W DOC AIRBUS | AMM A320F

Installation of the Proximity-Sensors of the Interconnecting Strut


TASK 27-51-15-400-002-A
Installation of the Proximity-Sensors of the Interconnecting Strut


WARNING: MAKE SURE THAT THE FLIGHT CONTROL SAFETY-LOCKS AND THE WARNING NOTICES ARE IN POSITION.
WARNING: MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
FIN: 37CV
FIN: 38CV
FIN: 39CV
FIN: 40CV
1. Reason for the Job
To give ATA reference to agree with CFDS message.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
SAFETY BARRIER(S)
No specific
AR
WARNING NOTICE(S)
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 27-51-44-400-002-A
Installation of the Proximity-Sensor of the Interconnecting Strut
3. Job Set-up
Subtask 27-51-15-941-051-A
A. Safety Precautions
   (1) Make sure that the SAFETY BARRIER(S) are in position.
   (2) Make sure that the WARNING NOTICE(S) is in position to tell persons not to operate the flight controls.
4. Procedure
Subtask 27-51-15-420-050-A
A. Install the Proximity Sensor
   (1) Install the applicable proximity sensor (Ref. AMM TASK 27-51-44-400-002).
5. Close-up
Subtask 27-51-15-942-050-A
A. Removal of Equipment
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Remove the safety barriers.
   (3) Remove the WARNING NOTICE(S).
   (4) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
[Rev.10 from 2021] 2026.03.31 23:52:29 UTC