W DOC AIRBUS | AMM A320F

Remove Cargo Compartment Fire-Extinguisher for in-shop Hydrostatic Test and Check of Pressure Switch Setting


TASK 26-23-41-280-002-B
Remove Cargo Compartment Fire-Extinguisher for in-shop Hydrostatic Test and Check of Pressure Switch Setting


ZONE: 132
FIN: 4005WX ** ON A/C NOT FOR ALL
FIN: 4010WX ** ON A/C NOT FOR ALL
1. Reason for the Job
Refer to the MPD TASK: 262341-02
REMOVE CARGO COMPARTMENT FIRE EXTINGUISHER FOR IN SHOP HYDROSTATIC TEST AND CHECK OF PRESSURE SWITCH SETTING

2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
132
FORWARD CARGO COMPARTMENT
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 26-23-41-000-004-B
Removal of the Cargo Fire-Extinguisher Bottle
TASK 26-23-41-400-004-B
Installation of the Cargo Fire-Extinguisher Bottle
3. Job Set-up
Subtask 26-23-41-020-063-A ** ON A/C NOT FOR ALL
A. Removal of the Fire Extinguisher Bottle
   (1) Remove the fire extinguisher bottle (Ref. AMM TASK 26-23-41-000-004).
4. Procedure
Subtask 26-23-41-280-053-A ** ON A/C NOT FOR ALL
A. Hydrostatic Test and Check of Pressure Switch Setting
   (1) Send the fire-extinguisher bottle to the workshop for the hydrostatic test and the check of the pressure switch setting. Obey the manufacturer's instructions given in the related Component Maintenance Manual (CMM).
NOTE: To find the CMM reference, you can use the applicable P/N in the IPC. You can use the FIN in the task title to find the applicable P/N.
5. Close-up
Subtask 26-23-41-420-062-A ** ON A/C NOT FOR ALL
A. Installation of the Fire Extinguisher Bottle
   (1) Install a serviceable fire extinguisher bottle (Ref. AMM TASK 26-23-41-400-004).
[Rev.8 from Aug 2017] 2026.03.31 23:46:39 UTC