Installation of the Dampers
TASK 27-92-41-400-003-A
Installation of the Dampers
Self Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Expendable Parts
D. Referenced Information
3. Job Set-up
Subtask 27-92-41-860-057-A
Subtask 27-92-41-420-052-A
Subtask 27-92-41-080-052-A Subtask 27-92-41-410-052-A
[Rev.10 from 2021]
2026.03.31 23:59:05 UTC
Installation of the Dampers
WARNING:
MAKE SURE THAT THE SIDE STICK ASSEMBLY STAYS IN THE VERTICAL POSITION DURING THE MAINTENANCE PROCEDURES.
IF NOT THERE IS A RISK OF SKYDROL LEAKAGE.
SKYDROL CAN CAUSE INJURY AND/OR DAMAGE.
NOTE: This task is not applicable for the new-generation side-stick unit. For the new-generation side-stick unit, refer to the procedure (Ref. AMM TASK 27-92-41-400-802). To know if the side-stick installed on the aircraft is a new-generation side-stick unit, refer to the procedure (Ref. AMM TASK 27-92-41-860-801).
1. Reason for the JobSelf Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 211 | COCKPIT |
| 212 | COCKPIT |
| 822 |
| FIG.ITEM | DESIGNATION | IPC-CSN |
|---|---|---|
| 50 | COTTER PINS | AIPC 27-92-41-01-080 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 27-92-41-000-001-A | Removal of the Side Stick Assembly |
| TASK 27-92-41-400-001-A | Installation of the Side Stick Assembly |
Subtask 27-92-41-860-057-A
A. Aircraft Maintenance Configuration
(1) Make sure that the ground service network is energized (Ref. AMM TASK 24-42-00-861-001).
(2) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position at the access door 822.
(3) Make sure that the access door 822 is open.
(4) On the battery power center 105VU:
4. Procedure(1) Make sure that the ground service network is energized (Ref. AMM TASK 24-42-00-861-001).
(2) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position at the access door 822.
(3) Make sure that the access door 822 is open.
(4) On the battery power center 105VU:
- make sure that the protective cover is removed.
Subtask 27-92-41-420-052-A
A. Installation of the Side Stick Damper
(1) Remove the string from the damper (55).
(2) Clean the component interfaces and the adjacent area.
(3) Do an inspection of the component interfaces and the adjacent area.
(4) Install the damper (55) on the side stick assembly and the bolts (54).
(5) Install the washers (52), the nuts (51) and tighten.
(6) Install the new AIPC 27-92-41-01-080 COTTER PINS (50) on the nuts (51).
5. Close-up(1) Remove the string from the damper (55).
(2) Clean the component interfaces and the adjacent area.
(3) Do an inspection of the component interfaces and the adjacent area.
(4) Install the damper (55) on the side stick assembly and the bolts (54).
(5) Install the washers (52), the nuts (51) and tighten.
(6) Install the new AIPC 27-92-41-01-080 COTTER PINS (50) on the nuts (51).
Subtask 27-92-41-080-052-A Subtask 27-92-41-410-052-A
Dampers