Remove Cargo Compartment Fire-Extinguisher for in-shop Hydrostatic Test and Check of Pressure Switch Setting
TASK 26-23-42-280-002-A
Remove Cargo Compartment Fire-Extinguisher for in-shop Hydrostatic Test and Check of Pressure Switch Setting
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Work Zones and Access Panels
B. Referenced Information
3. Job Set-up
Subtask 26-23-42-020-054-A ** ON A/C NOT FOR ALL
Subtask 26-23-42-280-051-A ** ON A/C NOT FOR ALL
Subtask 26-23-42-420-055-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 23:46:47 UTC
Remove Cargo Compartment Fire-Extinguisher for in-shop Hydrostatic Test and Check of Pressure Switch Setting
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 162 | BULK CARGO COMPARTMENT |
| 172 | AFT CABIN U/FLOOR COMPARTMENT |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 26-23-42-000-001-A | Removal of the Cargo Fire-Extinguisher Bottle |
| TASK 26-23-42-400-001-A | Installation of the Cargo Fire-Extinguisher Bottle |
Subtask 26-23-42-020-054-A ** ON A/C NOT FOR ALL
A. Removal of the Fire Extinguisher Bottle
(1) Remove the fire extinguisher bottle (Ref. AMM TASK 26-23-42-000-001).
4. Procedure(1) Remove the fire extinguisher bottle (Ref. AMM TASK 26-23-42-000-001).
Subtask 26-23-42-280-051-A ** ON A/C NOT FOR ALL
A. Hydrostatic Test and Check of Pressure Switch Setting
(1) Send the related fire extinguisher bottle to the workshop for the hydrostatic test and do the check of pressure switch position.
5. Close-up(1) Send the related fire extinguisher bottle to the workshop for the hydrostatic test and do the check of pressure switch position.
Subtask 26-23-42-420-055-A ** ON A/C NOT FOR ALL
A. Installation of the Fire Extinguisher Bottle
(1) Install a serviceable fire extinguisher bottle (Ref. AMM TASK 26-23-42-400-001).