W DOC AIRBUS | AMM A320F

Installation of the Cable Tension Regulator


TASK 27-21-45-400-003-A
Installation of the Cable Tension Regulator


ZONE: 125
FIN: 103CM
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Consumable Materials
REFERENCE
DESIGNATION
(Material No.05BAE1)
Threadlocking Adhesive-- Medium strength -
(Material No.05BAF1)
Threadlocking Adhesive-- Medium strength Low viscosity -
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
125
LATERAL AVIONIC COMPARTMENT
 C. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
15
PIN
AIPC 27-21-01-12-143
2
COTTER PIN
AIPC 27-21-01-12-143
17
COTTER PIN
AIPC 27-21-01-12-154
15
COTTER PIN
AIPC 27-21-81-12-160
2
COTTER PIN
AIPC 27-21-81-12-160
17
COTTER PIN
AIPC 27-21-81-12-270
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 27-21-45-000-003-A
Removal of the Cable Tension Regulator
TASK 27-21-45-400-001-A
Installation of the Cable Tension Regulator Assy
3. Job Set-up
Subtask 27-21-45-860-052-A
A. Make sure that the cable tension regulator is removed (Ref. AMM TASK 27-21-45-000-003).
4. Procedure
Subtask 27-21-45-910-050-A
A. Preparation for Installation
   (1) Clean the component interfaces and the adjacent area.
   (2) Do an inspection of the component interfaces and the adjacent area.
Subtask 27-21-45-420-053-A
B. Installation of the Cable Tension Regulator
   (1) Make sure that the spacer (4), the link (5) and the spacer (20) are still installed on the side fitting (9).
   (2) Install the side fittings (9) and (23) on the cable tension regulator (11).
   (3) Install the bolt (7), the washers (6) and (3), the nut (1) and tighten.
   (4) Install a new AIPC 27-21-01-12-143 COTTER PIN (2) or AIPC 27-21-81-12-160 COTTER PIN (2).
   (5) Install the six bolts (12), the six nuts (10) and tighten.
   (6) Install the pin (8), the sleeve (13) and the belcrank assy (19).
   (7) Lock the nut (14).
   (8) Install a new
AIPC 27-21-01-12-143 PIN (15) or AIPC 27-21-81-12-160 COTTER PIN (15).
   (9) Install the washer (16), the nut (18) and tighten.
   (10) Install a new
AIPC 27-21-01-12-154 COTTER PIN (17) or AIPC 27-21-81-12-270 COTTER PIN (17).
   (11) Install the plate (22).
   (12) Apply Threadlocking Adhesive-- Medium strength Low viscosity - (Material No.
05BAF1) or Threadlocking Adhesive-- Medium strength - (Material No.05BAE1) on the six screws (21).
   (13) Install the six screws (21) and tighten them.
5. Close-up
Subtask 27-21-45-420-054-A
A. Install the cable tension regulator assy (Ref. AMM TASK 27-21-45-400-001).
[Rev.10 from 2021] 2026.03.31 23:48:31 UTC