Installation of the Cargo Fire-Extinguisher Bottle
TASK 26-23-41-400-004-B
Installation of the Cargo Fire-Extinguisher Bottle
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Expendable Parts
E. Referenced Information
3. Job Set-up
Subtask 26-23-41-941-061-A ** ON A/C NOT FOR ALL
Subtask 26-23-41-790-050-A ** ON A/C NOT FOR ALL
Subtask 26-23-41-410-058-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:15:22 UTC
Installation of the Cargo Fire-Extinguisher Bottle
WARNING:
BE CAREFUL WHEN YOU REMOVE OR INSTALL THIS EQUIPMENT. THIS EQUIPMENT IS HEAVY (MORE THAN 12 KG (26.5 lb)) AND CAN CAUSE INJURY AND/OR DAMAGE.
WARNING:
MAKE SURE THAT THE MAXIMUM PERMITTED LIFE (MPL) OF THE CARTRIDGE IS LONGER THAN THE TIME TO THE NEXT SCHEDULED DISCARD OF THE CARTRIDGE.
WARNING:
IF YOU REMOVE THE FIRE EXTINGUISHER BOTTLES IN A CLOSED HANGAR, MAKE SURE THAT THERE IS A FLOW OF NEW AIR IN THE HANGAR.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
CAUTION:
BEFORE YOU INSTALL/REMOVE THE GSE-TOOL, READ THE INSTRUCTIONS IN THE APPLICABLE GSE INSTRUCTION MANUAL. WHILE YOU OPERATE THIS TOOL, CAREFULLY OBEY THEM. IF YOU DO NOT OBEY THE INSTRUCTIONS, DAMAGE TO EQUIPMENT CAN OCCUR.
1. Reason for the JobNOTE: Two personsare necessary to do this task.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ELECTRICALLY GROUNDED WRIST STRAP |
| No specific | AR | INSTALLATION TOOL - TIE WRAP |
| No specific | Torque wrench: range to between 1.7 and 1.5 m.daN (12.54 and 11.06 lbf.ft ) ![]() | |
| No specific | Torque wrench: range to between 4.3 and 3.9 m.daN (31.71 and 28.76 lbf.ft ) ![]() | |
| No specific | Torque wrench: range to between 6.8 and 5.4 m.daN (50.15 and 39.82 lbf.ft ) ![]() | |
| 10-101950-81 | AR | SHUNT PLUG-FIRE EXTINGUISHER CARTRIDGE,HTL |
| 98D26208003000 | 1 | DEV- R-I,FIRE EXT BOTTLE A321ACF |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.03GEE1) | Synthetic Oil base Grease-Fuel and Oxidized Environment Fluorinated - |
| (Material No.06AAC1) | Polysulfide Sealant-General Purpose Interfay - |
| (Material No.14QFB1) | Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 130 | FWD CARGO COMPT AFT BULKHEAD OF AVNCS COMPT TO FWD PRESSURE BULKHEAD OF WING CENTER BOX |
| 131CC, 231VF | |
| 132MW, 825 |
| FIG.ITEM | DESIGNATION | IPC-CSN |
|---|---|---|
| 12 | LOCK WASHER | AIPC 26-23-02-02-100 |
| 39 | LOCK WASHER | AIPC 26-23-02-02-100 |
| 12 | WASHER | AIPC 26-23-82-02-150 |
| 39 | WASHER | AIPC 26-23-82-02-150 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 20-28-00-912-802-A | Electrical Bonding - General Maintenance Procedure |
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 25-54-12-000-002-A | Removal of the Ceiling Panels in the Forward Cargo Compartment |
| TASK 25-54-12-000-003-A | Removal of the Sidewall Panels in the Forward Cargo Compartment |
| TASK 25-54-12-400-002-A | Installation of the Ceiling Panels in the Forward Cargo Compartment |
| TASK 25-54-12-400-003-A | Installation of the Sidewall Panels in the Forward Cargo Compartment |
| TASK 26-16-00-710-001-A | Operational Check of Cargo Compartment Smoke Detection by PTT |
| TASK 26-23-00-200-004-A | Check of the Fire Extinguishing Lines of the Two Fire Extinguisher Bottles for Leakage and Blockage |
| TASK 26-23-00-200-005-A | Restoration of the Fire Extinguishing System (FES) after Activation |
| TASK 26-23-14-000-001-A | Removal of the Halon Filter |
| TASK 26-23-14-400-001-A | Installation of the Halon Filter |
| TASK 26-23-41-280-001-A | Remove Cargo Compartment Fire Extinguisher Bottle for in shop Weight Check. |
| TASK 26-23-41-280-001-B | Remove Cargo Compartment Fire Extinguisher Bottle for in shop Weight Check. |
| TASK 26-23-41-400-005-A | Installation of the Cartridge of the Cargo Fire-Extinguisher Bottle |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 52-30-00-860-002-A | Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 53-22-12-000-001-A | Removal of the Cabin Floor Panels |
| TASK 53-22-12-400-001-A | Installation of the Cabin Floor Panels |
Subtask 26-23-41-941-061-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) If the installation of the cargo fire-extinguisher bottle is done after a discharge of the fire extinguishing agent:
Subtask 26-23-41-860-051-A ** ON A/C NOT FOR ALL (1) If the installation of the cargo fire-extinguisher bottle is done after a discharge of the fire extinguishing agent:
- do the restoration of the fire extinguishing system after activation (Ref. AMM TASK 26-23-00-200-005).
B. Aircraft Maintenance Configuration
(1) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
Subtask 26-23-41-010-062-A ** ON A/C NOT FOR ALL (1) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
C. Get Access
(1) Make sure that the forward cargo-compartment door 825 is open (Ref. AMM TASK 52-30-00-860-001).
(2) Make sure that the CARGO COMPT LIGHT switch 6LU is in the ON position.
