Installation of the Pushbutton Switch-Takeover and Priority
TASK 27-92-41-400-011-A
Installation of the Pushbutton Switch-Takeover and Priority
Self Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Expendable Parts
E. Referenced Information
3. Job Set-up
Subtask 27-92-41-860-059-A
Subtask 27-92-41-420-060-A
Subtask 27-92-41-410-062-A
[Rev.10 from 2021]
2026.03.31 23:59:16 UTC
Installation of the Pushbutton Switch-Takeover and Priority
NOTE: This task is not applicable for the new-generation side-stick unit. For the new-generation side-stick unit, refer to the procedure (Ref. AMM TASK 27-92-41-400-803). To know if the side-stick installed on the aircraft is a new-generation side-stick unit, refer to the procedure (Ref. AMM TASK 27-92-41-860-801).
1. Reason for the JobSelf Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| DMC519 | 1 | ELECTRICIAN SERVICE TOOL KIT |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.05BAA1) | Threadlocking Adhesive-- Low strength - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 211 | COCKPIT |
| 212 | COCKPIT |
| 822 |
| FIG.ITEM | DESIGNATION | IPC-CSN |
|---|---|---|
| 121 | O-RING | AIPC 27-92-41-02-100 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 27-92-41-400-006-A | Installation of the Control Handle |
Subtask 27-92-41-860-059-A
A. Aircraft Maintenance Configuration
(1) Make sure that the ground service network is energized (Ref. AMM TASK 24-42-00-861-001).
(2) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position at the access door 822.
(3) Make sure that the access door 822 is open.
(4) On the battery power center 105VU:
4. Procedure(1) Make sure that the ground service network is energized (Ref. AMM TASK 24-42-00-861-001).
(2) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position at the access door 822.
(3) Make sure that the access door 822 is open.
(4) On the battery power center 105VU:
- make sure that the protective cover is removed.
Subtask 27-92-41-420-060-A
A. Installation of the Pushbutton Switch (8CE1,8CE2)
(1) Clean the component interfaces and the adjacent area.
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Install the new AIPC 27-92-41-02-100 O-RING (121) in its housing.
(4) If you install a new pushbutton switch, you must install a pin contact at the end of each wire.
(5) Install the pushbutton switch (120).
(6) Connect the cables of the pushbutton switch (120) to the electrical connectors (122) and (123) with the extraction/insertion tool P/N M81969/14.01 from the DMC519 ELECTRICIAN SERVICE TOOL KIT.
(7) Put the electrical connectors (122) and (123) in position.
(8) Apply Threadlocking Adhesive-- Low strength - (Material No.05BAA1) on the threads of the screws (124).
(9) Install the screws (124) and tighten them.
5. Close-up(1) Clean the component interfaces and the adjacent area.
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Install the new AIPC 27-92-41-02-100 O-RING (121) in its housing.
(4) If you install a new pushbutton switch, you must install a pin contact at the end of each wire.
(5) Install the pushbutton switch (120).
(6) Connect the cables of the pushbutton switch (120) to the electrical connectors (122) and (123) with the extraction/insertion tool P/N M81969/14.01 from the DMC519 ELECTRICIAN SERVICE TOOL KIT.
(7) Put the electrical connectors (122) and (123) in position.
(8) Apply Threadlocking Adhesive-- Low strength - (Material No.05BAA1) on the threads of the screws (124).
(9) Install the screws (124) and tighten them.
Subtask 27-92-41-410-062-A
Pushbutton Switch