SAFETY PROCEDURES. THIS WILL PREVENT INJURY TO PERSONS AND/OR DAMAGE TO THE AIRCRAFT.
(1) You must obey the safety procedures when you do work in a fuel tank (Ref. AMM TASK 28-10-00-910-001). (2) Put the SAFETY BARRIER(S) in position.
B. Fuel Configuration
(1) Drain all the fuel from the vent surge tank through the water drain valve (Ref. AMM TASK 28-25-00-650-003).
Subtask 28-11-41-010-050-A (1) Drain all the fuel from the vent surge tank through the water drain valve (Ref. AMM TASK 28-25-00-650-003).
C. Get Access
(1) Put the ACCESS PLATFORM 4M (13 FT) below the applicable access panel 550AB(650AB).
(2) Remove the NACA vent intake (Ref. AMM TASK 28-12-47-000-001) and (Ref. AMM TASK 28-10-00-910-002).
4. Procedure(1) Put the ACCESS PLATFORM 4M (13 FT) below the applicable access panel 550AB(650AB).
(2) Remove the NACA vent intake (Ref. AMM TASK 28-12-47-000-001) and (Ref. AMM TASK 28-10-00-910-002).
Subtask 28-11-41-020-050-A
A. Removal of the Water Drain Valve
(1) Remove the nuts (1) and the bolts (4).
(2) Remove the water drain valve (2).
(3) Remove and discard the O-rings (3) and (5).
(1) Remove the nuts (1) and the bolts (4).
(2) Remove the water drain valve (2).
(3) Remove and discard the O-rings (3) and (5).
Water Drain Valve - Vent Surge Tank