Installation of the Cargo Fire-Extinguisher Bottle
TASK 26-23-42-400-001-A
Installation of the Cargo Fire-Extinguisher Bottle
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Expendable Parts
E. Referenced Information
3. Job Set-up
Subtask 26-23-42-860-050-A ** ON A/C NOT FOR ALL
Subtask 26-23-42-420-050-A ** ON A/C NOT FOR ALL
Subtask 26-23-42-410-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 23:46:44 UTC
Installation of the Cargo Fire-Extinguisher Bottle
WARNING:
BE CAREFUL WHEN YOU REMOVE OR INSTALL THIS EQUIPMENT. THIS EQUIPMENT IS HEAVY (MORE THAN 12 KG (26.5 lb)) AND CAN CAUSE INJURY AND/OR DAMAGE.
WARNING:
IF YOU REMOVE THE FIRE EXTINGUISHER BOTTLES IN A CLOSED HANGAR, MAKE SURE THAT THERE IS A FLOW OF NEW AIR IN THE HANGAR.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
CAUTION:
BEFORE YOU INSTALL/REMOVE THE GSE-TOOL, READ THE INSTRUCTIONS IN THE APPLICABLE GSE INSTRUCTION MANUAL. WHILE YOU OPERATE THIS TOOL, CAREFULLY OBEY THEM. IF YOU DO NOT OBEY THE INSTRUCTIONS, DAMAGE TO EQUIPMENT CAN OCCUR.
1. Reason for the JobNOTE: Two persons are necessary to do this task.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.03GEE1) | Synthetic Oil base Grease-Fuel and Oxidized Environment Fluorinated - |
| (Material No.06AAC1) | Polysulfide Sealant-General Purpose Interfay - |
| (Material No.14QEB1) | Wire-Locking Dia: 0.6 mm CRES Nickel Alloy - |
| (Material No.14QFB1) | Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - |
| (Material No.14QGC1) | Wire-Locking Dia: 1 mm (0.041 inch) CRES - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 150 | AFT CARGO COMPARTMENT FWD PRESS BULKHEAD TO AFT BULKHEAD OF AFT CARGO COMPARTMENT |
| 160 | BULK CARGO COMPARTMENT AFT BULKHEAD OF AFT CARGO COMPARTMENT TO AFT BULKHEAD OF BULK CARGO COMPARTMENT |
| 170 | AFT CAB U/FLOOR COMPT AFT BHD OF BULK |
| 826 | |
| 161DW | |
| 162AW |
| FIG.ITEM | DESIGNATION | IPC-CSN |
|---|---|---|
| 12 | LOCK WASHER | AIPC 26-23-04-02-080 |
| 11 | LOCK WASHER | AIPC 26-23-04-07-090 |
| 12 | LOCK WASHER | AIPC 26-23-04-07-090 |
| 11 | WASHER | AIPC 26-23-04-07-175 |
| 11 | LOCK WASHER | AIPC 26-23-84-07-245 |
| 12 | LOCK WASHER | AIPC 26-23-84-07-245 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 20-28-00-912-802-A | Electrical Bonding - General Maintenance Procedure |
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 25-55-12-000-001-A | Removal of the Aft Cargo-Compartment Partition at FR65 |
| TASK 25-55-12-000-003-A | Removal of the Sidewall Panels in the Aft Cargo Compartment - FR59/FR65 |
| TASK 25-55-12-400-001-A | Installation of the Aft Cargo-Compartment Partition at FR65 |
| TASK 25-55-12-400-003-A | Installation of the Sidewall Panels in the Aft Cargo Compartment - FR59/FR65 |
| TASK 26-16-00-710-001-A | Operational Check of Cargo Compartment Smoke Detection by PTT |
| TASK 26-23-00-200-005-A | Restoration of the Fire Extinguishing System (FES) after Activation |
| TASK 26-23-41-280-001-C | Remove Cargo Compartment Fire Extinguisher Bottle for in shop Weight Check. |
| TASK 26-23-42-400-004-A | Installation of the Cartridge of the Cargo Fire-Extinguisher Bottle |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 52-30-00-860-002-A | Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 26-23-00-00 | CARGO COMPARTMENT FIRE EXTINGUISHING - DESCRIPTION AND OPERATION |
Subtask 26-23-42-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) If the installation of the cargo fire-extinguisher bottle is done after a discharge of the fire extinguishing agent:
(Ref. AMM TASK 24-42-00-861-001).
(3) Before the installation of the cargo fire-extinguisher bottle, do the weight check of the bottle (Ref. AMM TASK 26-23-41-280-001).
Subtask 26-23-42-010-053-A ** ON A/C NOT FOR ALL (1) If the installation of the cargo fire-extinguisher bottle is done after a discharge of the fire extinguishing agent:
- Do the restoration of the fire extinguishing system after activation (Ref. AMM TASK 26-23-00-200-005).
(Ref. AMM TASK 24-42-00-861-001).
(3) Before the installation of the cargo fire-extinguisher bottle, do the weight check of the bottle (Ref. AMM TASK 26-23-41-280-001).
NOTE: If the cargo fire-extinguisher bottle was weighed in a short time before this installation it is not necessary to weigh it again.
B. Get Access
(1) For the location of this component, refer to Para. Component Location (Ref. AMM D/O 26-23-00-00).
