W DOC AIRBUS | AMM A320F

Operational Check of Automatic Fire Extinguishing Circuit and Test APU LP Fuel Valve Operation using each Individual Motor in Turn and Test APU Emergency...


TASK 26-22-00-710-002-A
Operational Check of Automatic Fire Extinguishing Circuit and Test APU LP Fuel Valve Operation using each Individual Motor in Turn and Test APU Emergency...


WARNING: BE VERY CAREFUL WHEN YOU MOVE A FULL FIRE EXTINGUISHER BOTTLE. A SUDDEN OR HEAVY SHOCK TO A FULL BOTTLE CAN CAUSE UNWANTED DISCHARGE AND INJURY TO PERSONS.
ZONE: 210
1. Reason for the Job
Refer to the MPD TASK: 262200-02
OPERATIONAL CHECK OF AUTOMATIC FIRE EXTINGUISHING CIRCUIT AND TEST APU LP FUEL VALVE OPERATION USING EACH INDIVIDUAL MOTOR IN TURN AND TEST APU EMERGENCY SHUTDOWN CIRCUIT
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 31-60-00-860-001-A
EIS Start Procedure
TASK 31-60-00-860-002-A
EIS Stop Procedure
3. Job Set-up
Subtask 26-22-00-860-052-A
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002) or (Ref. AMM TASK 24-41-00-861-002).
   (2) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
Subtask 26-22-00-865-070-A
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUAPU/FUEL/PUMP/CTL3QCM38
Subtask 26-22-00-865-054-A
C. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUAPU/FIRE AND OVHT/DET/LOOP B2WGL44
121VUAPU/FIRE AND OVHT/DET/LOOP A1WGL43
121VUAPU/APU/CTL2KDL42
121VUAPU/ECB/SPLY1KDL41
121VUAPU/AUTO/EXTIG/GND/TEST30WFL40
121VUAPU/FIRE/EXTIG/SQUIB/B2WFL39
121VUAPU/FIRE/EXTIG/SQUIB/A1WFL38
121VUAPU/FIRE/LP VALVE/NORM4WFM42
121VUAPU/FIRE/LP VALVE/STBY3WFM41
121VUAPU/FUEL/LP VALVE/CTL1QFM40
121VUAPU/FUEL/LP VALVE/SPLY2QFM39
121VUEIS/HORN/SPLY2WCP09
4. Procedure
Subtask 26-22-00-710-135-A
WARNING: DO NOT PUSH THE TEST PUSHBUTTON SWITCH ON THE APU/AUTO EXTING SECTION OF OVERHEAD PANEL 50VU WHILE THE APU IS IN OPERATION. IF YOU DO, DISCHARGE OF THE APU-FIRE EXTINGUISHER BOTTLE CAN OCCUR.
A. Test for ECB PN: 304640-2
ACTION
RESULT
1.In the INT LT section of overhead panel 25VU:
  • Set the ANN LT switch to the TEST position.
In the cockpit:
  • All annunciator lights come on fully brightly.
2.In the INT LT section of overhead panel 25VU:
  • Set the ANN LT switch to the BRT position.
In the cockpit:
  • The applicable annunciator lights go off.
3.On circuit-breaker panel 121VU:
  • Open circuit breaker APU/FUEL/LP VALVE/CTL 1QF.

4.On overhead panel 25VU:
  • Push the APU MASTER SW pushbutton switch.
On overhead panel 25VU:
  • The ON legend of the APU MASTER SW pushbutton switch comes on.
5.On the ECAM control panel:
  • Push the FUEL pushbutton switch.
On the ECAM lower display unit:
  • The FUEL page comes into view.

On the FUEL page of the ECAM lower display unit:
  • The APU LP fuel-valve symbol is shown in open position.
6.In the APU/AUTO EXTING section of overhead panel 50VU:
  • Push the TEST pushbutton switch.
NOTE: This test causes a spurious WARNING in ECAM (APU FIRE LOOP A FAULT) because of a FDU hardware modification.
In the APU/AUTO EXTING section of overhead panel 50VU:
  • The ON legend of the APU/AUTO EXTING/TEST pushbutton switch comes on.
  • The OK legend of the APU/AUTO EXTING/TEST pushbutton switch comes on after approximately 10 seconds.

