W DOC AIRBUS | AMM A320F

Installation of the Elevator Servo Control Actuator Mode Selector Valve Transducer MSVT


TASK 27-34-51-400-005-A
Installation of the Elevator Servo Control Actuator Mode Selector Valve Transducer MSVT


WARNING: MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
WARNING: MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS SURFACES ARE CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
WARNING: YOU MUST PUT ON AND ATTACH A SAFETY HARNESS BEFORE YOU START WORK:
  • ON THE THS OR IN THE REAR FUSELAGE
  • ON TOP OF THE WINGS OR PYLONS.
WITHOUT A SAFETY HARNESS, YOU CAN FALL. THIS CAN KILL YOU OR CAUSE YOU INJURY.
CAUTION: DO NOT CAUSE DAMAGE TO THE SURFACES. THE COMPONENTS ARE MADE OF CARBONFIBER REINFORCED PLASTIC.
NOTE: The installation of the servo control actuator 34CE1 mode selector valve transducer is given. The installation of the servo control actuator 34CE2, 34CE3 and 34CE4 mode selector transducer valves are the same.
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE
No specific
1
WARNING NOTICE(S)
No specific
Torque wrench: range to between 0.41 and 0.33 m.daN (36.28 and 29.20 lbf.in ) T
98D27309001000
1
NEUTRAL SETTING TOOL - ELEVATOR
98D27903500000
2
PIN-SIDE STICK LOCKING
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.03HBD9)
Synthetic Ester base Grease-General Purpose Low Temp -
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 27-34-00-710-001-A
Operational Test of the Elevator and Hydraulic Actuation
TASK 29-10-00-864-001-A
Depressurize the Green Hydraulic System
TASK 29-10-00-864-002-A
Depressurize the Yellow Hydraulic System
TASK 29-10-00-864-003-A
Depressurize the Blue Hydraulic System
TASK 29-14-00-614-001-A
Depressurization of the Hydraulic Reservoirs
TASK 55-13-11-000-001-A
Remove/Open of the Trimmable Horizontal Stabilizer (THS) Trailing-Edge Access-Panels
TASK 55-13-11-400-001-A
Install/Close of the Trimmable Horizontal Stabilizer (THS) Trailing-Edge Access-Panels
3. Job Set-up
Subtask 27-34-51-860-067-A
A. Aircraft Maintenance Configuration
   (1) Make sure that the elevators and the horizontal stabilizer are set to the neutral position.
   (2) Make sure that the 98D27903500000 PIN-SIDE STICK LOCKING are in position in the CAPT and F/O side stick controllers.
   (3) Make sure that the 98D27309001000 NEUTRAL SETTING TOOL - ELEVATOR is installed on the elevator.
   (4) Make sure that the hydraulic systems are depressurized (Ref. AMM TASK 29-10-00-864-001), (Ref. AMM TASK 29-10-00-864-002), (Ref. AMM TASK 29-10-00-864-003).
   (5) Make sure that the hydraulic reservoirs are depressurized (Ref. AMM TASK 29-14-00-614-001).
   (6) Make sure that the WARNING NOTICE(S) are in position in the flight compartment to tell persons not to operate the flight controls.
   (7) Make sure that the WARNING NOTICE(S) are in position to tell persons not to operate the hydraulic systems.
   (8) Make sure that the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE is in position at zone 334 and/or zone 344.
   (9) Make sure that access panels 334DB and/or 344DB are open (Ref. AMM TASK 55-13-11-000-001).
Subtask 27-34-51-865-079-A
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/ELAC1/NORM/SPLY15CE1B11
49VUFLIGHT CONTROLS/FCDC1/SPLY20CE1B10