(2) Make sure that the aft cargo-compartment door 826 is open (Ref. AMM TASK 52-30-00-860-001).
(3) Make sure that the CARGO COMPT LIGHT switch 8LU is in the ON position.
(4) Make sure that the sidewall panel 162AW is removed (Ref. AMM TASK 25-55-12-000-003).
(5) Make sure that the cartridge is installed on the fire extinguisher bottle (Ref. AMM TASK 26-23-42-400-004).
(6) Make sure that the protective cap is installed on the cartridge.
(7) Clean the component interfaces and the adjacent area.
(8) Do an inspection of the component interfaces and the adjacent area.
Subtask 26-23-42-010-053-B ** ON A/C NOT FOR ALL (1) For the location of this component, refer to Para. Component Location (Ref. AMM D/O 26-23-00-00).
(2) Make sure that the aft cargo-compartment door 826 is open (Ref. AMM TASK 52-30-00-860-001).
(3) Make sure that the CARGO COMPT LIGHT switch 8LU is in the ON position.
(4) Make sure that the sidewall panel 162AW is removed (Ref. AMM TASK 25-55-12-000-003).
(5) Make sure that the cartridge is installed on the fire extinguisher bottle (Ref. AMM TASK 26-23-42-400-004).
(6) Make sure that the protective cap is installed on the cartridge.
(7) Clean the component interfaces and the adjacent area.
(8) Do an inspection of the component interfaces and the adjacent area.
B. Get Access
(1) For the location of this component, refer to Para. Component Location (Ref. AMM D/O 26-23-00-00).
(2) Make sure that the aft cargo-compartment door 826 is open (Ref. AMM TASK 52-30-00-860-001).
(3) Make sure that the CARGO COMPT LIGHT switch 8LU is in the ON position.
(4) Make sure that the partition panel 161DW is removed (Ref. AMM TASK 25-55-12-000-001).
(5) Make sure that the cartridge is installed on the fire extinguisher bottle (Ref. AMM TASK 26-23-42-400-004).
(6) Make sure that the protective cap is installed on the cartridge.
(7) Clean the component interfaces and the adjacent area.
(8) Do an inspection of the component interfaces and the adjacent area.
Subtask 26-23-42-865-051-A ** ON A/C NOT FOR ALL (1) For the location of this component, refer to Para. Component Location (Ref. AMM D/O 26-23-00-00).
(2) Make sure that the aft cargo-compartment door 826 is open (Ref. AMM TASK 52-30-00-860-001).
(3) Make sure that the CARGO COMPT LIGHT switch 8LU is in the ON position.
(4) Make sure that the partition panel 161DW is removed (Ref. AMM TASK 25-55-12-000-001).
(5) Make sure that the cartridge is installed on the fire extinguisher bottle (Ref. AMM TASK 26-23-42-400-004).
(6) Make sure that the protective cap is installed on the cartridge.
(7) Clean the component interfaces and the adjacent area.
(8) Do an inspection of the component interfaces and the adjacent area.
C. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/CARGO FIRE/EXTIG/BTL2 | 8WX | C04 |
| 49VU | AIR COND/CARGO FIRE/EXTIG/BTL1 | 1WX | C03 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/CARGO/FIRE/EXTIG | 1WX | T19 |
Subtask 26-23-42-420-050-A ** ON A/C NOT FOR ALL
A. Installation of the Cargo Fire-Extinguisher Bottle
(1) Apply Polysulfide Sealant-General Purpose Interfay - (Material No.06AAC1) to the upper brackets of the fire extinguisher bottle (1).
(2) Install the fire extinguisher bottle (1) as follows:
(b) Install the bolts (6) and the nuts (17).
(c) Tighten the nuts (17).
(3) Remove the blanking plugs from:
(5) TORQUE the coupling nuts (18) to between 6.8 and 5.4 m.daN (50.15 and 39.82 lbf.ft )
.
14QFB1 Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - .
(8) Connect the flexible hose (14) to the safety relief valve (7).
(9) TORQUE the nut (15) to between 1.7 and 1.5 m.daN (12.54 and 11.06 lbf.ft )
.
(10) Connect the flexible hoses (4) to the discharge heads (19).
(11) TORQUE the nuts (5) to between 4.3 and 3.9 m.daN (31.71 and 28.76 lbf.ft )
.
(12) Install the bonding straps (24) and the nuts (23) on the ground lug bolts (25) (Ref. AMM TASK 20-28-00-912-802).
(13) TORQUE the nuts (23) to between 0.35 and 0.3 m.daN (30.97 and 26.55 lbf.in )
.
(14) Make sure that you are grounded with the ELECTRICALLY GROUNDED WRIST STRAP.
14QFB1 Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - .
(a) Remove the CAP-BLANKING from each electrical connector and receptacle.
(b) Remove the protective caps (20) from the cartridges (22).
(c) Connect the electrical connectors (21) to the cartridges (22).
(d) Connect the electrical connector (2) to the pressure switch (3).
14QEB1 Wire-Locking Dia: 0.6 mm CRES Nickel Alloy - .
(18) Put the eye-end of the tie-rod (10) in position between the lugs of the fire extinguisher bottle (1).
