Biocidal Preventative Treatment for Aircraft in Long-Term Storage - Using Kathon Biocide With a Metered Injection Rig
TASK 28-11-00-600-010-A-03
Biocidal Preventative Treatment for Aircraft in Long-Term Storage - Using Kathon Biocide With a Metered Injection Rig
1. Reason for the Job
Do this procedure only when an aircraft is put in long-term storage of 30 days or more.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Referenced Information
3. Job Set-up
Subtask 28-11-00-941-113-A
Subtask 28-11-00-860-116-A
Subtask 28-11-00-670-073-A
Subtask 28-11-00-942-119-A
[Rev.9 from 2019]
2026.04.02 06:16:59 UTC
Biocidal Preventative Treatment for Aircraft in Long-Term Storage - Using Kathon Biocide With a Metered Injection Rig
1. Reason for the Job
Do this procedure only when an aircraft is put in long-term storage of 30 days or more.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | METERING EQUIPMENT - BIOCIDE, HAMMONDS FUEL ADDITIVES |
| No specific | 1 | METERING EQUIPMENT - BIOCIDE, LUBRIZOL FUEL ADDITIVES |
| No specific | 1 | METERING EQUIPMENT - BIOCIDE,FLIGHTLINE FUEL ADD.INC. |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.11KBB1) | Antimicrobial Agent-Fuel System Liquid Additive - |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 12-11-28-650-003-A | Pressure Refuel with Automatic Control |
| TASK 28-00-00-910-001-A | Fuel Safety Procedures |
| TASK 28-11-00-600-010-A-02 | Biocidal Preventative Treatment for Aircraft in Long-Term Storage - Using Biobor Biocide With a Metered Injection Rig |
| TASK 28-25-00-650-001-A | Pressure Defuel |
Subtask 28-11-00-941-113-A
WARNING:
OBEY THE FUEL SAFETY PROCEDURES.
A. Safety PrecautionsNOTE: For the equivalent procedure with the use of Biobor, refer to (Ref. AMM TASK 28-11-00-600-010).
(1) You must obey the fuel safety procedures when you do work on the fuel system (Ref. AMM TASK 28-00-00-910-001). B. Aircraft Maintenance Configuration
(1) Defuel the aircraft (Ref. AMM TASK 28-25-00-650-001).
4. Procedure(1) Defuel the aircraft (Ref. AMM TASK 28-25-00-650-001).
NOTE: If you defueled the aircraft before you park it, it is not necessary to defuel the aircraft again.
Subtask 28-11-00-670-073-A
A. Biocidal Preventative Treatment for Aircraft in Long-Term Storage - using Kathon Biocide with a Metered Injection Rig
(6) Disconnect:
5. Close-upCAUTION:
DO NOT USE A LARGE QUANTITY OF KATHON BIOCIDE IN THE FUEL. MORE THAN 100 PPM IS NOT PERMITTED IN:
(1) Put Antimicrobial Agent-Fuel System Liquid Additive - (Material No.11KBB1) into: - THE ENGINES
- THE FUEL TANKS
- THE FUEL UPLIFTED TO THE AIRCRAFT.
- The METERING EQUIPMENT - BIOCIDE, HAMMONDS FUEL ADDITIVES or
- The METERING EQUIPMENT - BIOCIDE, LUBRIZOL FUEL ADDITIVES or
- The METERING EQUIPMENT - BIOCIDE,FLIGHTLINE FUEL ADD.INC..
- The METERING EQUIPMENT - BIOCIDE, HAMMONDS FUEL ADDITIVES or
- The METERING EQUIPMENT - BIOCIDE, LUBRIZOL FUEL ADDITIVES or
- The METERING EQUIPMENT - BIOCIDE,FLIGHTLINE FUEL ADD.INC.
is correctly electrically bonded.
- The METERING EQUIPMENT - BIOCIDE, HAMMONDS FUEL ADDITIVES or
- The METERING EQUIPMENT - BIOCIDE, LUBRIZOL FUEL ADDITIVES or
- The METERING EQUIPMENT - BIOCIDE,FLIGHTLINE FUEL ADD.INC.
to the aircraft.
- The METERING EQUIPMENT - BIOCIDE, HAMMONDS FUEL ADDITIVES or
- The METERING EQUIPMENT - BIOCIDE, LUBRIZOL FUEL ADDITIVES or
- The METERING EQUIPMENT - BIOCIDE,FLIGHTLINE FUEL ADD.INC..
(6) Disconnect:
- The METERING EQUIPMENT - BIOCIDE, HAMMONDS FUEL ADDITIVES or
- The METERING EQUIPMENT - BIOCIDE, LUBRIZOL FUEL ADDITIVES or
- The METERING EQUIPMENT - BIOCIDE,FLIGHTLINE FUEL ADD.INC.
and the tanker from the aircraft.
Subtask 28-11-00-942-119-A
A. Removal of Equipment
(1) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(1) Remove the ground support and maintenance equipment, the special and standard tools and all other items.