(3) Make sure that the sidewall panel 132MW is removed (Ref. AMM TASK 25-54-12-000-003).
(4) Make sure that the cartridge is installed on the fire extinguisher bottle (Ref. AMM TASK 26-23-41-400-005).
(5) Make sure that the protective cap is installed on the cartridge.
(6) Clean the component interfaces and the adjacent area.
(7) Do an inspection of the component interfaces and the adjacent area.
Subtask 26-23-41-010-062-C ** ON A/C NOT FOR ALL (1) Make sure that the forward cargo-compartment door 825 is open (Ref. AMM TASK 52-30-00-860-001).
(2) Make sure that the CARGO COMPT LIGHT switch 6LU is in the ON position.
(3) Make sure that the sidewall panel 132MW is removed (Ref. AMM TASK 25-54-12-000-003).
(4) Make sure that the cartridge is installed on the fire extinguisher bottle (Ref. AMM TASK 26-23-41-400-005).
(5) Make sure that the protective cap is installed on the cartridge.
(6) Clean the component interfaces and the adjacent area.
(7) Do an inspection of the component interfaces and the adjacent area.
C. Get Access
(1) Make sure that the forward cargo-compartment door 825 is open (Ref. AMM TASK 52-30-00-860-001).
(2) Make sure that the CARGO COMPT LIGHT switch 6LU is in the ON position.
(3) Make sure that the sidewall panel 132MW is removed (Ref. AMM TASK 25-54-12-000-003).
(4) Make sure that the cartridge is installed on the fire extinguisher bottle (Ref. AMM TASK 26-23-41-400-005).
(5) Make sure that the protective cap is installed on the cartridge.
(6) Clean the component interfaces and the adjacent area.
(7) Do an inspection of the component interfaces and the adjacent area.
Subtask 26-23-41-010-062-D ** ON A/C NOT FOR ALL (1) Make sure that the forward cargo-compartment door 825 is open (Ref. AMM TASK 52-30-00-860-001).
(2) Make sure that the CARGO COMPT LIGHT switch 6LU is in the ON position.
(3) Make sure that the sidewall panel 132MW is removed (Ref. AMM TASK 25-54-12-000-003).
(4) Make sure that the cartridge is installed on the fire extinguisher bottle (Ref. AMM TASK 26-23-41-400-005).
(5) Make sure that the protective cap is installed on the cartridge.
(6) Clean the component interfaces and the adjacent area.
(7) Do an inspection of the component interfaces and the adjacent area.
C. Get Access
(1) If an Additional Center Tank (ACT) is installed:
(a) Make sure that cabin floor panel 231VF is removed (Ref. AMM TASK 53-22-12-000-001).
(b) Make sure that ceiling panel 131CC is removed (Ref. AMM TASK 25-54-12-000-002).
(c) Make sure that sidewall panel 132MW is removed (Ref. AMM TASK 25-54-12-000-003).
(2) If the ACT is not installed:
(a) Make sure that forward cargo compartment door 825 is open (Ref. AMM TASK 52-30-00-860-001).
(b) Make sure that CARGO COMPT LIGHT switch 6LU is in the ON position.
(c) Make sure that sidewall panel 132MW is removed (Ref. AMM TASK 25-54-12-000-003).
(3) Make sure that the shunt plugs are installed on the cartridges.
Subtask 26-23-41-280-059-A ** ON A/C NOT FOR ALL (1) If an Additional Center Tank (ACT) is installed:
(a) Make sure that cabin floor panel 231VF is removed (Ref. AMM TASK 53-22-12-000-001).
(b) Make sure that ceiling panel 131CC is removed (Ref. AMM TASK 25-54-12-000-002).
(c) Make sure that sidewall panel 132MW is removed (Ref. AMM TASK 25-54-12-000-003).
(2) If the ACT is not installed:
(a) Make sure that forward cargo compartment door 825 is open (Ref. AMM TASK 52-30-00-860-001).
(b) Make sure that CARGO COMPT LIGHT switch 6LU is in the ON position.
(c) Make sure that sidewall panel 132MW is removed (Ref. AMM TASK 25-54-12-000-003).
(3) Make sure that the shunt plugs are installed on the cartridges.
D. Weight Check
(1) Do a weight check of the cargo fire-extinguisher bottle (Ref. AMM TASK 26-23-41-280-001).
Subtask 26-23-41-865-070-A ** ON A/C NOT FOR ALL (1) Do a weight check of the cargo fire-extinguisher bottle (Ref. AMM TASK 26-23-41-280-001).
NOTE: If the cargo fire-extinguisher bottle was weighed in a short time before this installation it is not necessary to weigh it again.
E. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/CARGO FIRE/EXTIG/BTL2 | 8WX | C05 |
| 49VU | AIR COND/CARGO/FIRE/EXTIG/BTL1 | 1WX | C04 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/CARGO FIRE/EXTIG/BTL2 | 8WX | C04 |
| 49VU | AIR COND/CARGO/FIRE/EXTIG/BTL1 | 1WX | C03 |
Subtask 26-23-41-790-050-A ** ON A/C NOT FOR ALL
A. Leak Test
(1) Do the leak test for the fire extinguisher bottle (4010WX). To do this:
(a) Install the halon filters (5010WM and 5011WM), if removed (Ref. AMM TASK 26-23-14-400-001).
(b) Do the leak test of the fire extinguisher system (Ref. AMM TASK 26-23-00-200-004).
Subtask 26-23-41-420-060-A ** ON A/C NOT FOR ALL (1) Do the leak test for the fire extinguisher bottle (4010WX). To do this:
(a) Install the halon filters (5010WM and 5011WM), if removed (Ref. AMM TASK 26-23-14-400-001).
(b) Do the leak test of the fire extinguisher system (Ref. AMM TASK 26-23-00-200-004).
