W DOC AIRBUS | AMM A320F

Removal of the Flap Track 1 to 4 Actuators


TASK 27-54-49-000-008-A
Removal of the Flap Track 1 to 4 Actuators


WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
CAUTION: BE CAREFUL WHEN YOU DO MAINTENANCE TASKS ON THE WING TRAILING EDGE:
  • DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE RACEWAYS.
  • DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE INSTALLATIONS.
  • MAKE SURE THAT THE ELECTRICAL CABLES ARE INSTALLED CORRECTLY. INCORRECT INSTALLATION CAN CAUSE DAMAGE.
ZONE: 193
ZONE: 194
ZONE: 570
ZONE: 670
FIN: 6205CM
FIN: 6211CM
FIN: 6221CM
FIN: 6233CM
FIN: 6255CM
FIN: 6261CM
FIN: 6271CM
FIN: 6283CM
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
No specific
AR
CLAMPS
No specific
AR
SAFETY BARRIER(S)
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
98D27508002000
4
SET-CARRIAGE STOP,FLAP
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
193
UPPER WING FAIRING SLIDE STOWAGE
194
UPPER WING FAIRING SLIDE STOWAGE
570
AFT SECTION OF L WING & TE FIXED STRUCT
670
AFT SECTION OF R WING & TE FIXED STRUCT
193AB, 193BB, 194AB, 194BB, 573AB, 573BB, 573CB, 575AB, 575BB, 575CB, 575DB, 575EB, 575FB, 575GB, 673AB, 673BB, 673CB, 675AB, 675BB, 675CB, 675DB, 675EB, 675FB, 675GB
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 27-50-00-860-801-A
Readout of the Flap Position Pickoff Unit (PPU) Data
TASK 27-50-00-866-008-A
Extension of the Flaps on the Ground
TASK 27-50-00-866-008-A-01
Extension of the Flaps/Slats on the Ground
TASK 27-51-18-000-001-A
Removal of the Asymmetry-Position Pick-Off Unit
TASK 27-54-49-000-001-A
Removal of the Flap Track 1 Actuator
TASK 27-54-49-000-002-A
Removal of the Flap Track 2 Actuator
TASK 27-54-49-000-003-A
Removal of the Flap Track 3 Actuator
TASK 27-54-49-000-004-A
Removal of the Flap Track 4 Actuator
TASK 27-60-00-866-002-A
Extension-Retraction of the Spoilers for Maintenance
TASK 32-00-00-481-001-A
Installation of the Safety Devices on the Landing Gears
TASK 32-12-00-010-001-A
Open the Main Gear Doors for Access
TASK 53-35-11-000-001-A
Removal of the Wing-to-Fuselage Fairings
TASK 57-51-37-000-002-A
Removal of the Access Panels 571AB(671AB), 573AB(673AB), 573BB(673BB), 573CB(673CB), 573EB(673EB)
TASK 57-51-37-000-004-A
Removal of the Access Panels 575AB(675AB), 575BB(675BB), 575CB(675CB), 575DB(675DB), 575EB(675EB), 575FB(675FB), 575GB(675GB), 575HB(675HB)
3. Job Set-up
Subtask 27-54-49-941-076-A
A. Safety Precautions
   (1) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
   (2) Put the WARNING NOTICE(S) in position to tell persons not to operate the flaps.
   (3) Put a WARNING NOTICE(S) in position to tell persons not to operate the landing gear doors.
   (4) Make sure that the ground safety locks are installed on the landing gear (Ref. AMM TASK 32-00-00-481-001).
Subtask 27-54-49-860-064-A
B. Aircraft Maintenance Configuration
WARNING: MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS SURFACES ARE CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
   (1) Extend the flaps to position 3 (Ref. AMM TASK 27-50-00-866-008).
   (2) Make sure that the 98D27803000000 LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION is on the flap/slat control lever in the cockpit.
   (3) Put the WARNING NOTICE(S) in position to tell persons not to operate the flaps.
   (4) Extend the No. 1 to No. 5 spoilers (Ref. AMM TASK 27-60-00-866-002).
   (5) Make sure that a 98D27604000000 COLLAR-SAFETY, SPOILER or 98D27604004000 COLLAR SAFETY SPOILER is on the piston rod of each servo-control.
4. Procedure
Subtask 27-54-49-740-068-A
A. Readout of the PPU Data
   (1) Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
   (2) Do the readout of the PPU data (Ref. AMM TASK 27-50-00-860-801).
NOTE: Airbus recommends to do the readout and recording of the PPU angles before the maintenance action.
In case of a loss of the torque shaft fixture you can put the flap transmission system back to the initial condition (without a complete adjustment of the system).
   (3) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
Subtask 27-54-49-865-089-A
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/FLP/CTL AND MONG/SYS16CVB07
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/FLP/CTL AND MONG/SYS16CVB02
** ON A/C ALL
121VUFLIGHT CONTROLS/FLP/CTL AND/MONG/SYS28CVQ21
Subtask 27-54-49-010-065-A
C. Get Access
   (1) Open the applicable MLG door (Ref. AMM TASK 32-12-00-010-001).
   (2) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position below the applicable access panels.
   (3) Remove the applicable access panels:
     (a) For the LH wing, remove:
     (b) For the RH wing, remove:
Subtask 27-54-49-020-063-A
D. Preparation for Removal of the Flap Track 1 thru 4 Actuators
   (1) Hold the trailing edges of the inboard and outboard flaps on the supports.
   (2) Use the 98D27508002000 SET-CARRIAGE STOP,FLAP or the CLAMPS to hold the flap carriages in position.
NOTE: This is to make sure that the flap carriages do not move.
   (3) Measure and record dimension A between the actuator lever and its stop face.
   (4) Remove the Asymmetry Position Pick-Off Unit (APPU) from the flap track 4 actuator (Ref. AMM TASK 27-51-18-000-001).
NOTE: An APPU can be removed/installed when the flap/slat system is not at zero if:
  • The same APPU is installed and its position has not changed
  • No movement of the flap/slat system is permitted during the time the APPU is removed.
NOTE: The unit will be locked in the extended position and must not be adjusted.
Subtask 27-54-49-020-062-A
E. Removal of the Flap Track 1 to 4 Actuators
   (1) Remove the flap track 1 to 4 actuators in sequence (Ref. AMM TASK 27-54-49-000-001), (Ref. AMM TASK 27-54-49-000-002), (Ref. AMM TASK 27-54-49-000-003) and (Ref. AMM TASK 27-54-49-000-004).
[Rev.10 from 2021] 2026.03.31 23:54:02 UTC