W DOC AIRBUS | AMM A320F

Removal of the ELAC


TASK 27-93-34-000-001-A
Removal of the ELAC


ZONE: 127
ZONE: 128
FIN: 2CE1
FIN: 2CE2
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
127
REAR AVIONIC COMPARTMENT
128
REAR AVIONIC COMPARTMENT
822, 824
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 31-32-00-860-006-A
Procedure to Get Access to the SYSTEM REPORT/TEST F/CTL Page
3. Job Set-up
Subtask 27-93-34-810-050-A
A. Trouble Shooting Data
   (1) You can print the Trouble Shooting Data (TSD) as follows:
  • get access to the SYSTEM/REPORT/TEST (Ref. AMM TASK 31-32-00-860-006).
  • on this page, push the line key adjacent to the EFCS1 and/or EFCS2 indication.
  • on this page, push the line key adjacent to the LAST LEG REPORT indication.
  • on this page, push the line key adjacent to the failure(s) to get the TROUBLE SHOOTING DATA page.
  • print the TROUBLE SHOOTING DATA page.
Subtask 27-93-34-010-050-A
B. Get Access
   (1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 822.
   (2) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 824 in zone 128.
   (3) Open the access doors 822 and 824.
   (4) On the battery power center 105VU:
  • loosen the two screws and remove the protective cover.
Subtask 27-93-34-865-050-A
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 2CE1 (ELAC1)
49VUFLIGHT CONTROLS/ELAC1/NORM/SPLY15CE1B11
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/ELAC1/NORM/SPLY15CE1B06
** ON A/C ALL
105VUFLT CTL/ELAC1/STBY SPLY16CE1A01
FOR FIN: 2CE2 (ELAC2)
105VUFLIGHT CONTROLS/ELAC2/STBY SPLY16CE2A02
121VUFLIGHT CONTROLS/ELAC2/NORM/SPLY15CE2R20
4. Procedure
Subtask 27-93-34-020-050-A
A. Removal of the ELAC
   (1) Loosen the nuts (4).
   (2) Lower the nuts (4).
   (3) Pull the ELAC (1) on its rack (3) to disconnect the electrical connectors (2).
   (4) Remove the ELAC (1).
   (5) Put CAP - BLANKING on the disconnected electrical connectors (2).
[Rev.10 from 2021] 2026.03.31 23:59:30 UTC