B. Installation of the Cargo Fire-Extinguisher Bottle
(a) Apply Polysulfide Sealant-General Purpose Interfay - (Material No.06AAC1) to the upper brackets of the fire extinguisher bottle (1).
(b) Hold the fire extinguisher bottle (1) in its correct installation position on the structure (17).
(c) Install the bolts (18), the washers (7) and the nuts (6).
(d) Tighten the nuts (6).
(e) Remove the blanking plugs from:
(g) If the discharge heads (20) are not aligned, do the steps that follow:
2 Loosen the coupling nuts (19).
3 Align the discharge heads (20) with the flexible hoses (4).
4 TORQUE the coupling nuts (19) to between 6.8 and 5.4 m.daN (50.15 and 39.82 lbf.ft )
.
5 Safety the coupling nuts (19) with the14QFB1 Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - .
(i) Connect the flexible hose (14) to the safety relief valve (16).
(j) TORQUE the nut (15) to between 1.7 and 1.5 m.daN (12.54 and 11.06 lbf.ft )
.
(k) Connect the flexible hoses (4) to the discharge heads (20).
(l) TORQUE the nuts (5) to between 4.3 and 3.9 m.daN (31.71 and 28.76 lbf.ft )
.
(m) Install the bonding straps (25) and the nuts (24) on the ground lug bolts (26) (Ref. AMM TASK 20-28-00-912-802).
(n) Tighten the nuts (24).
(o) Make sure that you are grounded with the ELECTRICALLY GROUNDED WRIST STRAP.
1 Remove the CAP-BLANKING from each electrical connector and receptacle.
2 Connect the electrical connector (2) to the pressure switch (3).
3 Remove the protective caps (21) from the cartridges (23).
4 Connect the electrical connectors (22) to the cartridges (23).
(q) Put the eye-end of the tie-rod (9) in position between the lugs on the fire extinguisher bottle (1).
(r) If necessary, adjust the tie-rod (9) as follows:
1 Loosen the locknut (11) and remove the eye-end of the tie-rod (9) from the rod-end (13).
2 Unfold the lugs of the lock washer (12).
3 Remove and discard the lock washer (12).
4 Install the new AIPC 26-23-02-02-100 LOCK WASHER (12) or AIPC 26-23-82-02-150 WASHER (12) and the eye-end of the tie-rod (9) on the rod-end (13).
5 Adjust the tie-rod (9) until the bolt (10) goes through the eye-end of the tie-rod (9) and the lugs on the fire extinguisher bottle (1).
6 Tighten the locknut (11).
7 Safety the locknut (11) with the lock washer (12).
(s) Install the bolt (10) and the nut (8).
(t) Tighten the nut (8).
(2) Install the fire extinguisher bottle (27) (4010WX) as follows:
(a) Apply Polysulfide Sealant-General Purpose Interfay - (Material No.06AAC1) to the upper brackets of the fire extinguisher bottle (27).
(b) Remove the halon filters (5010WM and 5011WM) from their brackets as follows:
1 Remove the three screws and the washers from the halon filters (Ref. AMM TASK 26-23-14-000-001).
2 Use the INSTALLATION TOOL - TIE WRAP to attach the halon filters to their brackets. This prevents the halon filters to fall.
3 Push the halon filters until the rigid pipe (30) moves away from the fire extinguisher bottle (27).
(c) Hold the fire extinguisher bottle (27) in its correct installation position on the structure (44).
(d) Install the bolts (45), the washers (34) and the nuts (33).
(e) Tighten the nuts (33).
(f) Install the halon filters (5010WM and 5011WM) on their brackets as follows:
1 Move the halon filters until the rigid pipes (30) align with the fire extinguisher bottle (27).
2 Hold the halon filters and remove the INSTALLATION TOOL - TIE WRAP.
3 Install the three screws and the washers on the halon filters (Ref. AMM TASK 26-23-14-400-001).
(g) Remove the blanking plugs from:
(i) If the discharge heads (32) are not aligned, do the steps that follow:
2 Loosen the coupling nuts (46).
3 Align the discharge heads (32) with the rigid pipes (30).
4 TORQUE the coupling nuts (32) to between 6.8 and 5.4 m.daN (50.15 and 39.82 lbf.ft )
.
5 Safety the coupling nuts (32) with the14QFB1 Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - .
(k) Connect the flexible hose (41) to the safety relief valve (43).
(l) TORQUE the nut (42) to between 1.7 and 1.5 m.daN (12.54 and 11.06 lbf.ft )
.
(m) Connect the rigid pipes (30) to the discharge heads (32).
(n) TORQUE the nuts (31) to between 4.3 and 3.9 m.daN (31.71 and 28.76 lbf.ft )
.
(o) Install the bonding straps (51) and the nuts (50) on the ground lug bolts (52) (Ref. AMM TASK 20-28-00-912-802).
(p) Tighten the nuts (50).
(q) Make sure that you are grounded with the ELECTRICALLY GROUNDED WRIST STRAP.
1 Remove the CAP-BLANKING from each electrical connector and receptacle.
2 Connect the electrical connector (28) to the pressure switch (29).
3 Remove the 10-101950-81 SHUNT PLUG-FIRE EXTINGUISHER CARTRIDGE,HTL (47) from the cartridges (49).
4 Connect the electrical connectors (48) to the cartridges (49).
(s) Put the eye-end of the tie-rod (36) in position between the lugs on the fire extinguisher bottle (27).
(t) If necessary, adjust the tie-rod (36) as follows:
1 Loosen the locknut (38) and remove the eye-end of the tie-rod (36) from the rod-end (40).
2 Unfold the lugs of the lock washer (12).
3 Remove and discard the lock washer (39).
4 Install the new AIPC 26-23-02-02-100 LOCK WASHER (39) or AIPC 26-23-82-02-150 WASHER (39) and the eye-end of the tie-rod (36) on the rod-end (40).