(19) If necessary, adjust the tie-rod as follows:
(a) Loosen the lock nut (11) and remove the eye-end of the tie-rod (10) from the rod-end (13).
(b) Remove and discard the lock washer (12).
(c) Install the new AIPC 26-23-04-02-080 LOCK WASHER (12) and the eye-end of the tie-rod (10) on the rod-end (13).
(d) Adjust the tie-rod (10) until the bolt (9) goes through the eye-end of the tie-rod (10) and the lugs of the fire extinguisher bottle (1).
(e) Tighten the lock nut (11).
(f) Safety the lock nut (11) with the lock washer (12).
(20) Install the bolt (9) and the nut (8).
Subtask 26-23-42-420-050-C ** ON A/C NOT FOR ALL (1) Apply Polysulfide Sealant-General Purpose Interfay - (Material No.06AAC1) to the upper brackets of the fire extinguisher bottle (1).
(2) Install the fire extinguisher bottle (1) as follows:
WARNING:
BE VERY CAREFUL WHEN YOU MOVE A FULL FIRE EXTINGUISHER BOTTLE. A SUDDEN OR HEAVY SHOCK TO A FULL BOTTLE CAN CAUSE UNWANTED DISCHARGE AND INJURY TO PERSONS.
CAUTION:
IF YOU MUST MOVE THE TOOL IN THE AIRCRAFT, BE CAREFUL NOT TO DAMAGE THE PEEL SHIMS OF THE SUPPORTS OF THE ADIRU MOUNT.
(a) Hold the fire extinguisher bottle (1) in its correct installation position on the structure (16). (b) Install the bolts (6) and the nuts (17).
(c) Tighten the nuts (17).
(3) Remove the blanking plugs from:
- The disconnected line ends
- The safety relief valve (7)
- The discharge heads (19).
(5) TORQUE the coupling nuts (18) to between 6.8 and 5.4 m.daN (50.15 and 39.82 lbf.ft )
. WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(6) Safety the coupling nuts (18) with CAUTION:
APPLY A SMALL QUANTITY OF THE CORRECT GREASE TO THE MALE THREADS OF THE CONNECTIONS. THIS WILL PREVENT DAMAGE TO THE THREADS.
MAKE SURE THAT GREASE DOES NOT GO INTO THE PIPES. GREASE IN THE PIPES CAN CAUSE A MALFUNCTION OF THE SYSTEM.
(7) Apply a small quantity of Synthetic Oil base Grease-Fuel and Oxidized Environment Fluorinated - (Material No.03GEE1) to the male threads of the safety relief valve (7) and the discharge heads (19). (8) Connect the flexible hose (14) to the safety relief valve (7).
(9) TORQUE the nut (15) to between 1.7 and 1.5 m.daN (12.54 and 11.06 lbf.ft )
. (10) Connect the flexible hoses (4) to the discharge heads (19).
(11) TORQUE the nuts (5) to between 4.3 and 3.9 m.daN (31.71 and 28.76 lbf.ft )
. (12) Install the bonding straps (24) and the nuts (23) on the ground lug bolts (25) (Ref. AMM TASK 20-28-00-912-802).
(13) TORQUE the nuts (23) to between 0.35 and 0.3 m.daN (30.97 and 26.55 lbf.in )
. (14) Make sure that you are grounded with the ELECTRICALLY GROUNDED WRIST STRAP.
WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(15) Safety the cartridges (22) with WARNING:
BEFORE YOU TOUCH THE POWER DEVICE CARTRIDGE, MAKE SURE THAT YOU ARE GROUNDED AND THAT YOU INSTALL A SHUNT DEVICE ON IT. USE A CAP OR PLUG AS SHUNT DEVICE (THE CAP OR PLUG WILL SHUNT THE PINS TOGETHER ON THE CARTRIDGE). DO NOT USE A FOIL SHUNT.
IF YOU TOUCH A POWER DEVICE CARTRIDGE THAT DOES NOT HAVE A SHUNT DEVICE INSTALLED, AN EXPLOSION CAN OCCUR AND CAUSE INJURIES TO YOU.
CAUTION:
MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
CAUTION:
REFER TO THE MATCH MARKS MADE DURING THE REMOVAL WHEN YOU CONNECT THE ELECTRICAL WIRES.
INCORRECT CONNECTION OF THE WIRES WILL CAUSE DAMAGE TO EQUIPMENT.
CAUTION:
MAKE SURE THAT THE BONDING STRAP(S) IS(ARE) CONNECTED BEFORE YOU CONNECT THE ELECTRICAL WIRE(S).
(16) Connect the electrical connectors (2) and (21) as follows: (a) Remove the CAP-BLANKING from each electrical connector and receptacle.
(b) Remove the protective caps (20) from the cartridges (22).
(c) Connect the electrical connectors (21) to the cartridges (22).
(d) Connect the electrical connector (2) to the pressure switch (3).
WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(17) Safety the electrical connectors (21) with (18) Put the eye-end of the tie-rod (10) in position between the lugs of the fire extinguisher bottle (1).
(19) If necessary, adjust the tie-rod as follows:
(a) Loosen the lock nut (11) and remove the eye-end of the tie-rod (10) from the rod-end (13).
(b) Remove and discard the lock washer (12).
(c) Install the new AIPC 26-23-04-02-080 LOCK WASHER (12) and the eye-end of the tie-rod (10) on the rod-end (13).
