Check Firing Circuit Continuity
TASK 26-22-00-720-001-A
Check Firing Circuit Continuity
Refer to the MPD TASK: 262200-03
CHECK FIRING CIRCUIT CONTINUITY
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 26-22-00-861-056-A
Subtask 26-22-00-720-050-A
Subtask 26-22-00-865-121-A
[Rev.10 from 2021]
2026.03.31 23:45:31 UTC
Check Firing Circuit Continuity
WARNING:
BE VERY CAREFUL WHEN YOU MOVE A FULL FIRE EXTINGUISHER BOTTLE. A SUDDEN OR HEAVY SHOCK TO A FULL BOTTLE CAN CAUSE UNWANTED DISCHARGE AND INJURY TO PERSONS.
WARNING:
CAREFULLY OBEY THE APPROVED PROCEDURE FOR THIS TASK. TO PREVENT THE EXPLOSION OF THE CARTRIDGE, MAKE SURE THAT YOU INSTALL AN ELECTROSTATIC PROTECTIVE CAP ON THE DISCHARGE CARTRIDGE WHEN YOU DO THIS TASK.
ZONE: 210
1. Reason for the JobRefer to the MPD TASK: 262200-03
CHECK FIRING CIRCUIT CONTINUITY
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE |
| No specific | 1 | FLASHLIGHT |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | 1 | VOLTMETER - DC |
| 6971-0010 | 1 | CAP SHUNT-FIRE BOTTLE |
| MS25043-10DA | 1 | CARTRIDGE CAP |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| 314AR |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 26-22-00-710-001-A | Operational Test of the APU Fire-Extinguishing Loop/Squib |
| TASK 52-41-23-010-801-A | Opening of Access Door 314AR |
| TASK 52-41-23-410-801-A | Closing of Access Door 314AR |
Subtask 26-22-00-861-056-A
A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002) or (Ref. AMM TASK 24-41-00-861-002).
Subtask 26-22-00-865-060-A (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002) or (Ref. AMM TASK 24-41-00-861-002).
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 26-22-00-010-052-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | APU/APU/CTL | 2KD | L42 |
| 121VU | APU/ECB/SPLY | 1KD | L41 |
| 121VU | APU/FIRE/EXTIG/SQUIB/B | 2WF | L39 |
| 121VU | APU/FIRE/EXTIG/SQUIB/A | 1WF | L38 |
C. Get Access
(2) Put an ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position below access door 314AR.
(3) Open access door 314AR and safety it in the open position.
(Ref. AMM TASK 52-41-23-010-801).
(4) If necessary, use a FLASHLIGHT.
(5) Disconnect electrical connector 12WF-A (2) from cartridge 12WF (1).
(6) Put a MS25043-10DA CARTRIDGE CAP (3) on cartridge 12WF (1).
Subtask 26-22-00-010-052-B ** ON A/C NOT FOR ALL WARNING:
BEFORE YOU START WORK, YOU MUST PUT ON A SAFETY HARNESS AND ATTACH IT TO THE ACCESS PLATFORM. WITHOUT A SAFETY HARNESS, YOU CAN FALL. THIS CAN KILL YOU OR CAUSE YOU INJURY.
(1) Put on and attach a safety harness before you start work in the work area(2) Put an ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position below access door 314AR.
(3) Open access door 314AR and safety it in the open position.
(Ref. AMM TASK 52-41-23-010-801).
(4) If necessary, use a FLASHLIGHT.
(5) Disconnect electrical connector 12WF-A (2) from cartridge 12WF (1).
(6) Put a MS25043-10DA CARTRIDGE CAP (3) on cartridge 12WF (1).
C. Get Access
(2) Put an ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in posotion below access door 314AR.
(3) Open access door 314AR and safety it in the open position.
(Ref. AMM TASK 52-41-23-010-801).
(4) If necessary, use a FLASHLIGHT.
(5) Disconnect electrical connector 12WF-A (2) from cartridge 12WF (1).
(6) Put a 6971-0010 CAP SHUNT-FIRE BOTTLE (3) on cartridge 12WF (1).
Subtask 26-22-00-865-120-A WARNING:
BEFORE YOU START WORK, YOU MUST PUT ON A SAFETY HARNESS AND ATTACH IT TO THE ACCESS PLATFORM. WITHOUT A SAFETY HARNESS, YOU CAN FALL. THIS CAN KILL YOU OR CAUSE YOU INJURY.
(1) Put on and attach a safety harness before you start work in the work area(2) Put an ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in posotion below access door 314AR.
(3) Open access door 314AR and safety it in the open position.
(Ref. AMM TASK 52-41-23-010-801).
(4) If necessary, use a FLASHLIGHT.
(5) Disconnect electrical connector 12WF-A (2) from cartridge 12WF (1).
