Removal of the Proximity-Sensors of the Interconnecting Strut
TASK 27-51-15-000-002-A
Removal of the Proximity-Sensors of the Interconnecting Strut
To give ATA reference to agree with CFDS message.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 27-51-15-941-050-A
Subtask 27-51-15-020-050-A
[Rev.10 from 2021]
2026.03.31 23:52:28 UTC
Removal of the Proximity-Sensors of the Interconnecting Strut
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
1. Reason for the JobTo give ATA reference to agree with CFDS message.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | SAFETY BARRIER(S) |
| No specific | AR | WARNING NOTICE(S) |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 27-51-44-000-002-A | Removal of the Proximity-Sensor of the Interconnecting Strut |
Subtask 27-51-15-941-050-A
A. Safety Precautions
(1) Put the SAFETY BARRIER(S) in position.
(2) Put a WARNING NOTICE(S) in position to tell persons not to operate the flight controls.
4. Procedure(1) Put the SAFETY BARRIER(S) in position.
(2) Put a WARNING NOTICE(S) in position to tell persons not to operate the flight controls.
Subtask 27-51-15-020-050-A
A. Remove the Proximity Sensor
(1) Remove the applicable proximity sensor (Ref. AMM TASK 27-51-44-000-002).
(1) Remove the applicable proximity sensor (Ref. AMM TASK 27-51-44-000-002).