W DOC AIRBUS | AMM A320F

Removal of the Cargo Fire-Extinguisher Bottle


TASK 26-23-41-000-004-B
Removal of the Cargo Fire-Extinguisher Bottle


WARNING: BE CAREFUL WHEN YOU REMOVE OR INSTALL THIS EQUIPMENT. THIS EQUIPMENT IS HEAVY (MORE THAN 12 KG (26.5 lb)) AND CAN CAUSE INJURY AND/OR DAMAGE.
WARNING: IF YOU REMOVE THE FIRE EXTINGUISHER BOTTLES IN A CLOSED HANGAR, MAKE SURE THAT THERE IS A FLOW OF NEW AIR IN THE HANGAR.
CAUTION: BEFORE YOU INSTALL/REMOVE THE GSE-TOOL, READ THE INSTRUCTIONS IN THE APPLICABLE GSE INSTRUCTION MANUAL. WHILE YOU OPERATE THIS TOOL, CAREFULLY OBEY THEM. IF YOU DO NOT OBEY THE INSTRUCTIONS, DAMAGE TO EQUIPMENT CAN OCCUR.
ZONE: 130
FIN: 4005WX ** ON A/C NOT FOR ALL
FIN: 4010WX ** ON A/C NOT FOR ALL
1. Reason for the Job
NOTE: Two persons are necessary to do this task.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT)
No specific
AR
CAP - BLANKING
No specific
AR
ELECTRICALLY GROUNDED WRIST STRAP
No specific
AR
INSTALLATION TOOL - TIE WRAP
No specific
AR
PLUG - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
10-101950-81
2
SHUNT PLUG-FIRE EXTINGUISHER CARTRIDGE,HTL
2-100831-1
AR
PLUG-SHUNT
98D26208003000
1
DEV- R-I,FIRE EXT BOTTLE A321ACF
M83723-60-110AN
AR
PROTECTIVE CAP-FIRE EXTINGUISHER CARTRIDGE
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
130
FWD CARGO COMPT AFT BULKHEAD OF AVNCS COMPT TO FWD PRESSURE BULKHEAD OF WING CENTER BOX
131CC, 231VF
132MW, 825
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 25-54-12-000-002-A
Removal of the Ceiling Panels in the Forward Cargo Compartment
TASK 25-54-12-000-003-A
Removal of the Sidewall Panels in the Forward Cargo Compartment
TASK 26-23-14-000-001-A
Removal of the Halon Filter
TASK 52-30-00-860-001-A
Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
TASK 53-22-12-000-001-A
Removal of the Cabin Floor Panels
TASK 26-23-00-00
CARGO COMPARTMENT FIRE EXTINGUISHING - DESCRIPTION AND OPERATION
F Cargo Fire Extinguisher Bottle ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 26-23-41-861-052-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 26-23-41-865-069-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR COND/CARGO FIRE/EXTIG/BTL28WXC05
49VUAIR COND/CARGO/FIRE/EXTIG/BTL11WXC04
** ON A/C NOT FOR ALL
49VUAIR COND/CARGO FIRE/EXTIG/BTL28WXC04
49VUAIR COND/CARGO/FIRE/EXTIG/BTL11WXC03
Subtask 26-23-41-010-059-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) For the location of this component, refer to Para. Component Location (Ref. AMM D/O 26-23-00-00).
   (2) Open the forward cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-001).
   (3) Set the CARGO COMPT LIGHT switch 6LU to the ON position.
   (4) Remove the sidewall panel 132MW (Ref. AMM TASK 25-54-12-000-003).
Subtask 26-23-41-010-059-C ** ON A/C NOT FOR ALL
C. Get Access
   (1) For the location of this component, refer to (Ref. AMM D/O 26-23-00-00).
   (2) If an Additional Center Tank (ACT) is installed:
     (a) Remove cabin floor panel 231VF (Ref. AMM TASK 53-22-12-000-001).
