W DOC AIRBUS | AMM A320F

Removal of the SEC


TASK 27-94-34-000-001-A
Removal of the SEC


ZONE: 121
ZONE: 127
ZONE: 128
FIN: 1CE1
FIN: 1CE2
FIN: 1CE3
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
121
AVIONICS COMPARTMENT
127
REAR AVIONIC COMPARTMENT
128
REAR AVIONIC COMPARTMENT
822
FOR [1CE1] (SEC-1)
FOR [1CE2] (SEC-2)
824
FOR [1CE3] (SEC-3)
811
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 31-32-00-860-006-A
Procedure to Get Access to the SYSTEM REPORT/TEST F/CTL Page
3. Job Set-up
Subtask 27-94-34-810-050-A
A. Trouble Shooting Data
   (1) You can print the Trouble Shooting Data (TSD) as follows:
  • get access to the SYSTEM/REPORT/TEST (Ref. AMM TASK 31-32-00-860-006).
  • on this page, push the line key adjacent to the EFCS1 and/or EFCS2 indication.
  • on this page, push the line key adjacent to the LAST LEG REPORT indication.
  • on this page, push the line key adjacent to the failure(s) to get the TROUBLE SHOOTING DATA page.
  • print the TROUBLE SHOOTING DATA page.
Subtask 27-94-34-010-050-A
B. Get Access
   (1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 824, 811 and 822.
   (2) Open the access door:
     (a) FOR [1CE1] (SEC-1), [1CE2] (SEC-2)
824
     (b) FOR [1CE3] (SEC-3)
811
     (c) For battery power center 105VU 822.
   (3) On the battery power center 105VU:
  • Loosen the two screws and remove the protective cover
Subtask 27-94-34-865-050-A
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 1CE1 (SEC1)
49VUFLIGHT CONTROLS/SEC1/NORM/SPLY21CE1B08
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/SEC1/NORM/SPLY21CE1B03
** ON A/C ALL
105VUFLT CTL/SEC1/STBY SPLY22CEB01
FOR FIN: 1CE2 (SEC2)
121VUFLIGHT CONTROLS/SEC2/SPLY21CE2Q18
FOR FIN: 1CE3 (SEC3)
121VUFLIGHT CONTROLS/SEC3/SPLY21CE3Q19
4. Procedure
Subtask 27-94-34-020-050-A
A. Removal of the SEC
   (1) Loosen the knurled nuts (4).
   (2) Lower the nuts (4).
   (3) Pull the SEC (1) on its rack (3) to disconnect the electrical connectors (2).
   (4) Remove the SEC (1).
   (5) Put CAP - BLANKING on the disconnected electrical connectors (2).