49VUFLIGHT CONTROLS/THS/ACTR/MOT219CE2B09
49VUFLIGHT CONTROLS/SEC1/NORM/SPLY21CE1B08
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/ELAC1/NORM/SPLY15CE1B06
49VUFLIGHT CONTROLS/FCDC1/SPLY20CE1B05
49VUFLIGHT CONTROLS/THS/ACTR/MOT219CE2B04
49VUFLIGHT CONTROLS/SEC1/NORM/SPLY21CE1B03
** ON A/C ALL
105VUFLIGHT CONTROLS/ELAC2/STBY SPLY16CE2A02
105VUFLT CTL/ELAC1/STBY SPLY16CE1A01
105VUFLT CTL/SEC1/STBY SPLY22CEB01
121VUFLIGHT CONTROLS/FCDC2/SPLY20CE2Q20
121VUFLIGHT CONTROLS/SEC2/SPLY21CE2Q18
121VUFLIGHT CONTROLS/THS ACTR/MOT319CE3Q17
121VUFLIGHT CONTROLS/THS ACTR/MOT119CE1Q16
121VUFLIGHT CONTROLS/ELAC2/NORM/SPLY15CE2R20
Subtask 27-34-51-140-054-A
C. Cleaning
   (1) Clean the component interfaces and the adjacent area.
   (2) Make sure that the parts retained from the removed component are clean and in the correct condition.
4. Procedure
Subtask 27-34-51-420-057-A
A. Install the servo control actuator MSVT
   (1) Apply Synthetic Ester base Grease-General Purpose Low Temp - (Material No.03HBD9) to the bolts (4).
   (2) Install the O rings (6) and (7) in the MSVT (3).
   (3) Put the MSVT (3) in position on the servo control actuator and support it.
   (4) Install the washers (5) and the bolts (4) into the MSVT (3).
   (5) TORQUE the bolts (4) to between 0.41 and 0.33 m.daN (36.28 and 29.20 lbf.in ) T
   (6) Remove the blanking caps.
   (7) Connect the electrical connectors.
Subtask 27-34-51-081-053-A
B. Remove Locking Devices
   (1) Remove the 98D27903500000 PIN-SIDE STICK LOCKING from the CAPT and F/O side stick controllers.
   (2) Remove the 98D27309001000 NEUTRAL SETTING TOOL - ELEVATOR from the elevator:
     (a) Release the wing nut (6).
     (b) Remove the T-handle screw (1) and the washer (2).
     (c) Remove the set of bars (3) and plates (7) and (8).
     (d) Install the T-handle screw (1) and the washer (2) in the stowage on the center plate(7).
     (e) Tighten the wing nut (6).
Subtask 27-34-51-865-059-A
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/ELAC1/NORM/SPLY15CE1B11
49VUFLIGHT CONTROLS/FCDC1/SPLY20CE1B10
49VUFLIGHT CONTROLS/THS/ACTR/MOT219CE2B09
49VUFLIGHT CONTROLS/SEC1/NORM/SPLY21CE1B08
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/ELAC1/NORM/SPLY15CE1B06
49VUFLIGHT CONTROLS/FCDC1/SPLY20CE1B05
49VUFLIGHT CONTROLS/THS/ACTR/MOT219CE2B04
49VUFLIGHT CONTROLS/SEC1/NORM/SPLY21CE1B03
** ON A/C ALL
105VUFLIGHT CONTROLS/ELAC2/STBY SPLY16CE2A02
105VUFLT CTL/ELAC1/STBY SPLY16CE1A01
105VUFLT CTL/SEC1/STBY SPLY22CEB01
121VUFLIGHT CONTROLS/FCDC2/SPLY20CE2Q20
121VUFLIGHT CONTROLS/SEC2/SPLY21CE2Q18
121VUFLIGHT CONTROLS/THS ACTR/MOT319CE3Q17
121VUFLIGHT CONTROLS/THS ACTR/MOT119CE1Q16
121VUFLIGHT CONTROLS/ELAC2/NORM/SPLY15CE2R20
Subtask 27-34-51-710-053-A
D. Operational Test
   (1) Do an operational test of the servo controls. (Ref. AMM TASK 27-34-00-710-001)
5. Close-up
Subtask 27-34-51-410-055-A
A. Visual Inspection
   (1) Make sure that the work area is clean and clear of tools and other items.
Subtask 27-34-51-410-056-A
B. Close Access
   (1) Close trailing-edge access panels 334DB and/or 344DB (Ref. AMM TASK 55-13-11-400-001)
Subtask 27-34-51-942-055-A
C. Removal of the Ground Equipment
   (1) Remove the WARNING NOTICE(S).
   (2) Remove the access platform(s).
[Rev.10 from 2021] 2026.03.31 23:50:33 UTC