Removal of the Linear Variable Differential Transducer (LVDT) of the Aileron Servo-Control
TASK 27-14-51-000-005-A
Removal of the Linear Variable Differential Transducer (LVDT) of the Aileron Servo-Control
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 27-14-51-941-062-A
[Rev.10 from 2021]
2026.03.31 23:47:40 UTC
Removal of the Linear Variable Differential Transducer (LVDT) of the Aileron Servo-Control
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
CAUTION:
BE CAREFUL WHEN YOU DO MAINTENANCE TASKS ON THE WING TRAILING EDGE:
1. Reason for the Job- DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE RACEWAYS.
- DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE INSTALLATIONS.
- MAKE SURE THAT THE ELECTRICAL CABLES ARE INSTALLED CORRECTLY. INCORRECT INSTALLATION CAN CAUSE DAMAGE.
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 4M (13 FT) |
| No specific | AR | CONTAINER 1 L (1/4 USGAL) |
| No specific | AR | COVER - PROTECTION |
| No specific | AR | SAFETY BARRIER(S) |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 575AT, 675AT |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 29-10-00-864-001-A | Depressurize the Green Hydraulic System |
| TASK 29-10-00-864-003-A | Depressurize the Blue Hydraulic System |
| TASK 29-14-00-614-001-A | Depressurization of the Hydraulic Reservoirs |
| TASK 29-23-00-860-001-A | Disconnection of the Isolation Coupling of the Power Transfer Unit (PTU) |
Subtask 27-14-51-941-062-A
A. Safety Precautions
(1) Put the SAFETY BARRIER(S) in position.
(2) Put the WARNING NOTICE(S) in the cockpit to tell persons not to pressurize the Green or the Blue hydraulic systems.
Subtask 27-14-51-860-058-A (1) Put the SAFETY BARRIER(S) in position.
(2) Put the WARNING NOTICE(S) in the cockpit to tell persons not to pressurize the Green or the Blue hydraulic systems.
B. Aircraft Maintenance Configuration
(2) Make sure that the Green and the Blue hydraulic systems are depressurized (Ref. AMM TASK 29-10-00-864-001) (Ref. AMM TASK 29-10-00-864-003).
(3) Depressurize the Green and the Blue hydraulic system reservoirs (Ref. AMM TASK 29-14-00-614-001).
Subtask 27-14-51-865-062-A WARNING:
OBEY THE HYDRAULIC SAFETY PROCEDURES.
(1) Disconnect the Isolation Coupling of the Power Transfer Unit (PTU) (Ref. AMM TASK 29-23-00-860-001). (2) Make sure that the Green and the Blue hydraulic systems are depressurized (Ref. AMM TASK 29-10-00-864-001) (Ref. AMM TASK 29-10-00-864-003).
(3) Depressurize the Green and the Blue hydraulic system reservoirs (Ref. AMM TASK 29-14-00-614-001).
C. Open, safety and tag this(these) circuit breaker(s):
Subtask 27-14-51-010-054-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | FLIGHT CONTROLS/ELAC1/NORM/SPLY | 15CE1 | B11 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | FLIGHT CONTROLS/ELAC1/NORM/SPLY | 15CE1 | B06 |
| ** ON A/C ALL | |||
| 105VU | FLIGHT CONTROLS/ELAC2/STBY SPLY | 16CE2 | A02 |
| 105VU | FLT CTL/ELAC1/STBY SPLY | 16CE1 | A01 |
| 121VU | FLIGHT CONTROLS/ELAC2/NORM/SPLY | 15CE2 | R20 |
D. Get Access
(1) Put the ACCESS PLATFORM 4M (13 FT) in position under the applicable zone 575(675).
(2) Remove the applicable access panel:
4. Procedure(1) Put the ACCESS PLATFORM 4M (13 FT) in position under the applicable zone 575(675).
(2) Remove the applicable access panel:
CAUTION:
BE CAREFUL WHEN YOU DO MAINTENANCE TASKS ON THE WING TRAILING EDGE:
Subtask 27-14-51-020-054-A - DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE RACEWAYS.
- DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE INSTALLATIONS.
- MAKE SURE THAT THE ELECTRICAL CABLES ARE INSTALLED CORRECTLY. INCORRECT INSTALLATION CAN CAUSE DAMAGE.
A. Removal of the LVDT of the Aileron Servo-Control
(2) Remove and discard the lockwire from the bolts (1).
(3) Remove the bolts (1), the washers (2), the lockwasher (9) and the bonding leads (8).
(4) Carefully disengage the LVDT (3) from the electrical connector (5) and remove the LVDT (3).
(6) Remove and discard the packing (6) from the socket (7).
(7) Put the COVER - PROTECTION on the aileron servo-control interface.
WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(1) Put a CONTAINER 1 L (1/4 USGAL) below the applicable LVDT (3). (2) Remove and discard the lockwire from the bolts (1).
(3) Remove the bolts (1), the washers (2), the lockwasher (9) and the bonding leads (8).
(4) Carefully disengage the LVDT (3) from the electrical connector (5) and remove the LVDT (3).
NOTE: A spring in the aileron servo-control will push the LVDT (3) away from the aileron servo-control.
(5) Remove and discard the packing (4) from the LVDT (3). (6) Remove and discard the packing (6) from the socket (7).
(7) Put the COVER - PROTECTION on the aileron servo-control interface.
Aileron Servo-Control LVDT