     (b) Remove ceiling panel 131CC from the cargo compartment (Ref. AMM TASK 25-54-12-000-002).
     (c) Remove sidewall panel 132MW (Ref. AMM TASK 25-54-12-000-003).
   (3) If the ACT is not installed:
     (a) Put an ACCESS PLATFORM 2M (6 FT) in position at zone 825.
     (b) Open forward cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-001).
     (c) Set CARGO COMPT LIGHT switch 6LU to ON.
     (d) Remove sidewall panel 132MW (Ref. AMM TASK 25-54-12-000-003).
4. Procedure
Subtask 26-23-41-020-061-B
A. Removal of the Cargo Fire-Extinguisher Bottle
   (1) Remove the fire extinguisher bottle (4005WX) as follows:
     (a) Make sure that you are grounded with the ELECTRICALLY GROUNDED WRIST STRAP.
CAUTION: MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
     (b) Disconnect the electrical connectors (22) as follows:
WARNING: BEFORE YOU TOUCH THE POWER DEVICE CARTRIDGE, MAKE SURE THAT YOU ARE GROUNDED AND THAT YOU INSTALL A SHUNT DEVICE ON IT. USE A CAP OR PLUG AS SHUNT DEVICE (THE CAP OR PLUG WILL SHUNT THE PINS TOGETHER ON THE CARTRIDGE). DO NOT USE A FOIL SHUNT. IF YOU TOUCH A POWER DEVICE CARTRIDGE THAT DOES NOT HAVE A SHUNT DEVICE INSTALLED, AN EXPLOSION CAN OCCUR AND CAUSE INJURIES TO YOU.
       1 Disconnect the electrical connectors (22) from the cartridges (23).
       2 Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
       3 Put the 2-100831-1 PLUG-SHUNT (21) on the cartridges (23).
NOTE: The M83723-60-110AN PROTECTIVE CAP-FIRE EXTINGUISHER CARTRIDGE can be used as an alternative to the 2-100831-1 PLUG-SHUNT.
CAUTION: MAKE SURE THAT THE ELECTRICAL CONNECTOR(S) IS(ARE) DISCONNECTED BEFORE YOU DISCONNECT THE BONDING STRAP(S).
     (c) Remove the nuts (24) and the bonding straps (25) from the ground lug bolts (26).
CAUTION: MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
     (d) Disconnect the electrical connector (2) from the pressure switch (3).
     (e) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
     (f) Loosen the nuts (5) and disconnect the flexible hoses (4) from the discharge heads (20):
       1 Do not remove the safety beaded chain that is installed on the flexible hoses (4). This prevents the cross-connection of the cartridge electrical connectors.
     (g) Put the PLUG - BLANKING on the disconnected line ends and the discharge heads (20).
     (h) Loosen the nut (15) and disconnect the flexible hose (14) from the safety relief valve (16).
     (i) Put the PLUG - BLANKING on the disconnected line end and the safety relief valve (16).
     (j) Remove the nut (8) and the bolt (10) and then move the tie-rod (9) away from the fire extinguisher bottle (1).
     (k) Remove the fire extinguisher bottle (1) as follows:
WARNING: BE VERY CAREFUL WHEN YOU MOVE A FULL FIRE EXTINGUISHER BOTTLE. A SUDDEN OR HEAVY SHOCK TO A FULL BOTTLE CAN CAUSE UNWANTED DISCHARGE AND INJURY TO PERSONS.
       1 Hold the fire extinguisher bottle (1) and remove the nuts (6), the washers (7) and the bolts (18).
       2 Remove the fire extinguisher bottle (1) and put it on an applicable support.
   (2) Remove the fire extinguisher bottle (4010WX) as follows:
     (a) Make sure that you are grounded with the ELECTRICALLY GROUNDED WRIST STRAP.