5 Adjust the tie-rod (36) until the bolt (37) goes through the eye-end of the tie-rod (36) and the lugs on the fire extinguisher bottle (27).
6 Tighten the locknut (38).
7 Safety the locknut (38) with the lock washer (39).
(u) Install the bolt (37) and the nut (35).
(v) Tighten the nut (35).
Subtask 26-23-41-420-060-B ** ON A/C NOT FOR ALL WARNING:
BE VERY CAREFUL WHEN YOU MOVE A FULL FIRE EXTINGUISHER BOTTLE. A SUDDEN OR HEAVY SHOCK TO A FULL BOTTLE CAN CAUSE UNWANTED DISCHARGE AND INJURY TO PERSONS.
(1) Install the fire extinguisher bottle (4005WX) as follows: (a) Apply Polysulfide Sealant-General Purpose Interfay - (Material No.06AAC1) to the upper brackets of the fire extinguisher bottle (1).
(b) Hold the fire extinguisher bottle (1) in its correct installation position on the structure (17).
(c) Install the bolts (18), the washers (7) and the nuts (6).
(d) Tighten the nuts (6).
(e) Remove the blanking plugs from:
- The disconnected line ends
- The safety relief valve (16)
- The discharge heads (20).
(g) If the discharge heads (20) are not aligned, do the steps that follow:
WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
1 Remove and discard the lockwire. 2 Loosen the coupling nuts (19).
3 Align the discharge heads (20) with the flexible hoses (4).
4 TORQUE the coupling nuts (19) to between 6.8 and 5.4 m.daN (50.15 and 39.82 lbf.ft )
. 5 Safety the coupling nuts (19) with the
CAUTION:
APPLY A SMALL QUANTITY OF THE CORRECT GREASE TO THE MALE THREADS OF THE CONNECTIONS. THIS WILL PREVENT DAMAGE TO THE THREADS.
MAKE SURE THAT GREASE DOES NOT GO INTO THE PIPES. GREASE IN THE PIPES CAN CAUSE A MALFUNCTION OF THE SYSTEM.
(h) Apply a small quantity of Synthetic Oil base Grease-Fuel and Oxidized Environment Fluorinated - (Material No.03GEE1) to the male threads of the safety relief valve (16) and the discharge heads (20). (i) Connect the flexible hose (14) to the safety relief valve (16).
(j) TORQUE the nut (15) to between 1.7 and 1.5 m.daN (12.54 and 11.06 lbf.ft )
. (k) Connect the flexible hoses (4) to the discharge heads (20).
(l) TORQUE the nuts (5) to between 4.3 and 3.9 m.daN (31.71 and 28.76 lbf.ft )
. (m) Install the bonding straps (25) and the nuts (24) on the ground lug bolts (26) (Ref. AMM TASK 20-28-00-912-802).
(n) Tighten the nuts (24).
(o) Make sure that you are grounded with the ELECTRICALLY GROUNDED WRIST STRAP.
WARNING:
BEFORE YOU TOUCH THE POWER DEVICE CARTRIDGE, MAKE SURE THAT YOU ARE GROUNDED AND THAT YOU INSTALL A SHUNT DEVICE ON IT. USE A CAP OR PLUG AS SHUNT DEVICE (THE CAP OR PLUG WILL SHUNT THE PINS TOGETHER ON THE CARTRIDGE). DO NOT USE A FOIL SHUNT.
IF YOU TOUCH A POWER DEVICE CARTRIDGE THAT DOES NOT HAVE A SHUNT DEVICE INSTALLED, AN EXPLOSION CAN OCCUR AND CAUSE INJURIES TO YOU.
CAUTION:
MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
CAUTION:
MAKE SURE THAT THE BONDING STRAP(S) IS(ARE) CONNECTED BEFORE YOU CONNECT THE ELECTRICAL CONNECTOR(S).
(p) Connect the electrical connectors as follows: 1 Remove the CAP-BLANKING from each electrical connector and receptacle.
2 Connect the electrical connector (2) to the pressure switch (3).
3 Remove the protective caps (21) from the cartridges (23).
4 Connect the electrical connectors (22) to the cartridges (23).
(q) Put the eye-end of the tie-rod (9) in position between the lugs on the fire extinguisher bottle (1).
(r) If necessary, adjust the tie-rod (9) as follows:
1 Loosen the locknut (11) and remove the eye-end of the tie-rod (9) from the rod-end (13).
2 Unfold the lugs of the lock washer (12).
3 Remove and discard the lock washer (12).
4 Install the new AIPC 26-23-02-02-100 LOCK WASHER (12) or AIPC 26-23-82-02-150 WASHER (12) and the eye-end of the tie-rod (9) on the rod-end (13).
5 Adjust the tie-rod (9) until the bolt (10) goes through the eye-end of the tie-rod (9) and the lugs on the fire extinguisher bottle (1).
6 Tighten the locknut (11).
7 Safety the locknut (11) with the lock washer (12).
(s) Install the bolt (10) and the nut (8).
(t) Tighten the nut (8).
(2) Install the fire extinguisher bottle (27) (4010WX) as follows:
(a) Apply Polysulfide Sealant-General Purpose Interfay - (Material No.06AAC1) to the upper brackets of the fire extinguisher bottle (27).
(b) Remove the halon filters (5010WM and 5011WM) from their brackets as follows:
1 Remove the three screws and the washers from the halon filters (Ref. AMM TASK 26-23-14-000-001).
2 Use the INSTALLATION TOOL - TIE WRAP to attach the halon filters to their brackets. This prevents the halon filters to fall.
3 Push the halon filters until the rigid pipe (30) moves away from the fire extinguisher bottle (27).
(c) Hold the fire extinguisher bottle (27) in its correct installation position on the structure (44).
(d) Install the bolts (45), the washers (34) and the nuts (33).