(d) Adjust the tie-rod (10) until the bolt (9) goes through the eye-end of the tie-rod (10) and the lugs of the fire extinguisher bottle (1).
(e) Tighten the lock nut (11).
(f) Safety the lock nut (11) with the lock washer (12).
(20) Install the bolt (9) and the nut (8).
A. Installation of the Cargo Fire-Extinguisher Bottle
(1) Apply Polysulfide Sealant-General Purpose Interfay - (Material No.06AAC1) to the upper brackets of the fire extinguisher bottle (1).
(2) Install the fire extinguisher bottle (1) as follows:
(b) Install the bolts (6) and the nuts (17).
(3) Remove the blanking plugs from:
(5) If the discharge heads (19) are not aligned, do the steps that follow:
(b) Loosen the coupling nuts (18).
(c) Align the discharge heads (19) with the flexible hoses (4).
(d) TORQUE the coupling nuts (18) to between 6.8 and 5.4 m.daN (50.15 and 39.82 lbf.ft )
.
(e) Safety the coupling nuts (18) with14QFB1 Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - .
(7) Connect the flexible hose (14) to the safety relief valve (7).
(8) TORQUE the nut (15) to between 1.7 and 1.5 m.daN (12.54 and 11.06 lbf.ft )
.
(9) Connect the flexible hoses (4) to the discharge heads (19).
(10) TORQUE the nuts (5) to between 4.3 and 3.9 m.daN (31.71 and 28.76 lbf.ft )
.
(11) Install the bonding straps (24) and the nuts (23) on the ground lug bolts (25) (Ref. AMM TASK 20-28-00-912-802).
(12) TORQUE the nuts (23) to between 0.35 and 0.3 m.daN (30.97 and 26.55 lbf.in )
.
(13) Make sure that you are grounded with the ELECTRICALLY GROUNDED WRIST STRAP.
14QFB1 Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - .
(a) Remove the CAP-BLANKING from each electrical connector and receptacle.
(b) Remove the protective caps (20) from the cartridges (22).
(c) Connect the electrical connectors (21) to the cartridges (22).
(d) Connect the electrical connector (2) to the pressure switch (3).
14QEB1 Wire-Locking Dia: 0.6 mm CRES Nickel Alloy - .
(17) Put the eye-end of the tie-rod (10) in position between the lugs of the fire extinguisher bottle (1).
(18) If necessary, adjust the tie-rod as follows:
(a) Loosen the lock nut (11) and remove the eye-end of the tie-rod (10) from the rod-end (13).
(b) Remove and discard the lock washer (12).
(c) Install the new AIPC 26-23-04-07-090 LOCK WASHER (12) or AIPC 26-23-84-07-245 LOCK WASHER (12) and the eye-end of the tie-rod (10) on the rod-end (13).
(d) Adjust the tie-rod (10) until the bolt (9) goes through the eye-end of the tie-rod (10) and the lugs that are on the fire extinguisher bottle (1).
(e) Tighten the lock nut (11).
(f) Safety the lock nut (11) with the lock washer (12).
(19) Install the bolt (9) and the nut (8).
Subtask 26-23-42-420-050-H ** ON A/C NOT FOR ALL (1) Apply Polysulfide Sealant-General Purpose Interfay - (Material No.06AAC1) to the upper brackets of the fire extinguisher bottle (1).
(2) Install the fire extinguisher bottle (1) as follows:
WARNING:
BE VERY CAREFUL WHEN YOU MOVE A FULL FIRE EXTINGUISHER BOTTLE. A SUDDEN OR HEAVY SHOCK TO A FULL BOTTLE CAN CAUSE UNWANTED DISCHARGE AND INJURY TO PERSONS.
(a) Hold the fire extinguisher bottle (1) in its correct installation position on the structure (16). (b) Install the bolts (6) and the nuts (17).
(3) Remove the blanking plugs from:
- The disconnected line ends
- The safety relief valve (7)
- The discharge heads (19).
(5) If the discharge heads (19) are not aligned, do the steps that follow:
WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(a) Remove and discard the lockwire. (b) Loosen the coupling nuts (18).
(c) Align the discharge heads (19) with the flexible hoses (4).
(d) TORQUE the coupling nuts (18) to between 6.8 and 5.4 m.daN (50.15 and 39.82 lbf.ft )
.(e) Safety the coupling nuts (18) with
CAUTION:
APPLY A SMALL QUANTITY OF THE CORRECT GREASE TO THE MALE THREADS OF THE CONNECTIONS. THIS WILL PREVENT DAMAGE TO THE THREADS.
MAKE SURE THAT GREASE DOES NOT GO INTO THE PIPES. GREASE IN THE PIPES CAN CAUSE A MALFUNCTION OF THE SYSTEM.
(6) Apply a small quantity of Synthetic Oil base Grease-Fuel and Oxidized Environment Fluorinated - (Material No.03GEE1) to the male threads of the safety relief valve (7) and the discharge heads (19). (7) Connect the flexible hose (14) to the safety relief valve (7).
(8) TORQUE the nut (15) to between 1.7 and 1.5 m.daN (12.54 and 11.06 lbf.ft )
. (9) Connect the flexible hoses (4) to the discharge heads (19).