CAUTION: MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
     (b) Disconnect the electrical connectors (48) as follows:
WARNING: BEFORE YOU TOUCH THE POWER DEVICE CARTRIDGE, MAKE SURE THAT YOU ARE GROUNDED AND THAT YOU INSTALL A SHUNT DEVICE ON IT. USE A CAP OR PLUG AS SHUNT DEVICE (THE CAP OR PLUG WILL SHUNT THE PINS TOGETHER ON THE CARTRIDGE). DO NOT USE A FOIL SHUNT. IF YOU TOUCH A POWER DEVICE CARTRIDGE THAT DOES NOT HAVE A SHUNT DEVICE INSTALLED, AN EXPLOSION CAN OCCUR AND CAUSE INJURIES TO YOU.
       1 Disconnect the electrical connectors (48) from the cartridges (49).
       2 Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
       3 Put the 2-100831-1 PLUG-SHUNT (47) on the cartridges (49).
NOTE: The M83723-60-110AN PROTECTIVE CAP-FIRE EXTINGUISHER CARTRIDGE can be used as an alternative to the 2-100831-1 PLUG-SHUNT.
CAUTION: MAKE SURE THAT THE ELECTRICAL CONNECTOR(S) IS(ARE) DISCONNECTED BEFORE YOU DISCONNECT THE BONDING STRAP(S).
     (c) Remove the nuts (50) and the bonding straps (51) from the ground lug bolts (52).
CAUTION: MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
     (d) Disconnect the electrical connector (28) from the pressure switch (29).
     (e) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
     (f) Loosen the nuts (31) and disconnect the rigid pipe (30) from the discharge heads (32):
       1 Do not remove the safety beaded chain that is installed on the rigid pipe (30). This prevents the cross-connection of the cartridge electrical connectors.
     (g) Remove the halon filters (5010WM and 5011WM) from their brackets as follows:
       1 Remove the three screws and the washers from the halon filters (Ref. AMM TASK 26-23-14-000-001).
       2 Use the INSTALLATION TOOL - TIE WRAP to attach the halon filters to their brackets. This prevents the halon filters to fall.
       3 Push the halon filters until the rigid pipe (30) moves away from the fire extinguisher bottle (27).
     (h) Put the PLUG - BLANKING on the disconnected line ends and the discharge heads (32).
     (i) Loosen the nut (42) and disconnect the flexible hose (41) from the safety relief valve (43).
     (j) Put the PLUG - BLANKING on the disconnected line end and the safety relief valve (43).
     (k) Remove the nut (35) and the bolt (37) and then move the tie-rod (36) away from the fire extinguisher bottle (27).
     (l) Remove the fire extinguisher bottle (27) as follows:
WARNING: BE VERY CAREFUL WHEN YOU MOVE A FULL FIRE EXTINGUISHER BOTTLE. A SUDDEN OR HEAVY SHOCK TO A FULL BOTTLE CAN CAUSE UNWANTED DISCHARGE AND INJURY TO PERSONS.
       1 Hold the fire extinguisher bottle (27) and remove the nuts (33), the washers (34) and the bolts (45).
       2 Remove the fire extinguisher bottle (27) and put it on an applicable support.
Subtask 26-23-41-020-061-C ** ON A/C NOT FOR ALL
A. Removal of the Cargo Fire-Extinguisher Bottle
   (1) Remove the fire extinguisher bottle (4005WX) as follows:
     (a) Make sure that you are grounded with the ELECTRICALLY GROUNDED WRIST STRAP.
CAUTION: MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
     (b) Disconnect the electrical connectors (22) as follows:
WARNING: BEFORE YOU TOUCH THE POWER DEVICE CARTRIDGE, MAKE SURE THAT YOU ARE GROUNDED AND THAT YOU INSTALL A SHUNT DEVICE ON IT. USE A CAP OR PLUG AS SHUNT DEVICE (THE CAP OR PLUG WILL SHUNT THE PINS TOGETHER ON THE CARTRIDGE). DO NOT USE A FOIL SHUNT. IF YOU TOUCH A POWER DEVICE CARTRIDGE THAT DOES NOT HAVE A SHUNT DEVICE INSTALLED, AN EXPLOSION CAN OCCUR AND CAUSE INJURIES TO YOU.