(e) Tighten the nuts (33).
(f) Install the halon filters (5010WM and 5011WM) on their brackets as follows:
1 Move the halon filters until the rigid pipes (30) align with the fire extinguisher bottle (27).
2 Hold the halon filters and remove the INSTALLATION TOOL - TIE WRAP.
3 Install the three screws and the washers on the halon filters (Ref. AMM TASK 26-23-14-400-001).
(g) Remove the blanking plugs from:
- The disconnected line ends
- The safety relief valve (43)
- The discharge heads (32).
(i) If the discharge heads (32) are not aligned, do the steps that follow:
WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
1 Remove and discard the lockwire. 2 Loosen the coupling nuts (46).
3 Align the discharge heads (32) with the rigid pipes (30).
4 TORQUE the coupling nuts (32) to between 6.8 and 5.4 m.daN (50.15 and 39.82 lbf.ft )
. 5 Safety the coupling nuts (32) with the
CAUTION:
APPLY A SMALL QUANTITY OF THE CORRECT GREASE TO THE MALE THREADS OF THE CONNECTIONS. THIS WILL PREVENT DAMAGE TO THE THREADS.
MAKE SURE THAT GREASE DOES NOT GO INTO THE PIPES. GREASE IN THE PIPES CAN CAUSE A MALFUNCTION OF THE SYSTEM.
(j) Apply a small quantity of Synthetic Oil base Grease-Fuel and Oxidized Environment Fluorinated - (Material No.03GEE1) to the male threads of the safety relief valve (43) and the discharge heads (32). (k) Connect the flexible hose (41) to the safety relief valve (43).
(l) TORQUE the nut (42) to between 1.7 and 1.5 m.daN (12.54 and 11.06 lbf.ft )
. (m) Connect the rigid pipes (30) to the discharge heads (32).
(n) TORQUE the nuts (31) to between 4.3 and 3.9 m.daN (31.71 and 28.76 lbf.ft )
. (o) Install the bonding straps (51) and the nuts (50) on the ground lug bolts (52) (Ref. AMM TASK 20-28-00-912-802).
(p) Tighten the nuts (50).
(q) Make sure that you are grounded with the ELECTRICALLY GROUNDED WRIST STRAP.
WARNING:
BEFORE YOU TOUCH THE POWER DEVICE CARTRIDGE, MAKE SURE THAT YOU ARE GROUNDED AND THAT YOU INSTALL A SHUNT DEVICE ON IT. USE A CAP OR PLUG AS SHUNT DEVICE (THE CAP OR PLUG WILL SHUNT THE PINS TOGETHER ON THE CARTRIDGE). DO NOT USE A FOIL SHUNT.
IF YOU TOUCH A POWER DEVICE CARTRIDGE THAT DOES NOT HAVE A SHUNT DEVICE INSTALLED, AN EXPLOSION CAN OCCUR AND CAUSE INJURIES TO YOU.
CAUTION:
MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
CAUTION:
MAKE SURE THAT THE BONDING STRAP(S) IS(ARE) CONNECTED BEFORE YOU CONNECT THE ELECTRICAL CONNECTOR(S).
(r) Connect the electrical connectors as follows: 1 Remove the CAP-BLANKING from each electrical connector and receptacle.
2 Connect the electrical connector (28) to the pressure switch (29).
3 Remove the 10-101950-81 SHUNT PLUG-FIRE EXTINGUISHER CARTRIDGE,HTL (47) from the cartridges (49).
4 Connect the electrical connectors (48) to the cartridges (49).
(s) Put the eye-end of the tie-rod (36) in position between the lugs on the fire extinguisher bottle (27).
(t) If necessary, adjust the tie-rod (36) as follows:
1 Loosen the locknut (38) and remove the eye-end of the tie-rod (36) from the rod-end (40).
2 Unfold the lugs of the lock washer (12).
3 Remove and discard the lock washer (39).
4 Install the new AIPC 26-23-02-02-100 LOCK WASHER (39) or AIPC 26-23-82-02-150 WASHER (39) and the eye-end of the tie-rod (36) on the rod-end (40).
5 Adjust the tie-rod (36) until the bolt (37) goes through the eye-end of the tie-rod (36) and the lugs on the fire extinguisher bottle (27).
6 Tighten the locknut (38).
7 Safety the locknut (38) with the lock washer (39).
(u) Install the bolt (37) and the nut (35).
(v) Tighten the nut (35).
B. Installation of the Cargo Fire-Extinguisher Bottle
(a) Apply Polysulfide Sealant-General Purpose Interfay - (Material No.06AAC1) to the upper brackets of the fire extinguisher bottle (1).
(b) Hold the fire extinguisher bottle (1) in its correct installation position on the structure (17).
(c) Install the bolts (18), the washers (7) and the nuts (6).
(d) Tighten the nuts (6).
(e) Remove the blanking plugs from:
(g) If the discharge heads (20) are not aligned, do the steps that follow:
2 Loosen the coupling nuts (19).
3 Align the discharge heads (20) with the flexible hoses (4).
4 TORQUE the coupling nuts (19) to between 6.8 and 5.4 m.daN (50.15 and 39.82 lbf.ft )
.
5 Safety the coupling nuts (19) with the14QFB1 Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - .
(i) Connect the flexible hose (14) to the safety relief valve (16).
(j) TORQUE the nut (15) to between 1.7 and 1.5 m.daN (12.54 and 11.06 lbf.ft )
.
(k) Connect the flexible hoses (4) to the discharge heads (20).
(l) TORQUE the nuts (5) to between 4.3 and 3.9 m.daN (31.71 and 28.76 lbf.ft )
.
(m) Install the bonding straps (25) and the nuts (24) on the ground lug bolts (26) (Ref. AMM TASK 20-28-00-912-802).
(n) Tighten the nuts (24).
