W DOC AIRBUS | AMM A320F

Removal of the Filter from the Rudder Servo Control


TASK 27-24-51-000-002-A
Removal of the Filter from the Rudder Servo Control


WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
ZONE: 325
FIN: 1025GM
FIN: 2025GM
FIN: 3025GM
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 10M (33 FT) - ADJUSTABLE
No specific
AR
CONTAINER 5 L (1.32 USGAL)
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
325
VERTICAL STABILIZER TRAILING EDGE
325CL, 325CR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 29-00-00-864-001-A
Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action
TASK 29-14-00-614-001-A
Depressurization of the Hydraulic Reservoirs
TASK 55-33-13-010-002-A
Opening/Removal of the Trailing Edge Access-Panels of the Vertical Stabilizer
3. Job Set-up
Subtask 27-24-51-860-052-A
A. Aircraft Maintenance Configuration
   (1) Make sure that the hydraulic systems are depressurized and put them in the maintenance configuration
(Ref. AMM TASK 29-00-00-864-001)
   (2) Depressurize the reservoirs of the Green, Yellow and Blue hydraulic systems.
(Ref. AMM TASK 29-14-00-614-001).
   (3) Put the WARNING NOTICE(S) in position to tell persons not to pressurize the hydraulic systems.
   (4) Put the WARNING NOTICE(S) in the flight compartment to tell persons not to operate the flight controls.
Subtask 27-24-51-010-051-B
B. Get Access
   (1) Put the ACCESS PLATFORM 10M (33 FT) - ADJUSTABLE in position.
   (2) Open the access panels 325CL 325CR at the trailing edge of the vertical stabilizer, (Ref. AMM TASK 55-33-13-010-002).
   (3) Put the CONTAINER 5 L (1.32 USGAL) below the servo control.
4. Procedure
Subtask 27-24-51-020-053-A
A. Removal of the Filter
NOTE: The removal of the filter (16) from the upper servo control 2025GM (5) only is described. The removal of the filter (16) from the center 3025GM and the lower 1025GM servo controls (5) is similar.
   (1) Cut and remove the lockwire from the connection of the filter (16) to the valve block (14) of the servo control (5).
   (2) Remove the sealing compound from the connection of the filter (16) to the valve block (14).
   (3) Remove the filter (16) from the valve block (14).
   (4) Remove and discard the packing (15) and the filter (16).