Remove Cargo Compartment Fire-Extinguisher for in-shop Hydrostatic Test and Check of Pressure Switch Setting
TASK 26-23-41-280-002-A
Remove Cargo Compartment Fire-Extinguisher for in-shop Hydrostatic Test and Check of Pressure Switch Setting
Refer to the MPD TASK: 262341-02
REMOVE CARGO COMPARTMENT FIRE EXTINGUISHER FOR IN SHOP HYDROSTATIC TEST AND CHECK OF PRESSURE SWITCH SETTING
2. Job Set-up Information
A. Work Zones and Access Panels
B. Referenced Information
3. Job Set-up
Subtask 26-23-41-020-053-A
Subtask 26-23-41-280-051-A
Subtask 26-23-41-420-052-A
[Rev.10 from 2021]
2026.03.31 23:46:38 UTC
Remove Cargo Compartment Fire-Extinguisher for in-shop Hydrostatic Test and Check of Pressure Switch Setting
ZONE: 132
1. Reason for the JobRefer to the MPD TASK: 262341-02
REMOVE CARGO COMPARTMENT FIRE EXTINGUISHER FOR IN SHOP HYDROSTATIC TEST AND CHECK OF PRESSURE SWITCH SETTING
2. Job Set-up Information
A. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 132 | FORWARD CARGO COMPARTMENT |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 26-23-41-000-004-A | Removal of the Cargo Fire-Extinguisher Bottle |
| TASK 26-23-41-000-004-B | Removal of the Cargo Fire-Extinguisher Bottle |
| TASK 26-23-41-400-004-A | Installation of the Cargo Fire-Extinguisher Bottle |
| TASK 26-23-41-400-004-B | Installation of the Cargo Fire-Extinguisher Bottle |
| TASK 26-23-42-000-001-A | Removal of the Cargo Fire-Extinguisher Bottle |
| TASK 26-23-42-400-001-A | Installation of the Cargo Fire-Extinguisher Bottle |
Subtask 26-23-41-020-053-A
A. Removal of the Fire Extinguisher Bottle
(1) Remove the fire extinguisher bottle (Ref. AMM TASK 26-23-41-000-004) or (Ref. AMM TASK 26-23-42-000-001).
4. Procedure(1) Remove the fire extinguisher bottle (Ref. AMM TASK 26-23-41-000-004) or (Ref. AMM TASK 26-23-42-000-001).
Subtask 26-23-41-280-051-A
A. Hydrostatic Test and Check of Pressure Switch Setting
(1) Send the fire-extinguisher bottle to the workshop.
5. Close-up(1) Send the fire-extinguisher bottle to the workshop.
Subtask 26-23-41-420-052-A
A. Installation of the Fire Extinguisher Bottle
(1) Install a serviceable fire extinguisher bottle (Ref. AMM TASK 26-23-41-400-004) or (Ref. AMM TASK 26-23-42-400-001).