NOTE: This task is not applicable for the new-generation side-stick unit. For the new-generation side-stick unit, refer to the procedure (Ref. AMM TASK 27-92-41-000-803). To know if the side-stick installed on the aircraft is a new generation side-stick unit, refer to the procedure (Ref. AMM TASK 27-92-41-860-801).
FIN: 11RN ** ON A/C NOT FOR ALL
FIN: 12RN ** ON A/C NOT FOR ALL
1. Reason for the Job
To remove the radio PTT switch without removal of the side stick control-handle. This alternative procedure uses splices.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
DMC519
1
ELECTRICIAN SERVICE TOOL KIT
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
822
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
ESPM 2043130
ESPM 2048250
ESPM 2056420
3. Job Set-up
Subtask 27-92-41-861-064-A
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 27-92-41-010-084-A
B. Get Access
   (1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 822.
   (2) Open the access door 822.
   (3) On the battery power center 105VU:
  • loosen the two screws and remove the protective cover.
Subtask 27-92-41-865-074-A
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/ELAC1/NORM/SPLY15CE1B11
49VUFLIGHT CONTROLS/SEC1/NORM/SPLY21CE1B08
** ON A/C NOT FOR ALL
49VUCOM/AUDIO/ACP/F/O5RNG07
** ON A/C NOT FOR ALL
49VUCOM/AUDIO/ACP/CAPT4RNG06
** ON A/C NOT FOR ALL
49VUCOM/ACP F/O/BITE/ INT 2 AUDIO/3&5 OCCPNT5RNG07
** ON A/C NOT FOR ALL
49VUCOM/ACP CAPT/SELCAL/INT 1 AUDIO/AVNCS4RNG06
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/ELAC1/NORM/SPLY15CE1B06
49VUFLIGHT CONTROLS/SEC1/NORM/SPLY21CE1B03
** ON A/C ALL
105VUFLIGHT CONTROLS/ELAC2/STBY SPLY16CE2A02
105VUFLT CTL/ELAC1/STBY SPLY16CE1A01
105VUFLT CTL/SEC1/STBY SPLY22CEB01
** ON A/C NOT FOR ALL
121VUAUTO FLT/STICK/LOCK13CAN16
** ON A/C ALL
121VUFLIGHT CONTROLS/SEC3/SPLY21CE3Q19
121VUFLIGHT CONTROLS/SEC2/SPLY21CE2Q18
121VUFLIGHT CONTROLS/ELAC2/NORM/SPLY15CE2R20
** ON A/C NOT FOR ALL
121VUAUTO FLT/STICK/LOCK13CAN18
4. Procedure
Subtask 27-92-41-020-065-A
A. Removal of the Radio PTT Switch (11RN,12RN) (Alternative Procedure)
   (1) Remove the screws (100). Remove the cover plate (101).
   (2) Remove the blanking plug (113), the nut (112), the washer (111) and the trigger(110).
   (3) Remove the nut (109), the washer (103).
   (4) Remove the PTT switch (105) with the washer (102) from the side stick control-handle.
   (5) Do a visual check of the PTT switch wires to see if there are splices already installed:
     (a) If there are splices installed:
       1 Use the extraction/insertion tool P/N M81969/14.01 from the DMC519 ELECTRICIAN SERVICE TOOL KIT ESPM 2056420 to disconnect the PTT switch wires from the splices.
       2 Remove the PTT switch (105).
     (b) If there is no splice installed:
       1 Cut the wires of the PTT switch as follows:
         a Before you cut the wires, make sure that the two identification-labels stay on the wires, on the control-handle side.
         b On the two wires, measure 40 mm distance "A" from the studs of the PTT switch and make a mark on each wire.
         c Cut the two wires at these marks.
       2 Remove the PTT switch (105).
       3 Install a pin contact NSA937910EA2200 ESPM 2048250 at the end of each wire on the control-handle side.
       4 On the control-handle side, use the extraction/insertion tool P/N M81969/14.01 from the DMC519 ELECTRICIAN SERVICE TOOL KIT ESPM 2056420 to connect the two wires to splices NSA936830-22 ESPM 2043130.