       1 Disconnect the electrical connectors (22) from the cartridges (23).
       2 Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
       3 Put the 2-100831-1 PLUG-SHUNT (21) on the cartridges (23).
NOTE: The M83723-60-110AN PROTECTIVE CAP-FIRE EXTINGUISHER CARTRIDGE can be used as an alternative to the 2-100831-1 PLUG-SHUNT.
CAUTION: MAKE SURE THAT THE ELECTRICAL CONNECTOR(S) IS(ARE) DISCONNECTED BEFORE YOU DISCONNECT THE BONDING STRAP(S).
     (c) Remove the nuts (24) and the bonding straps (25) from the ground lug bolts (26).
CAUTION: MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
     (d) Disconnect the electrical connector (2) from the pressure switch (3).
     (e) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
     (f) Loosen the nuts (5) and disconnect the flexible hoses (4) from the discharge heads (20):
       1 Do not remove the safety beaded chain that is installed on the flexible hoses (4). This prevents the cross-connection of the cartridge electrical connectors.
     (g) Put the PLUG - BLANKING on the disconnected line ends and the discharge heads (20).
     (h) Loosen the nut (15) and disconnect the flexible hose (14) from the safety relief valve (16).
     (i) Put the PLUG - BLANKING on the disconnected line end and the safety relief valve (16).
     (j) Remove the nut (8) and the bolt (10) and then move the tie-rod (9) away from the fire extinguisher bottle (1).
     (k) Remove the fire extinguisher bottle (1) as follows:
WARNING: BE VERY CAREFUL WHEN YOU MOVE A FULL FIRE EXTINGUISHER BOTTLE. A SUDDEN OR HEAVY SHOCK TO A FULL BOTTLE CAN CAUSE UNWANTED DISCHARGE AND INJURY TO PERSONS.
       1 Hold the fire extinguisher bottle (1) and remove the nuts (6), the washers (7) and the bolts (18).
       2 Remove the fire extinguisher bottle (1) and put it on an applicable support.
   (2) Remove the fire extinguisher bottle (4010WX) as follows:
     (a) Make sure that you are grounded with the ELECTRICALLY GROUNDED WRIST STRAP.
CAUTION: MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
     (b) Disconnect the electrical connectors (48) as follows:
WARNING: BEFORE YOU TOUCH THE POWER DEVICE CARTRIDGE, MAKE SURE THAT YOU ARE GROUNDED AND THAT YOU INSTALL A SHUNT DEVICE ON IT. USE A CAP OR PLUG AS SHUNT DEVICE (THE CAP OR PLUG WILL SHUNT THE PINS TOGETHER ON THE CARTRIDGE). DO NOT USE A FOIL SHUNT. IF YOU TOUCH A POWER DEVICE CARTRIDGE THAT DOES NOT HAVE A SHUNT DEVICE INSTALLED, AN EXPLOSION CAN OCCUR AND CAUSE INJURIES TO YOU.
       1 Disconnect the electrical connectors (48) from the cartridges (49).
       2 Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
       3 Put the 10-101950-81 SHUNT PLUG-FIRE EXTINGUISHER CARTRIDGE,HTL (47) on the cartridges (49).
CAUTION: MAKE SURE THAT THE ELECTRICAL CONNECTOR(S) IS(ARE) DISCONNECTED BEFORE YOU DISCONNECT THE BONDING STRAP(S).
     (c) Remove the nuts (50) and the bonding straps (51) from the ground lug bolts (52).
CAUTION: MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
     (d) Disconnect the electrical connector (28) from the pressure switch (29).
     (e) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
     (f) Loosen the nuts (31) and disconnect the rigid pipe (30) from the discharge heads (32):
       1 Do not remove the safety beaded chain that is installed on the rigid pipe (30). This prevents the cross-connection of the cartridge electrical connectors.