(10) TORQUE the nuts (5) to between 4.3 and 3.9 m.daN (31.71 and 28.76 lbf.ft )
. (11) Install the bonding straps (24) and the nuts (23) on the ground lug bolts (25) (Ref. AMM TASK 20-28-00-912-802).
(12) TORQUE the nuts (23) to between 0.35 and 0.3 m.daN (30.97 and 26.55 lbf.in )
. (13) Make sure that you are grounded with the ELECTRICALLY GROUNDED WRIST STRAP.
WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(14) Safety the cartridges (22) with WARNING:
BEFORE YOU TOUCH THE POWER DEVICE CARTRIDGE, MAKE SURE THAT YOU ARE GROUNDED AND THAT YOU INSTALL A SHUNT DEVICE ON IT. USE A CAP OR PLUG AS SHUNT DEVICE (THE CAP OR PLUG WILL SHUNT THE PINS TOGETHER ON THE CARTRIDGE). DO NOT USE A FOIL SHUNT.
IF YOU TOUCH A POWER DEVICE CARTRIDGE THAT DOES NOT HAVE A SHUNT DEVICE INSTALLED, AN EXPLOSION CAN OCCUR AND CAUSE INJURIES TO YOU.
CAUTION:
MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
CAUTION:
REFER TO THE MATCH MARKS MADE DURING THE REMOVAL WHEN YOU CONNECT THE ELECTRICAL WIRES.
INCORRECT CONNECTION OF THE WIRES WILL CAUSE DAMAGE TO EQUIPMENT.
CAUTION:
MAKE SURE THAT THE BONDING STRAP(S) IS(ARE) CONNECTED BEFORE YOU CONNECT THE ELECTRICAL WIRE(S).
(15) Connect the electrical connectors (2) and (21) as follows: (a) Remove the CAP-BLANKING from each electrical connector and receptacle.
(b) Remove the protective caps (20) from the cartridges (22).
(c) Connect the electrical connectors (21) to the cartridges (22).
(d) Connect the electrical connector (2) to the pressure switch (3).
WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(16) Safety the electrical connectors (21) with (17) Put the eye-end of the tie-rod (10) in position between the lugs of the fire extinguisher bottle (1).
(18) If necessary, adjust the tie-rod as follows:
(a) Loosen the lock nut (11) and remove the eye-end of the tie-rod (10) from the rod-end (13).
(b) Remove and discard the lock washer (12).
(c) Install the new AIPC 26-23-04-07-090 LOCK WASHER (12) or AIPC 26-23-84-07-245 LOCK WASHER (12) and the eye-end of the tie-rod (10) on the rod-end (13).
(d) Adjust the tie-rod (10) until the bolt (9) goes through the eye-end of the tie-rod (10) and the lugs that are on the fire extinguisher bottle (1).
(e) Tighten the lock nut (11).
(f) Safety the lock nut (11) with the lock washer (12).
(19) Install the bolt (9) and the nut (8).
A. Installation of the Cargo Fire-Extinguisher Bottle
(1) Apply Polysulfide Sealant-General Purpose Interfay - (Material No.06AAC1) to the upper brackets of the fire extinguisher bottle (1)
(2) Install the fire extinguisher bottle (1) as follows:
(b) Install the bolts (7), the washers (17) and the nuts (18).
(3) Remove the blanking plugs from:
(5) If the discharge heads (20) are not aligned, do the steps that follow:
(b) Loosen the coupling nuts (19).
(c) Align the discharge heads (20) with the flexible hoses (4).
(d) TORQUE the coupling nuts (19) to between 6.8 and 5.4 m.daN (50.15 and 39.82 lbf.ft )
.
(e) Safety the coupling nuts (19) with14QFB1 Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - .
(7) Connect the flexible hose (13) to the safety relief valve (15).
(8) TORQUE the nut (14) to between 1.7 and 1.5 m.daN (12.54 and 11.06 lbf.ft )
.
(9) Connect the flexible hoses (4) to the discharge heads (20).
(10) TORQUE the nuts (5) to between 4.3 and 3.9 m.daN (31.71 and 28.76 lbf.ft )
.
(11) Install the bonding straps (25) and the nuts (24) on the ground lug bolts (26) (Ref. AMM TASK 20-28-00-912-802).
(12) TORQUE the nuts (24) to between 0.35 and 0.3 m.daN (30.97 and 26.55 lbf.in )
.
(13) Make sure that you are grounded with the ELECTRICALLY GROUNDED WRIST STRAP.
14QFB1 Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - .
(a) Remove the CAP-BLANKING from each electrical connector and receptacle.
(b) Remove the protective caps (21) from the cartridges (23).
(c) Connect the electrical connectors (22) to the cartridges (23).
(d) Connect the electrical connector (2) to the pressure switch (3).
14QEB1 Wire-Locking Dia: 0.6 mm CRES Nickel Alloy - .
(17) Put the eye-end of the tie-rod (9) in position between the lugs of the fire extinguisher bottle (1).
(18) If necessary, adjust the tie-rod (9) as follows:
(a) Loosen the lock nut (10) and remove the eye-end of the tie-rod (9) from the rod-end (12).
(b) Remove and discard the lock washer (11).
(c) Install the new AIPC 26-23-04-07-090 LOCK WASHER (11) or AIPC 26-23-84-07-245 LOCK WASHER (11) and the eye-end of the tie-rod (9) on the rod-end (12).
