Replacement of the Filter Assy in Valve Block of the THS Actuator
TASK 27-44-51-960-001-A
Replacement of the Filter Assy in Valve Block of the THS Actuator
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Expendable Parts
E. Referenced Information
3. Job Set-up
Subtask 27-44-51-010-065-A
Subtask 27-44-51-020-054-A
Subtask 27-44-51-410-064-A
[Rev.10 from 2021]
2026.03.31 23:51:18 UTC
Replacement of the Filter Assy in Valve Block of the THS Actuator
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS SURFACES ARE CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 310
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.03LDA1) | Grease-Hydraulic Systems - - |
| (Material No.08BBB1) | Non Aqueous Cleaner-- Petroleum Based - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 310 | FUSLG TAIL SECTION AFT OF AFT PRESS BHD |
| 312AR |
| FIG.ITEM | DESIGNATION | IPC-CSN |
|---|---|---|
| 2 | PACKING | AIPC 27-44-55-01-020 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 27-41-00-720-001-A | Functional Test of the THS-Actuator Overtravel Related to the Mechanical Indicator |
| TASK 27-44-51-210-004-A | Check Oil Level of THS Actuator Gearbox |
| TASK 29-00-00-864-001-A | Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action |
| TASK 29-00-00-910-002-A | Safety Procedures of the Hydraulic System |
| TASK 29-14-00-614-001-A | Depressurization of the Hydraulic Reservoirs |
Subtask 27-44-51-010-065-A
A. Get Access
(1) Put the ACCESS PLATFORM 6M (20 FT) - ADJUSTABLE in position.
(2) Open the access door 312AR.
Subtask 27-44-51-860-065-A (1) Put the ACCESS PLATFORM 6M (20 FT) - ADJUSTABLE in position.
(2) Open the access door 312AR.
B. Aircraft Maintenance Configuration
(3) Make sure that the Blue hydraulic system is depressurized and put it in the maintenance configuration.
(Ref. AMM TASK 29-00-00-864-001).
(4) Depressurize the reservoirs of the Green and Yellow hydraulic systems.
(Ref. AMM TASK 29-14-00-614-001).
(5) Put the WARNING NOTICE(S) in position to tell persons not to pressurize the Green, the Yellow and the Blue hydraulic systems:
Subtask 27-44-51-865-063-A WARNING:
OBEY THE HYDRAULIC SAFETY PROCEDURES.
(1) Obey the hydraulic safety procedures (Ref. AMM TASK 29-00-00-910-002)WARNING:
MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS SURFACES ARE CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
(2) Depressurize the Green and Yellow hydraulic systems and put them in the maintenance configuration (Ref. AMM TASK 29-00-00-864-001). (3) Make sure that the Blue hydraulic system is depressurized and put it in the maintenance configuration.
(Ref. AMM TASK 29-00-00-864-001).
(4) Depressurize the reservoirs of the Green and Yellow hydraulic systems.
(Ref. AMM TASK 29-14-00-614-001).
(5) Put the WARNING NOTICE(S) in position to tell persons not to pressurize the Green, the Yellow and the Blue hydraulic systems:
- In the cockpit on the hydraulic section 40VU of the overhead panel
- On the ground service panels of the Green, the Yellow and the Blue hydraulic systems.
C. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | FLIGHT CONTROLS/ELAC1/NORM/SPLY | 15CE1 | B11 |
| 49VU | FLIGHT CONTROLS/THS/ACTR/MOT2 | 19CE2 | B09 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | FLIGHT CONTROLS/ELAC1/NORM/SPLY | 15CE1 | B06 |
| 49VU | FLIGHT CONTROLS/THS/ACTR/MOT2 | 19CE2 | B04 |
| ** ON A/C ALL | |||
| 105VU | FLT CTL/ELAC1/STBY SPLY | 16CE1 | A01 |
| 121VU | FLIGHT CONTROLS/THS ACTR/MOT3 | 19CE3 | Q17 |
| 121VU | FLIGHT CONTROLS/THS ACTR/MOT1 | 19CE1 | Q16 |
Subtask 27-44-51-020-054-A
A. Removal of the Filter
(1) Put a CONTAINER 3 L(3/4 USGAL) under the filter assembly (1).