On APU FIRE panel 20VU:
  • The light of the APU FIRE pushbutton switch comes on.
  • The first and third columns of the APU FIRE lights come on.

On overhead panel 25VU:
  • The FAULT legend of the APU MASTER SW pushbutton switch comes on.

On glareshield panels 130VU and 131VU:
  • The MASTER CAUT lights come on.
  • A single chime operates.

On the FUEL page of the ECAM lower display unit:
  • The APU LP fuel-valve symbol is shown in closed position.

On external power control panel 108VU:
  • The APU FIRE light comes on.
  • The ground warning horn operates.
NOTE: When the ground warning horn operates, you can switch it off when you open circuit breaker EIS/HORN/SPLY 2WC. This prevents the ground warning horn operates when not necessary.
7.In the APU/AUTO EXTING section of panel 50VU:
  • Push the RESET pushbutton switch.
In the APU/AUTO EXTING section of panel 50VU:
  • The ON legend of the TEST pushbutton switch goes off.
  • The OK legend of the TEST pushbutton switch goes off.

On APU FIRE panel 20VU:
  • The APU FIRE light of the APU FIRE pushbutton switch goes off.
  • The first and third columns of the APU FIRE lights go off.

On external power panel 108VU:
  • The APU FIRE light goes off.
If circuit breaker 2WC was not opened:
  • The ground warning horn goes off.

On overhead panel 25VU:
  • The FAULT legend in the APU MASTER SW pushbutton switch goes off.
8.On glareshield panel 130VU or 131VU:
  • Push the MASTER CAUT pushbutton switch.
On glareshield panels 130VU and 131VU:
  • The MASTER CAUT lights go off.
9.On overhead panel 25VU:
  • Release the APU MASTER SW pushbutton switch.
On overhead panel 25VU:
  • The ON legend of the APU MASTER SW pushbutton switch goes off.

On the FUEL page of the ECAM lower display unit:
  • The APU LP fuel-valve symbol is shown in open position and then in closed position.
10.On circuit-breaker panel 121VU:
  • Close circuit breaker APU/FUEL/LP VALVE/CTL 1QF,
  • Open circuit breaker APU/FUEL/LP VALVE/SPLY 2QF.

11.On overhead panel 25VU:
  • Push the APU MASTER SW pushbutton switch.
On overhead panel 25VU:
  • The ON legend of the APU MASTER SW pushbutton switch comes on.
12.On the ECAM control panel:
  • Push the FUEL pushbutton switch.
On the ECAM lower display unit:
  • The FUEL page comes into view.

On the FUEL page of the ECAM lower display unit:
  • The APU LP fuel-valve symbol is shown in open position.
13.In the APU/AUTO EXTING section of panel 50VU:
  • Push the TEST pushbutton switch.
NOTE: This test causes a spurious WARNING in ECAM (APU FIRE LOOP A FAULT) because of a FDU hardware modification.
In the APU/AUTO EXTING section of panel 50VU:
  • The ON legend of the TEST pushbutton switch comes on.
  • The OK legend of the TEST pushbutton switch comes on after approximately 10 seconds.

On APU FIRE panel 20VU:
  • The APU FIRE light of the APU FIRE pushbutton switch comes on.
  • The first and third columns of the APU FIRE lights come on.

On overhead panel 25VU:
  • The FAULT legend of the APU MASTER SW pushbutton switch comes on.

On glareshield panels 130VU and 131VU:
  • The MASTER CAUT lights come on.
  • A single chime operates.

On the FUEL page of the ECAM lower display unit:
  • The APU LP fuel-valve symbol is shown in closed position.

On external power control panel 108VU:
  • The APU FIRE light comes on.
If circuit breaker 2WC was not opened:
  • The ground warning horn operates.
14.In the APU/AUTO EXTING section of panel 50VU:
  • Push the RESET pushbutton switch.
In the APU/AUTO EXTING section of panel 50VU:
  • The ON legend in the TEST pushbutton switch goes off.
  • The OK legend in the TEST pushbutton switch goes off.

On APU FIRE panel 20VU:
  • The APU FIRE light of the APU FIRE pushbutton switch goes off.
  • The first and third columns of the APU FIRE lights go off.

On external power control panel 108VU:
  • The APU FIRE light goes off.
If circuit breaker 2WC was not opened:
  • The ground warning horn goes off.