(d) Adjust the tie-rod (9) until the bolt (6) goes through the eye-end of the tie-rod (9) and the lugs that are on the fire extinguisher bottle (1).
(e) Tighten the lock nut (10).
(f) Safety the lock nut (10) with the lock washer (11).
(19) Install the bolt (6) and the nut (8).
Subtask 26-23-42-420-050-K ** ON A/C NOT FOR ALL (1) Apply Polysulfide Sealant-General Purpose Interfay - (Material No.06AAC1) to the upper brackets of the fire extinguisher bottle (1)
(2) Install the fire extinguisher bottle (1) as follows:
WARNING:
BE VERY CAREFUL WHEN YOU MOVE A FULL FIRE EXTINGUISHER BOTTLE. A SUDDEN OR HEAVY SHOCK TO A FULL BOTTLE CAN CAUSE UNWANTED DISCHARGE AND INJURY TO PERSONS.
(a) Hold the fire extinguisher bottle (1) in its correct installation position on the structure (16). (b) Install the bolts (7), the washers (17) and the nuts (18).
(3) Remove the blanking plugs from:
- The disconnected line ends
- The safety relief valve (15)
- The discharge heads (20).
(5) If the discharge heads (20) are not aligned, do the steps that follow:
WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(a) Remove and discard the lockwire. (b) Loosen the coupling nuts (19).
(c) Align the discharge heads (20) with the flexible hoses (4).
(d) TORQUE the coupling nuts (19) to between 6.8 and 5.4 m.daN (50.15 and 39.82 lbf.ft )
.(e) Safety the coupling nuts (19) with
CAUTION:
APPLY A SMALL QUANTITY OF THE CORRECT GREASE TO THE MALE THREADS OF THE CONNECTIONS. THIS WILL PREVENT DAMAGE TO THE THREADS.
MAKE SURE THAT GREASE DOES NOT GO INTO THE PIPES. GREASE IN THE PIPES CAN CAUSE A MALFUNCTION OF THE SYSTEM.
(6) Apply a small quantity of Synthetic Oil base Grease-Fuel and Oxidized Environment Fluorinated - (Material No.03GEE1) to the male threads of the safety relief valve (15) and the discharge heads (20). (7) Connect the flexible hose (13) to the safety relief valve (15).
(8) TORQUE the nut (14) to between 1.7 and 1.5 m.daN (12.54 and 11.06 lbf.ft )
. (9) Connect the flexible hoses (4) to the discharge heads (20).
(10) TORQUE the nuts (5) to between 4.3 and 3.9 m.daN (31.71 and 28.76 lbf.ft )
. (11) Install the bonding straps (25) and the nuts (24) on the ground lug bolts (26) (Ref. AMM TASK 20-28-00-912-802).
(12) TORQUE the nuts (24) to between 0.35 and 0.3 m.daN (30.97 and 26.55 lbf.in )
. (13) Make sure that you are grounded with the ELECTRICALLY GROUNDED WRIST STRAP.
WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(14) Safety the cartridges (23) with WARNING:
BEFORE YOU TOUCH THE POWER DEVICE CARTRIDGE, MAKE SURE THAT YOU ARE GROUNDED AND THAT YOU INSTALL A SHUNT DEVICE ON IT. USE A CAP OR PLUG AS SHUNT DEVICE (THE CAP OR PLUG WILL SHUNT THE PINS TOGETHER ON THE CARTRIDGE). DO NOT USE A FOIL SHUNT.
IF YOU TOUCH A POWER DEVICE CARTRIDGE THAT DOES NOT HAVE A SHUNT DEVICE INSTALLED, AN EXPLOSION CAN OCCUR AND CAUSE INJURIES TO YOU.
CAUTION:
MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
CAUTION:
REFER TO THE MATCH MARKS MADE DURING THE REMOVAL WHEN YOU CONNECT THE ELECTRICAL WIRES.
INCORRECT CONNECTION OF THE WIRES WILL CAUSE DAMAGE TO EQUIPMENT.
CAUTION:
MAKE SURE THAT THE BONDING STRAP(S) IS(ARE) CONNECTED BEFORE YOU CONNECT THE ELECTRICAL WIRE(S).
(15) Connect the electrical connectors (2) and (22) as follows: (a) Remove the CAP-BLANKING from each electrical connector and receptacle.
(b) Remove the protective caps (21) from the cartridges (23).
(c) Connect the electrical connectors (22) to the cartridges (23).
(d) Connect the electrical connector (2) to the pressure switch (3).
WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(16) Safety the electrical connectors (22) with (17) Put the eye-end of the tie-rod (9) in position between the lugs of the fire extinguisher bottle (1).
(18) If necessary, adjust the tie-rod (9) as follows:
(a) Loosen the lock nut (10) and remove the eye-end of the tie-rod (9) from the rod-end (12).
(b) Remove and discard the lock washer (11).
(c) Install the new AIPC 26-23-04-07-090 LOCK WASHER (11) or AIPC 26-23-84-07-245 LOCK WASHER (11) and the eye-end of the tie-rod (9) on the rod-end (12).
(d) Adjust the tie-rod (9) until the bolt (6) goes through the eye-end of the tie-rod (9) and the lugs that are on the fire extinguisher bottle (1).