(o) Make sure that you are grounded with the ELECTRICALLY GROUNDED WRIST STRAP.
1 Remove the CAP-BLANKING from each electrical connector and receptacle.
2 Connect the electrical connector (2) to the pressure switch (3).
3 Remove the protective caps (21) from the cartridges (23).
4 Connect the electrical connectors (22) to the cartridges (23).
(q) Put the eye-end of the tie-rod (9) in position between the lugs on the fire extinguisher bottle (1).
(r) If necessary, adjust the tie-rod (9) as follows:
1 Loosen the locknut (11) and remove the eye-end of the tie-rod (9) from the rod-end (13).
2 Unfold the lugs of the lockwasher (12).
3 Remove and discard the lockwasher (12).
4 Install the new AIPC 26-23-02-02-100 LOCK WASHER (12) and the eye-end of the tie-rod (9) on the rod-end (13).
5 Adjust the tie-rod (9) until the bolt (10) goes through the eye-end of the tie-rod (9) and the lugs on the fire extinguisher bottle (1).
6 Tighten the locknut (11).
7 Safety the locknut (11) with the lockwasher (12).
(s) Install the bolt (10) and the nut (8).
(t) Tighten the nut (8).
(2) Install the fire extinguisher bottle (27) (4010WX) as follows:
(a) Apply Polysulfide Sealant-General Purpose Interfay - (Material No.06AAC1) to the upper brackets of the fire extinguisher bottle (27).
(b) Remove the halon filters (5010WM and 5011WM) from their brackets as follows:
1 Remove the three screws and the washers from the halon filters (Ref. AMM TASK 26-23-14-000-001).
2 Use the INSTALLATION TOOL - TIE WRAP to attach the halon filters to their brackets. This prevents the halon filters to fall.
3 Push the halon filters until the rigid pipe (30) moves away from the fire extinguisher bottle (27).
(c) Use the 98D26208003000 DEV- R-I,FIRE EXT BOTTLE A321ACF to hold the fire extinguisher bottle (27) in its correct installation position on the structure (44).
(d) Install the bolts (45), the washers (34) and the nuts (33).
(e) Tighten the nuts (33).
(f) Install the halon filters (5010WM and 5011WM) on their brackets as follows:
1 Move the halon filters until the rigid pipes (30) align with the fire extinguisher bottle (27).
2 Hold the halon filters and remove the INSTALLATION TOOL - TIE WRAP.
3 Install the three screws and the washers on the halon filters (Ref. AMM TASK 26-23-14-400-001).
(g) Remove the blanking plugs from:
(i) If the discharge heads (32) are not aligned, do the steps that follow:
2 Loosen the coupling nuts (46).
3 Align the discharge heads (32) with the rigid pipes (30).
4 TORQUE the coupling nuts (32) to between 6.8 and 5.4 m.daN (50.15 and 39.82 lbf.ft )
.
5 Safety the coupling nuts (32) with the14QFB1 Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - .
(k) Connect the flexible hose (41) to the safety relief valve (43).
(l) TORQUE the nut (42) to between 1.7 and 1.5 m.daN (12.54 and 11.06 lbf.ft )
.
(m) Connect the rigid pipes (30) to the discharge heads (32).
(n) TORQUE the nuts (31) to between 4.3 and 3.9 m.daN (31.71 and 28.76 lbf.ft )
.
(o) Install the bonding straps (51) and the nuts (50) on the ground lug bolts (52) (Ref. AMM TASK 20-28-00-912-802).
(p) Tighten the nuts (50).
(q) Make sure that you are grounded with the ELECTRICALLY GROUNDED WRIST STRAP.
1 Remove the CAP-BLANKING from each electrical connector and receptacle.
2 Connect the electrical connector (28) to the pressure switch (29).
3 Remove the SHUNT PLUG-FIRE EXTINGUISHER CARTRIDGE,HTL (47) from the cartridges (49).
4 Connect the electrical connectors (48) to the cartridges (49).
(s) Put the eye-end of the tie-rod (36) in position between the lugs on the fire extinguisher bottle (27).
(t) If necessary, adjust the tie-rod (36) as follows:
1 Loosen the locknut (38) and remove the eye-end of the tie-rod (36) from the rod-end (40).
2 Unfold the lugs of the lockwasher (12).
3 Remove and discard the lockwasher (39).
4 Install the new AIPC 26-23-02-02-100 LOCK WASHER (39) and the eye-end of the tie-rod (36) on the rod-end (40).
5 Adjust the tie-rod (36) until the bolt (37) goes through the eye-end of the tie-rod (36) and the lugs on the fire extinguisher bottle (27).
6 Tighten the locknut (38).
7 Safety the locknut (38) with the lockwasher (39).
(u) Install the bolt (37) and the nut (35).
(v) Tighten the nut (35).
Subtask 26-23-41-865-071-A ** ON A/C NOT FOR ALL WARNING:
BE VERY CAREFUL WHEN YOU MOVE A FULL FIRE EXTINGUISHER BOTTLE. A SUDDEN OR HEAVY SHOCK TO A FULL BOTTLE CAN CAUSE UNWANTED DISCHARGE AND INJURY TO PERSONS.
(1) Install the fire extinguisher bottle (4005WX) as follows: (a) Apply Polysulfide Sealant-General Purpose Interfay - (Material No.06AAC1) to the upper brackets of the fire extinguisher bottle (1).
(b) Hold the fire extinguisher bottle (1) in its correct installation position on the structure (17).
(c) Install the bolts (18), the washers (7) and the nuts (6).
(d) Tighten the nuts (6).
(e) Remove the blanking plugs from:
- The disconnected line ends
- The safety relief valve (16)
- The discharge heads (20).