     (g) Remove the halon filters (5010WM and 5011WM) from their brackets as follows:
       1 Remove the three screws and the washers from the halon filters (Ref. AMM TASK 26-23-14-000-001).
       2 Use the INSTALLATION TOOL - TIE WRAP to attach the halon filters to their brackets. This prevents the halon filters to fall.
       3 Push the halon filters until the rigid pipe (30) moves away from the fire extinguisher bottle (27).
     (h) Put the PLUG - BLANKING on the disconnected line ends and the discharge heads (32).
     (i) Loosen the nut (42) and disconnect the flexible hose (41) from the safety relief valve (43).
     (j) Put the PLUG - BLANKING on the disconnected line end and the safety relief valve (43).
     (k) Remove the nut (35) and the bolt (37) and then move the tie-rod (36) away from the fire extinguisher bottle (27).
     (l) Remove the fire extinguisher bottle (27) as follows:
WARNING: BE VERY CAREFUL WHEN YOU MOVE A FULL FIRE EXTINGUISHER BOTTLE. A SUDDEN OR HEAVY SHOCK TO A FULL BOTTLE CAN CAUSE UNWANTED DISCHARGE AND INJURY TO PERSONS.
       1 Hold the fire extinguisher bottle (27) and remove the nuts (33), the washers (34) and the bolts (45).
       2 Remove the fire extinguisher bottle (27) and put it on an applicable support.
Subtask 26-23-41-020-061-F ** ON A/C NOT FOR ALL
A. Removal of the Cargo Fire-Extinguisher Bottle
   (1) Remove the fire extinguisher bottle (4005WX) as follows:
     (a) Make sure that you are grounded with the ELECTRICALLY GROUNDED WRIST STRAP.
CAUTION: MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
     (b) Disconnect the electrical connectors (22) as follows:
WARNING: BEFORE YOU TOUCH THE POWER DEVICE CARTRIDGE, MAKE SURE THAT YOU ARE GROUNDED AND THAT YOU INSTALL A SHUNT DEVICE ON IT. USE A CAP OR PLUG AS SHUNT DEVICE (THE CAP OR PLUG WILL SHUNT THE PINS TOGETHER ON THE CARTRIDGE). DO NOT USE A FOIL SHUNT. IF YOU TOUCH A POWER DEVICE CARTRIDGE THAT DOES NOT HAVE A SHUNT DEVICE INSTALLED, AN EXPLOSION CAN OCCUR AND CAUSE INJURIES TO YOU.
       1 Disconnect the electrical connectors (22) from the cartridges (23).
       2 Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
       3 Put the 2-100831-1 PLUG-SHUNT (21) on the cartridges (23).
NOTE: The M83723-60-110AN PROTECTIVE CAP-FIRE EXTINGUISHER CARTRIDGE can be used as an alternative to the 2-100831-1 PLUG-SHUNT.
CAUTION: MAKE SURE THAT THE ELECTRICAL CONNECTOR(S) IS(ARE) DISCONNECTED BEFORE YOU DISCONNECT THE BONDING STRAP(S).
     (c) Remove the nuts (24) and the bonding straps (25) from the ground lug bolts (26).
CAUTION: MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
     (d) Disconnect the electrical connector (2) from the pressure switch (3).
     (e) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
     (f) Loosen the nuts (5) and disconnect the flexible hoses (4) from the discharge heads (20):
       1 Do not remove the safety beaded chain that is installed on the flexible hoses (4). This prevents the cross-connection of the cartridge electrical connectors.
     (g) Put the PLUG - BLANKING on the disconnected line ends and the discharge heads (20).
     (h) Loosen the nut (15) and disconnect the flexible hose (14) from the safety relief valve (16).
     (i) Put the PLUG - BLANKING on the disconnected line end and the safety relief valve (16).
     (j) Remove the nut (8) and the bolt (10) and then move the tie-rod (9) away from the fire extinguisher bottle (1).
