W DOC AIRBUS | AMM A320F

Installation of the Torque Shaft


TASK 27-54-45-400-005-A
Installation of the Torque Shaft


WARNING: MAKE SURE THAT THE FLIGHT CONTROL SAFETY-LOCKS AND THE WARNING NOTICES ARE IN POSITION.
WARNING: MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
CAUTION: BE CAREFUL WHEN YOU DO MAINTENANCE TASKS ON THE WING TRAILING EDGE:
  • DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE RACEWAYS.
  • DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE INSTALLATIONS.
  • MAKE SURE THAT THE ELECTRICAL CABLES ARE INSTALLED CORRECTLY. INCORRECT INSTALLATION CAN CAUSE DAMAGE.
FIN: 6210CM
FIN: 6260CM
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
No specific
AR
SAFETY BARRIER(S)
No specific
AR
WARNING NOTICE(S)
No specific
Torque wrench: range to between 1.24 and 1.02 m.daN (109.73 and 90.27 lbf.in ) T
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.03FDB1)
Mineral Oil base Grease-Anti-Fretting Paste -
(Material No.08BAA9)
Non Aqueous Cleaner-General - -
(Material No.12ACC1)
Corrosion Preventive Compound-Heavy Duty Soft Film -
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [6210CM] (FLAP XMSN TORQUE SHAFT)
573AB
FOR [6260CM] (FLAP XMSN TORQUE SHAFT)
673AB
 D. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
3
NUTS
AIPC 27-54-45-05-010
9
NUTS
AIPC 27-54-45-05-010
 E. Referenced Information
REFERENCE
DESIGNATION
TASK 27-50-00-000-003-A
Removal of the Lock-Torque Shaft - Flaps and Slats (98D27504030001)
TASK 27-50-00-400-003-A
Installation of the Lock-Torque Shaft - Flaps and Slats (98D27504030001)
TASK 27-50-00-866-008-A
Extension of the Flaps on the Ground
TASK 27-50-00-866-008-A-01
Extension of the Flaps/Slats on the Ground
TASK 27-50-00-866-009-A
Retraction of the Flaps on the Ground
TASK 27-50-00-866-009-A-01
Retraction of the Flaps/Slats on the Ground
TASK 27-54-00-710-001-A
Operational Test of the Flap System
TASK 57-51-37-000-002-A
Removal of the Access Panels 571AB(671AB), 573AB(673AB), 573BB(673BB), 573CB(673CB), 573EB(673EB)
TASK 57-51-37-400-002-A
Installation of the Access Panels 571AB(671AB), 573AB(673AB), 573BB(673BB), 573CB(673CB), 573EB(673EB)
3. Job Set-up
Subtask 27-54-45-941-081-A
A. Safety Precautions
   (1) Make sure that the SAFETY BARRIER(S) are in position.
   (2) Make sure that the WARNING NOTICE(S) is in position to tell persons not to operate the flap/slat controls.
Subtask 27-54-45-860-067-A
B. Aircraft Maintenance Configuration
WARNING: MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS SURFACES ARE CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
   (1) Make sure that the flaps are fully extended (Ref. AMM TASK 27-50-00-866-008).
   (2) Make sure that the 98D27803000000 LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION is on the flap/slat control lever on panel 114VU.
   (3) Make sure that the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE is in the applicable position.
   (4) Make sure that the applicable access panel is removed (Ref. AMM TASK 57-51-37-000-002):
     (a) FOR [6210CM] (FLAP XMSN TORQUE SHAFT)
if necessary remove 573AB
     (b) FOR [6260CM] (FLAP XMSN TORQUE SHAFT)
if necessary remove 673AB.
   (5) Make sure that the 98D27504030001 LOCK-TORQUE SHAFT (FLAPS AND SLATS) WITH CLAMP-PIVOT is installed on the flap torque shaft (Ref. AMM TASK 27-50-00-400-003), outboard of the removed component.
Subtask 27-54-45-865-071-A
C. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/FLP/CTL AND MONG/SYS16CVB07
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/FLP/CTL AND MONG/SYS16CVB02
** ON A/C ALL
121VUFLIGHT CONTROLS/FLP/CTL AND/MONG/SYS28CVQ21
4. Procedure
Subtask 27-54-45-420-067-A Subtask 27-54-45-420-054-A
B. Installation of the Torque Shaft
NOTE: The torque shaft (2) can be installed with the universal joint (7) orientated to the line gear box or to the flap track 2 actuator.
NOTE: These procedures are almost the same. The instalation of the torque shaft (2) installed with the universal joint (7) orientated to the line gear box is given.
   (1) Put the retaining ring (5) temporarily in position on the shaft of the universal joint (7).
   (2) Install the universal joint (7) in the line gear box 6209CM(6259CM), and attach it with the pin (6) and the retaining ring (5).
   (3) Install the universal joint (1) and align its flange with the flange of the universal joint (7).
   (4) Install the torque shaft (2) and attach it with the bolts (4) and (8) and the nuts (3) and (9).
   (5) TORQUE the nuts (3) and (9) to between 1.24 and 1.02 m.daN (109.73 and 90.27 lbf.in ) T.
   (6) Make sure that:
  • You cannot see the spline engagement groove at the movable joint.
  • The dimension A is a minimum of 6.5 mm (0.256 in.) at the movable joint.
   (7) Remove the
98D27504030001 LOCK-TORQUE SHAFT (FLAPS AND SLATS) WITH CLAMP-PIVOT (Ref. AMM TASK 27-50-00-000-003).
Subtask 27-54-45-916-054-A
C. Application of Special Materials
   (1) Apply a layer of Corrosion Preventive Compound-Heavy Duty Soft Film - (Material No.12ACC1) to:
  • The nuts (3) and (9)
  • The bolts (4) and (8)
  • The flanges of the universal joints (1) and (7)
  • The flanges of the torque shaft (2).
Subtask 27-54-45-410-076-A
D. Close Access
   (1) Remove the access platform(s).
Subtask 27-54-45-865-072-A
E. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/FLP/CTL AND MONG/SYS16CVB07
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/FLP/CTL AND MONG/SYS16CVB02
** ON A/C ALL
121VUFLIGHT CONTROLS/FLP/CTL AND/MONG/SYS28CVQ21
Subtask 27-54-45-710-054-A
F. Operational Test of the Flap System
WARNING: MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS SURFACES ARE CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
   (1) Remove the 98D27803000000 LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION from the flap/slat control lever.
   (2) Retract the flaps fully (Ref. AMM TASK 27-50-00-866-009).
   (3) Do an operational test of the flap system (Ref. AMM TASK 27-54-00-710-001). Make sure that the operation of the torque shafts is satisfactory.
5. Close-up
Subtask 27-54-45-410-054-A
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Install the applicable access panel (Ref. AMM TASK 57-51-37-400-002):
     (a) FOR [6210CM] (FLAP XMSN TORQUE SHAFT)
install 573AB
     (b) FOR [6260CM] (FLAP XMSN TORQUE SHAFT)
install 673AB.
Subtask 27-54-45-942-054-A
B. Removal of Equipment
   (1) Remove the safety barriers.
   (2) Remove the WARNING NOTICE(S).
   (3) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
[Rev.10 from 2021] 2026.03.31 23:53:28 UTC