(g) If the discharge heads (20) are not aligned, do the steps that follow:
WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
1 Remove and discard the lockwire. 2 Loosen the coupling nuts (19).
3 Align the discharge heads (20) with the flexible hoses (4).
4 TORQUE the coupling nuts (19) to between 6.8 and 5.4 m.daN (50.15 and 39.82 lbf.ft )
. 5 Safety the coupling nuts (19) with the
CAUTION:
APPLY A SMALL QUANTITY OF THE CORRECT GREASE TO THE MALE THREADS OF THE CONNECTIONS. THIS WILL PREVENT DAMAGE TO THE THREADS.
MAKE SURE THAT GREASE DOES NOT GO INTO THE PIPES. GREASE IN THE PIPES CAN CAUSE A MALFUNCTION OF THE SYSTEM.
(h) Apply a small quantity of Synthetic Oil base Grease-Fuel and Oxidized Environment Fluorinated - (Material No.03GEE1) to the male threads of the safety relief valve (16) and the discharge heads (20). (i) Connect the flexible hose (14) to the safety relief valve (16).
(j) TORQUE the nut (15) to between 1.7 and 1.5 m.daN (12.54 and 11.06 lbf.ft )
. (k) Connect the flexible hoses (4) to the discharge heads (20).
(l) TORQUE the nuts (5) to between 4.3 and 3.9 m.daN (31.71 and 28.76 lbf.ft )
. (m) Install the bonding straps (25) and the nuts (24) on the ground lug bolts (26) (Ref. AMM TASK 20-28-00-912-802).
(n) Tighten the nuts (24).
(o) Make sure that you are grounded with the ELECTRICALLY GROUNDED WRIST STRAP.
WARNING:
BEFORE YOU TOUCH THE POWER DEVICE CARTRIDGE, MAKE SURE THAT YOU ARE GROUNDED AND THAT YOU INSTALL A SHUNT DEVICE ON IT. USE A CAP OR PLUG AS SHUNT DEVICE (THE CAP OR PLUG WILL SHUNT THE PINS TOGETHER ON THE CARTRIDGE). DO NOT USE A FOIL SHUNT.
IF YOU TOUCH A POWER DEVICE CARTRIDGE THAT DOES NOT HAVE A SHUNT DEVICE INSTALLED, AN EXPLOSION CAN OCCUR AND CAUSE INJURIES TO YOU.
CAUTION:
MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
CAUTION:
MAKE SURE THAT THE BONDING STRAP(S) IS(ARE) CONNECTED BEFORE YOU CONNECT THE ELECTRICAL CONNECTOR(S).
(p) Connect the electrical connectors as follows: 1 Remove the CAP-BLANKING from each electrical connector and receptacle.
2 Connect the electrical connector (2) to the pressure switch (3).
3 Remove the protective caps (21) from the cartridges (23).
4 Connect the electrical connectors (22) to the cartridges (23).
(q) Put the eye-end of the tie-rod (9) in position between the lugs on the fire extinguisher bottle (1).
(r) If necessary, adjust the tie-rod (9) as follows:
1 Loosen the locknut (11) and remove the eye-end of the tie-rod (9) from the rod-end (13).
2 Unfold the lugs of the lockwasher (12).
3 Remove and discard the lockwasher (12).
4 Install the new AIPC 26-23-02-02-100 LOCK WASHER (12) and the eye-end of the tie-rod (9) on the rod-end (13).
5 Adjust the tie-rod (9) until the bolt (10) goes through the eye-end of the tie-rod (9) and the lugs on the fire extinguisher bottle (1).
6 Tighten the locknut (11).
7 Safety the locknut (11) with the lockwasher (12).
(s) Install the bolt (10) and the nut (8).
(t) Tighten the nut (8).
(2) Install the fire extinguisher bottle (27) (4010WX) as follows:
(a) Apply Polysulfide Sealant-General Purpose Interfay - (Material No.06AAC1) to the upper brackets of the fire extinguisher bottle (27).
(b) Remove the halon filters (5010WM and 5011WM) from their brackets as follows:
1 Remove the three screws and the washers from the halon filters (Ref. AMM TASK 26-23-14-000-001).
2 Use the INSTALLATION TOOL - TIE WRAP to attach the halon filters to their brackets. This prevents the halon filters to fall.
3 Push the halon filters until the rigid pipe (30) moves away from the fire extinguisher bottle (27).
(c) Use the 98D26208003000 DEV- R-I,FIRE EXT BOTTLE A321ACF to hold the fire extinguisher bottle (27) in its correct installation position on the structure (44).
(d) Install the bolts (45), the washers (34) and the nuts (33).
(e) Tighten the nuts (33).
(f) Install the halon filters (5010WM and 5011WM) on their brackets as follows:
1 Move the halon filters until the rigid pipes (30) align with the fire extinguisher bottle (27).
2 Hold the halon filters and remove the INSTALLATION TOOL - TIE WRAP.
3 Install the three screws and the washers on the halon filters (Ref. AMM TASK 26-23-14-400-001).
(g) Remove the blanking plugs from:
- The disconnected line ends
- The safety relief valve (43)
- The discharge heads (32).
(i) If the discharge heads (32) are not aligned, do the steps that follow:
WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
1 Remove and discard the lockwire. 2 Loosen the coupling nuts (46).
3 Align the discharge heads (32) with the rigid pipes (30).
4 TORQUE the coupling nuts (32) to between 6.8 and 5.4 m.daN (50.15 and 39.82 lbf.ft )
. 5 Safety the coupling nuts (32) with the
CAUTION:
APPLY A SMALL QUANTITY OF THE CORRECT GREASE TO THE MALE THREADS OF THE CONNECTIONS. THIS WILL PREVENT DAMAGE TO THE THREADS.
MAKE SURE THAT GREASE DOES NOT GO INTO THE PIPES. GREASE IN THE PIPES CAN CAUSE A MALFUNCTION OF THE SYSTEM.