(6) Put a 6971-0010 CAP SHUNT-FIRE BOTTLE (3) on cartridge 12WF (1).
D. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | APU/FIRE/EXTIG/SQUIB/B | 2WF | L39 |
| 121VU | APU/FIRE/EXTIG/SQUIB/A | 1WF | L38 |
Subtask 26-22-00-720-050-A
A. Test
5. Close-up| ACTION | RESULT |
|---|---|
1.At electrical connector 12WF-A (2):
| At electrical connector 12WF-A (2):
|
2.At electrical connector 12WF-A (2):
| At electrical connector 12WF-A (2):
|
3.On APU FIRE panel 20VU:
| On APU FIRE panel 20VU:
|
4.At electrical connector 12WF-A (2):
| At electrical connector 12WF-A (2):
|
5.At electrical connector 12WF-A (2):
| At electrical connector 12WF-A (2):
|
6.On APU FIRE panel 20VU:
| On APU FIRE panel 20VU:
|
7.At electrical connector 12WF-A (2):
| At electrical connector 12WF-A (2):
|
8.At electrical connector 12WF-A (2):
| At electrical connector 12WF-A (2):
|
9.On APU FIRE panel 20VU:
| On APU FIRE panel 20VU:
|
10.At electrical connector 12WF-A (2):
| At electrical connector 12WF-A (2)
|
11.At electrical connector 12WF-A (2):
| At electrical connector 12WF-A (2):
|
12.On APU FIRE panel 20VU:
| On APU FIRE panel 20VU:
|
Subtask 26-22-00-865-121-A
A. Open, safety and tag this(these) circuit breaker(s):
Subtask 26-22-00-410-053-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | APU/FIRE/EXTIG/SQUIB/B | 2WF | L39 |
| 121VU | APU/FIRE/EXTIG/SQUIB/A | 1WF | L38 |
B. Close Access
(1) Remove the MS25043-10DA CARTRIDGE CAP (3) from cartridge 12WF (1).
(2) Make sure that all the electrical connections are clean and in the correct condition.
(3) Connect electrical connector 12WF-A (2) to cartridge 12WF (1).
(4) Make sure that the work area is clean and clear of tools and other items.
(5) Close access door 314AR (Ref. AMM TASK 52-41-23-410-801).
(6) Remove the access platform(s).
Subtask 26-22-00-410-053-B ** ON A/C NOT FOR ALL (1) Remove the MS25043-10DA CARTRIDGE CAP (3) from cartridge 12WF (1).
(2) Make sure that all the electrical connections are clean and in the correct condition.
(3) Connect electrical connector 12WF-A (2) to cartridge 12WF (1).
(4) Make sure that the work area is clean and clear of tools and other items.
(5) Close access door 314AR (Ref. AMM TASK 52-41-23-410-801).
(6) Remove the access platform(s).
B. Close Access
(1) Remove the 6971-0010 CAP SHUNT-FIRE BOTTLE (3) from cartridge 12WF (1).
(2) Make sure that all the electrical connections are clean and in the correct condition.
(3) Connect electrical connector 12WF-A (2) to cartridge 12WF (1).
(4) Make sure that the work area is clean and clear of tools and other items.
(5) Close access door 314AR (Ref. AMM TASK 52-41-23-410-801).
(6) Remove the access platform(s).
Subtask 26-22-00-865-061-A (1) Remove the 6971-0010 CAP SHUNT-FIRE BOTTLE (3) from cartridge 12WF (1).
(2) Make sure that all the electrical connections are clean and in the correct condition.
(3) Connect electrical connector 12WF-A (2) to cartridge 12WF (1).
(4) Make sure that the work area is clean and clear of tools and other items.
(5) Close access door 314AR (Ref. AMM TASK 52-41-23-410-801).
(6) Remove the access platform(s).
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 26-22-00-710-090-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | APU/APU/CTL | 2KD | L42 |
| 121VU | APU/ECB/SPLY | 1KD | L41 |
| 121VU | APU/FIRE/EXTIG/SQUIB/B | 2WF | L39 |
| 121VU | APU/FIRE/EXTIG/SQUIB/A | 1WF | L38 |
D. Operational Test
(1) Do the operational test of the APU Fire-Extinguishing Loop/Squib (Ref. AMM TASK 26-22-00-710-001)
Subtask 26-22-00-862-054-A (1) Do the operational test of the APU Fire-Extinguishing Loop/Squib (Ref. AMM TASK 26-22-00-710-001)
E. Put the aircraft back to its initial configuration.
(1) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002) or (Ref. AMM TASK 24-41-00-862-002).
(1) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002) or (Ref. AMM TASK 24-41-00-862-002).
APU Fire-Extinguisher Bottle