(2) Remove the filter (3) from the filter assembly (1).
(3) Remove and discard the packing (2).
Subtask 27-44-51-560-051-A (1) Put a CONTAINER 3 L(3/4 USGAL) under the filter assembly (1).
(2) Remove the filter (3) from the filter assembly (1).
(3) Remove and discard the packing (2).
B. Preparation for Installation
(1) Clean the filter with the Non Aqueous Cleaner-- Petroleum Based - (Material No.08BBB1) and a Textile-Lint free Cotton - (Material No.14SBA1) .
(2) Do a visual inspection of the filter (3).
(3) Apply the Grease-Hydraulic Systems - - (Material No.03LDA1) to the new AIPC 27-44-55-01-020 PACKING (2).
(4) Install the packing (2) on the filter (3).
Subtask 27-44-51-420-054-A (1) Clean the filter with the Non Aqueous Cleaner-- Petroleum Based - (Material No.08BBB1) and a Textile-Lint free Cotton - (Material No.14SBA1) .
(2) Do a visual inspection of the filter (3).
(3) Apply the Grease-Hydraulic Systems - - (Material No.03LDA1) to the new AIPC 27-44-55-01-020 PACKING (2).
(4) Install the packing (2) on the filter (3).
C. Installation of the Filter at the Valve Block
(1) Put the filter (3) with the packing (2) in position.
(2) Install the filter (3) and the packing (2) in the filter assembly (1).
(3) TORQUE the filter (3) to between 2.3 and 2.1 m.daN (16.96 and 15.49 lbf.ft )
.
(4) Remove the CONTAINER 3 L(3/4 USGAL).
Subtask 27-44-51-865-064-A (1) Put the filter (3) with the packing (2) in position.
(2) Install the filter (3) and the packing (2) in the filter assembly (1).
(3) TORQUE the filter (3) to between 2.3 and 2.1 m.daN (16.96 and 15.49 lbf.ft )
. (4) Remove the CONTAINER 3 L(3/4 USGAL).
D. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 27-44-51-720-051-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | FLIGHT CONTROLS/ELAC1/NORM/SPLY | 15CE1 | B11 |
| 49VU | FLIGHT CONTROLS/THS/ACTR/MOT2 | 19CE2 | B09 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | FLIGHT CONTROLS/ELAC1/NORM/SPLY | 15CE1 | B06 |
| 49VU | FLIGHT CONTROLS/THS/ACTR/MOT2 | 19CE2 | B04 |
| ** ON A/C ALL | |||
| 105VU | FLT CTL/ELAC1/STBY SPLY | 16CE1 | A01 |
| 121VU | FLIGHT CONTROLS/THS ACTR/MOT3 | 19CE3 | Q17 |
| 121VU | FLIGHT CONTROLS/THS ACTR/MOT1 | 19CE1 | Q16 |
E. Test
(1) Make sure that the THS actuator has the correct quantity of oil and fill as necessary (Ref. AMM TASK 27-44-51-210-004).
(2) Do a system test of the THS control (Ref. AMM TASK 27-41-00-720-001).
5. Close-up(1) Make sure that the THS actuator has the correct quantity of oil and fill as necessary (Ref. AMM TASK 27-44-51-210-004).
(2) Do a system test of the THS control (Ref. AMM TASK 27-41-00-720-001).
WARNING:
MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS SURFACES ARE CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
(3) Do a visual check of the THS actuator and make sure that there is no leakage from: - The hydraulic connections
- The oil filler-plug connection
- The oil drain-plug connection
- The body of the THS actuator.
Subtask 27-44-51-410-064-A
A. Close Access
(1) Remove the warning notices.
(2) Make sure that the work area is clean and clear of tools and other items.
(3) Close the access door 312AR.
(4) Remove the access platform.
(1) Remove the warning notices.
(2) Make sure that the work area is clean and clear of tools and other items.
(3) Close the access door 312AR.
(4) Remove the access platform.
Replacement of the Filter