     (k) Remove the fire extinguisher bottle (1) as follows:
WARNING: BE VERY CAREFUL WHEN YOU MOVE A FULL FIRE EXTINGUISHER BOTTLE. A SUDDEN OR HEAVY SHOCK TO A FULL BOTTLE CAN CAUSE UNWANTED DISCHARGE AND INJURY TO PERSONS.
       1 Hold the fire extinguisher bottle (1) and remove the nuts (6), the washers (7) and the bolts (18).
       2 Remove the fire extinguisher bottle (1) and put it on an applicable support.
   (2) Remove the fire extinguisher bottle (4010WX) as follows:
     (a) Make sure that you are grounded with the ELECTRICALLY GROUNDED WRIST STRAP.
CAUTION: MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
     (b) Disconnect the electrical connectors (48) as follows:
WARNING: BEFORE YOU TOUCH THE POWER DEVICE CARTRIDGE, MAKE SURE THAT YOU ARE GROUNDED AND THAT YOU INSTALL A SHUNT DEVICE ON IT. USE A CAP OR PLUG AS SHUNT DEVICE (THE CAP OR PLUG WILL SHUNT THE PINS TOGETHER ON THE CARTRIDGE). DO NOT USE A FOIL SHUNT. IF YOU TOUCH A POWER DEVICE CARTRIDGE THAT DOES NOT HAVE A SHUNT DEVICE INSTALLED, AN EXPLOSION CAN OCCUR AND CAUSE INJURIES TO YOU.
       1 Disconnect the electrical connectors (48) from the cartridges (49).
       2 Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
       3 Put the 10-101950-81 SHUNT PLUG-FIRE EXTINGUISHER CARTRIDGE,HTL (47) on the cartridges (49).
CAUTION: MAKE SURE THAT THE ELECTRICAL CONNECTOR(S) IS(ARE) DISCONNECTED BEFORE YOU DISCONNECT THE BONDING STRAP(S).
     (c) Remove the nuts (50) and the bonding straps (51) from the ground lug bolts (52).
CAUTION: MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
     (d) Disconnect the electrical connector (28) from the pressure switch (29).
     (e) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
     (f) Loosen the nuts (31) and disconnect the rigid pipe (30) from the discharge heads (32):
       1 Do not remove the safety beaded chain that is installed on the rigid pipe (30). This prevents the cross-connection of the cartridge electrical connectors.
     (g) Remove the halon filters (5010WM and 5011WM) from their brackets as follows:
       1 Remove the three screws and the washers from the halon filters (Ref. AMM TASK 26-23-14-000-001).
       2 Use the INSTALLATION TOOL - TIE WRAP to attach the halon filters to their brackets. This prevents the halon filters to fall.
       3 Push the halon filters until the rigid pipe (30) moves away from the fire extinguisher bottle (27).
     (h) Put the PLUG - BLANKING on the disconnected line ends and the discharge heads (32).
     (i) Loosen the nut (42) and disconnect the flexible hose (41) from the safety relief valve (43).
     (j) Put the PLUG - BLANKING on the disconnected line end and the safety relief valve (43).
     (k) Remove the nut (35) and the bolt (37) and move the tie-rod (36) away from the fire extinguisher bottle (27).
     (l) Remove the fire extinguisher bottle (27):
WARNING: BE VERY CAREFUL WHEN YOU MOVE A FULL FIRE EXTINGUISHER BOTTLE. A SUDDEN OR HEAVY SHOCK TO A FULL BOTTLE CAN CAUSE UNWANTED DISCHARGE AND INJURY TO PERSONS.
       1 Use the 98D26208003000 DEV- R-I,FIRE EXT BOTTLE A321ACF to hold the fire extinguisher bottle (27).
       2 Remove the nuts (33), the washers (34) and the bolts (45).
       3 Remove the fire extinguisher bottle (27) and put it on the applicable support of the 98D26208003000 DEV- R-I,FIRE EXT BOTTLE A321ACF.