(j) Apply a small quantity of Synthetic Oil base Grease-Fuel and Oxidized Environment Fluorinated - (Material No.03GEE1) to the male threads of the safety relief valve (43) and the discharge heads (32). (k) Connect the flexible hose (41) to the safety relief valve (43).
(l) TORQUE the nut (42) to between 1.7 and 1.5 m.daN (12.54 and 11.06 lbf.ft )
. (m) Connect the rigid pipes (30) to the discharge heads (32).
(n) TORQUE the nuts (31) to between 4.3 and 3.9 m.daN (31.71 and 28.76 lbf.ft )
. (o) Install the bonding straps (51) and the nuts (50) on the ground lug bolts (52) (Ref. AMM TASK 20-28-00-912-802).
(p) Tighten the nuts (50).
(q) Make sure that you are grounded with the ELECTRICALLY GROUNDED WRIST STRAP.
WARNING:
BEFORE YOU TOUCH THE POWER DEVICE CARTRIDGE, MAKE SURE THAT YOU ARE GROUNDED AND THAT YOU INSTALL A SHUNT DEVICE ON IT. USE A CAP OR PLUG AS SHUNT DEVICE (THE CAP OR PLUG WILL SHUNT THE PINS TOGETHER ON THE CARTRIDGE). DO NOT USE A FOIL SHUNT.
IF YOU TOUCH A POWER DEVICE CARTRIDGE THAT DOES NOT HAVE A SHUNT DEVICE INSTALLED, AN EXPLOSION CAN OCCUR AND CAUSE INJURIES TO YOU.
CAUTION:
MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
CAUTION:
MAKE SURE THAT THE BONDING STRAP(S) IS(ARE) CONNECTED BEFORE YOU CONNECT THE ELECTRICAL CONNECTOR(S).
(r) Connect the electrical connectors as follows: 1 Remove the CAP-BLANKING from each electrical connector and receptacle.
2 Connect the electrical connector (28) to the pressure switch (29).
3 Remove the SHUNT PLUG-FIRE EXTINGUISHER CARTRIDGE,HTL (47) from the cartridges (49).
4 Connect the electrical connectors (48) to the cartridges (49).
(s) Put the eye-end of the tie-rod (36) in position between the lugs on the fire extinguisher bottle (27).
(t) If necessary, adjust the tie-rod (36) as follows:
1 Loosen the locknut (38) and remove the eye-end of the tie-rod (36) from the rod-end (40).
2 Unfold the lugs of the lockwasher (12).
3 Remove and discard the lockwasher (39).
4 Install the new AIPC 26-23-02-02-100 LOCK WASHER (39) and the eye-end of the tie-rod (36) on the rod-end (40).
5 Adjust the tie-rod (36) until the bolt (37) goes through the eye-end of the tie-rod (36) and the lugs on the fire extinguisher bottle (27).
6 Tighten the locknut (38).
7 Safety the locknut (38) with the lockwasher (39).
(u) Install the bolt (37) and the nut (35).
(v) Tighten the nut (35).
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 26-23-41-710-056-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/CARGO FIRE/EXTIG/BTL2 | 8WX | C05 |
| 49VU | AIR COND/CARGO/FIRE/EXTIG/BTL1 | 1WX | C04 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/CARGO FIRE/EXTIG/BTL2 | 8WX | C04 |
| 49VU | AIR COND/CARGO/FIRE/EXTIG/BTL1 | 1WX | C03 |
D. Test
(1) Do the operational test of the cargo-compartment smoke-detection system (Ref. AMM TASK 26-16-00-710-001).
5. Close-up(1) Do the operational test of the cargo-compartment smoke-detection system (Ref. AMM TASK 26-16-00-710-001).
Subtask 26-23-41-410-058-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the sidewall panel 132MW (Ref. AMM TASK 25-54-12-400-003).
(3) Set the CARGO COMPT LIGHT switch 6LU to OFF.
(4) Close the forward cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-002).
Subtask 26-23-41-410-058-B ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the sidewall panel 132MW (Ref. AMM TASK 25-54-12-400-003).
(3) Set the CARGO COMPT LIGHT switch 6LU to OFF.
(4) Close the forward cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-002).
A. Close Access
(1) If an Additional Center Tank (ACT) is installed:
(a) Make sure that the work area is clean and clear of tools and other items.
(b) Install sidewall panel 132MW (Ref. AMM TASK 25-54-12-400-003).
(c) Install ceiling panel 131CC on the cargo compartment (Ref. AMM TASK 25-54-12-400-002).
(d) Install cabin floor panel 231VF (Ref. AMM TASK 53-22-12-400-001).
(2) If the ACT is not installed:
(a) Make sure that the work area is clean and clear of tools and other items.
(b) Install sidewall panel 132MW (Ref. AMM TASK 25-54-12-400-003).
(c) Set CARGO COMPT LIGHT switch 6LU to OFF.
(d) Close forward cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-002).
(e) Remove the access platform(s).
Subtask 26-23-41-862-051-A ** ON A/C NOT FOR ALL (1) If an Additional Center Tank (ACT) is installed:
(a) Make sure that the work area is clean and clear of tools and other items.
(b) Install sidewall panel 132MW (Ref. AMM TASK 25-54-12-400-003).
(c) Install ceiling panel 131CC on the cargo compartment (Ref. AMM TASK 25-54-12-400-002).
(d) Install cabin floor panel 231VF (Ref. AMM TASK 53-22-12-400-001).
(2) If the ACT is not installed:
(a) Make sure that the work area is clean and clear of tools and other items.
(b) Install sidewall panel 132MW (Ref. AMM TASK 25-54-12-400-003).
(c) Set CARGO COMPT LIGHT switch 6LU to OFF.
(d) Close forward cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-002).
(e) Remove the access platform(s).
B. Put the aircraft back to its initial configuration.
(1) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001)
(1) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001)
Cargo Fire Extinguisher Bottle