(e) Tighten the lock nut (10).
(f) Safety the lock nut (10) with the lock washer (11).
(19) Install the bolt (6) and the nut (8).
A. Installation of the Cargo Fire-Extinguisher Bottle
(2) Hold the fire extinguisher bottle (1) in its correct installation position on the structure (16).
(3) Install the bolts (7), the washers (17) and the nuts (18).
(4) TORQUE the nuts (18) to between 1.79 and 1.38 m.daN (13.20 and 10.18 lbf.ft )
.
(5) Remove the blanking plugs from:
(7) If the discharge heads (20) are not aligned, do the steps that follow:
(b) Loosen the coupling nuts (19).
(c) Align the discharge heads (20) with the flexible hoses (4).
(d) TORQUE the coupling nuts (19) to between 7.5 and 6.1 m.daN (55.31 and 44.98 lbf.ft )
.
(e) Safety the coupling nuts (19) with the14QGC1 Wire-Locking Dia: 1 mm (0.041 inch) CRES - .
(9) Connect the flexible hose (13) to the safety relief valve (15).
(10) TORQUE the nut (14) to between 1.3 and 1.2 m.daN (115.04 and 106.19 lbf.in )
.
(11) Connect the flexible hoses (4) to the discharge heads (20).
(12) TORQUE the nuts (5) to between 4.3 and 3.9 m.daN (31.71 and 28.76 lbf.ft )
.
(13) Install the bonding straps (25) and the nuts (24) on the ground lug bolts (26) (Ref. AMM TASK 20-28-00-912-802).
(14) TORQUE the nuts (24) to between 0.35 and 0.3 m.daN (30.97 and 26.55 lbf.in )
.
(15) Make sure that you are grounded with the ELECTRICALLY GROUNDED WRIST STRAP.
14QFB1 Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - .
(a) Remove the CAP-BLANKING from each electrical connector and receptacle.
(b) Connect the electrical connector (2) to the pressure switch (3).
(c) Remove the protective caps (22) from the cartridges (21) and connect the electrical connectors (23) to the cartridges (21).
14QEB1 Wire-Locking Dia: 0.6 mm CRES Nickel Alloy - .
(18) Put the eye-end of the tie-rod (9) in position between the lugs of the fire extinguisher bottle (1).
(19) If necessary, adjust the tie-rod (9) as follows:
(a) Loosen the locknut (10) and remove the eye-end of the tie-rod (9) from the rod-end (12).
(b) Unfold the lugs of the lockwasher (11).
(c) Remove and discard the lockwasher (11).
(d) Install the new AIPC 26-23-04-07-175 WASHER (11) or AIPC 26-23-84-07-245 WASHER (11) and the eye-end of the tie-rod (9) on the rod-end (12).
(e) Adjust the tie-rod (9) until the bolt (6) goes through the eye-end of the tie-rod (9) and the lugs on the fire extinguisher bottle (1).
(f) Tighten the locknut (10).
(g) Safety the locknut (10) with the lockwasher (11).
(20) Install the bolt (6) and the nut (8).
(21) TORQUE the nut (8) to between 1.06 and 0.82 m.daN (93.81 and 72.57 lbf.in )
.
Subtask 26-23-42-865-052-A ** ON A/C NOT FOR ALL WARNING:
BE VERY CAREFUL WHEN YOU MOVE A FULL FIRE EXTINGUISHER BOTTLE. A SUDDEN OR HEAVY SHOCK TO A FULL BOTTLE CAN CAUSE UNWANTED DISCHARGE AND INJURY TO PERSONS.
(1) Apply Polysulfide Sealant-General Purpose Interfay - (Material No.06AAC1) to the upper brackets of the fire extinguisher bottle (1). (2) Hold the fire extinguisher bottle (1) in its correct installation position on the structure (16).
(3) Install the bolts (7), the washers (17) and the nuts (18).
(4) TORQUE the nuts (18) to between 1.79 and 1.38 m.daN (13.20 and 10.18 lbf.ft )
. (5) Remove the blanking plugs from:
- The disconnected line ends
- The safety relief valve (15)
- The discharge heads (20).
(7) If the discharge heads (20) are not aligned, do the steps that follow:
WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(a) Remove and discard the lockwire. (b) Loosen the coupling nuts (19).
(c) Align the discharge heads (20) with the flexible hoses (4).
(d) TORQUE the coupling nuts (19) to between 7.5 and 6.1 m.daN (55.31 and 44.98 lbf.ft )
. (e) Safety the coupling nuts (19) with the
CAUTION:
APPLY A SMALL QUANTITY OF THE CORRECT GREASE TO THE MALE THREADS OF THE CONNECTIONS. THIS WILL PREVENT DAMAGE TO THE THREADS.
MAKE SURE THAT GREASE DOES NOT GO INTO THE PIPES. GREASE IN THE PIPES CAN CAUSE A MALFUNCTION OF THE SYSTEM.
(8) Apply a small quantity of Synthetic Oil base Grease-Fuel and Oxidized Environment Fluorinated - (Material No.03GEE1) to the male threads of the safety relief valve (15) and the discharge heads (20). (9) Connect the flexible hose (13) to the safety relief valve (15).
(10) TORQUE the nut (14) to between 1.3 and 1.2 m.daN (115.04 and 106.19 lbf.in )
. (11) Connect the flexible hoses (4) to the discharge heads (20).
(12) TORQUE the nuts (5) to between 4.3 and 3.9 m.daN (31.71 and 28.76 lbf.ft )
. (13) Install the bonding straps (25) and the nuts (24) on the ground lug bolts (26) (Ref. AMM TASK 20-28-00-912-802).
(14) TORQUE the nuts (24) to between 0.35 and 0.3 m.daN (30.97 and 26.55 lbf.in )
. (15) Make sure that you are grounded with the ELECTRICALLY GROUNDED WRIST STRAP.
WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(16) Safety the cartridges (21) with WARNING:
BEFORE YOU TOUCH THE POWER DEVICE CARTRIDGE, MAKE SURE THAT YOU ARE GROUNDED AND THAT YOU INSTALL A SHUNT DEVICE ON IT. USE A CAP OR PLUG AS SHUNT DEVICE (THE CAP OR PLUG WILL SHUNT THE PINS TOGETHER ON THE CARTRIDGE). DO NOT USE A FOIL SHUNT.
IF YOU TOUCH A POWER DEVICE CARTRIDGE THAT DOES NOT HAVE A SHUNT DEVICE INSTALLED, AN EXPLOSION CAN OCCUR AND CAUSE INJURIES TO YOU.
CAUTION:
MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
CAUTION:
REFER TO THE MATCH MARKS MADE DURING THE REMOVAL WHEN YOU CONNECT THE ELECTRICAL WIRES.
INCORRECT CONNECTION OF THE WIRES WILL CAUSE DAMAGE TO EQUIPMENT.
CAUTION:
MAKE SURE THAT THE BONDING STRAP(S) IS(ARE) CONNECTED BEFORE YOU CONNECT THE ELECTRICAL WIRE(S).
(17) Connect the electrical connectors as follows: (a) Remove the CAP-BLANKING from each electrical connector and receptacle.
(b) Connect the electrical connector (2) to the pressure switch (3).
(c) Remove the protective caps (22) from the cartridges (21) and connect the electrical connectors (23) to the cartridges (21).
WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(d) Safety the electrical connectors (23) with the (18) Put the eye-end of the tie-rod (9) in position between the lugs of the fire extinguisher bottle (1).
(19) If necessary, adjust the tie-rod (9) as follows:
(a) Loosen the locknut (10) and remove the eye-end of the tie-rod (9) from the rod-end (12).
(b) Unfold the lugs of the lockwasher (11).
(c) Remove and discard the lockwasher (11).
(d) Install the new AIPC 26-23-04-07-175 WASHER (11) or AIPC 26-23-84-07-245 WASHER (11) and the eye-end of the tie-rod (9) on the rod-end (12).
(e) Adjust the tie-rod (9) until the bolt (6) goes through the eye-end of the tie-rod (9) and the lugs on the fire extinguisher bottle (1).
(f) Tighten the locknut (10).
(g) Safety the locknut (10) with the lockwasher (11).
(20) Install the bolt (6) and the nut (8).
(21) TORQUE the nut (8) to between 1.06 and 0.82 m.daN (93.81 and 72.57 lbf.in )
.B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 26-23-42-710-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/CARGO FIRE/EXTIG/BTL2 | 8WX | C04 |
| 49VU | AIR COND/CARGO FIRE/EXTIG/BTL1 | 1WX | C03 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/CARGO/FIRE/EXTIG | 1WX | T19 |
C. Test
(1) Do the operational test of the cargo-compartment smoke-detection system (Ref. AMM TASK 26-16-00-710-001).
5. Close-up(1) Do the operational test of the cargo-compartment smoke-detection system (Ref. AMM TASK 26-16-00-710-001).
Subtask 26-23-42-410-050-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the sidewall panel 162AW (Ref. AMM TASK 25-55-12-400-003).
(3) Set the CARGO COMPT LIGHT switch 8LU to the OFF position.
(4) Close the aft cargo-compartment door 826 (Ref. AMM TASK 52-30-00-860-002).
Subtask 26-23-42-410-050-B ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the sidewall panel 162AW (Ref. AMM TASK 25-55-12-400-003).
(3) Set the CARGO COMPT LIGHT switch 8LU to the OFF position.
(4) Close the aft cargo-compartment door 826 (Ref. AMM TASK 52-30-00-860-002).
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the partition panel 161DW (Ref. AMM TASK 25-55-12-400-001).
(3) Set the CARGO COMPT LIGHT switch 8LU to the OFF position.
(4) Close the aft cargo-compartment door 826 (Ref. AMM TASK 52-30-00-860-002).
Subtask 26-23-42-862-050-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the partition panel 161DW (Ref. AMM TASK 25-55-12-400-001).
(3) Set the CARGO COMPT LIGHT switch 8LU to the OFF position.
(4) Close the aft cargo-compartment door 826 (Ref. AMM TASK 52-30-00-860-002).
B. Put the aircraft back to its initial configuration.
(1) De-energize the ground service network (Ref. AMM TASK 24-42-00-862-001).
(1) De-energize the ground service network (Ref. AMM TASK 24-42-00-862-001).
Cargo Fire-Extinguisher Bottle