On overhead panel 25VU:
  • The FAULT legend of the APU MASTER SW pushbutton switch goes off.
15.On overhead panel 25VU:
  • Release the APU MASTER SW pushbutton switch.
On overhead panel 25VU:
  • The ON legend of the APU MASTER SW pushbutton switch goes off.

On the FUEL page of the ECAM lower display unit:
  • The APU LP fuel-valve symbol is shown in open position and then in closed position.
16.On glareshield panel 130VU or 131VU:
  • Push the MASTER CAUT pushbutton switch.
On glareshield panels 130VU and 131VU:
  • The MASTER CAUT lights go off.
17.On circuit-breaker panel 121VU:
  • Close circuit breaker APU/FUEL/LP VALVE/SPLY 2QF.
If circuit breaker 2WC was opened:
  • Close circuit breaker 2WC.

18.On overhead panel 25VU:
  • Push the APU MASTER SW pushbutton switch.
On overhead panel 25VU:
  • The ON legend of the APU MASTER SW pushbutton switch comes on.
19.On the ECAM control panel:
  • Push the FUEL pushbutton switch.
On the ECAM lower display unit:
  • The FUEL page comes into view.

On the FUEL page of the ECAM lower display unit:
  • The APU LP fuel-valve symbol is shown in open position.
20.On external power control panel 108VU:
  • Push and hold the APU SHUT OFF pushbutton switch (guard in red).
On the FUEL page of the ECAM lower display unit:
  • The APU LP fuel-valve symbol is shown in closed position.

On glareshield panels 130VU and 131VU:
  • The MASTER CAUT lights come on.
  • A single chime operates.

On overhead panel 25VU:
  • The FAULT legend of the APU MASTER SW pushbutton switch comes on.
21.On external power control panel 108VU:
  • Release the APU SHUT OFF pushbutton switch and close the guard.
On overhead panel 25VU:
  • The FAULT legend of the APU MASTER SW pushbutton switch goes off.
22.On glareshield panel 130VU or 131VU:
  • Push the MASTER CAUT pushbutton switch.
On glareshield panels 130VU and 131VU:
  • The MASTER CAUT lights go off.
23.On overhead panel 25VU:
  • Release the APU MASTER SW pushbutton switch.
On overhead panel 25VU:
  • The ON legend of the APU MASTER SW pushbutton switch goes off.

On the FUEL page of the ECAM lower display unit:
  • The APU LP fuel-valve symbol is shown in open position and then in closed position.
24.On overhead panel 25VU:
  • Push the APU MASTER SW pushbutton switch.
On overhead panel 25VU:
  • The ON legend of the APU MASTER SW pushbutton switch comes on.

On the FUEL page of the ECAM lower display unit:
  • The APU LP fuel-valve symbol is shown in open position.
25.On APU FIRE panel 20VU:
  • Lift the guard and release the APU FIRE pushbutton switch.
On APU FIRE panel 20VU:
  • The SQUIB legend of the AGENT pushbutton switch comes on.

On glareshield panels 130VU and 131VU:
  • The MASTER CAUT lights come on.
  • A single chime operates.

On overhead panel 25VU:
  • The FAULT legend of the APU MASTER SW pushbutton switch comes on.

On the FUEL page of the ECAM lower display unit:
  • The APU LP fuel-valve symbol is shown in closed position.
26.On APU FIRE panel 20VU:
  • Push the APU FIRE pushbutton switch and close the guard.
On APU FIRE panel 20VU:
  • The SQUIB legend of the AGENT pushbutton switch goes off.

On overhead panel 25VU:
  • The FAULT legend of the APU MASTER SW pushbutton switch goes off.
27.On overhead panel 25VU:
  • Release the APU MASTER SW pushbutton switch.
On overhead panel 25VU:
  • The ON legend of the APU MASTER SW pushbutton switch goes off.

On the FUEL page of the ECAM lower display unit:
  • The APU LP fuel-valve symbol is shown in open position and then in closed position.

28.On glareshield panel 130VU or 131VU:
  • Push the MASTER CAUT pushbutton switch.
On glareshield panels 130VU and 131VU:
  • The MASTER CAUT lights go off.
Subtask 26-22-00-710-137-B
WARNING: DO NOT PUSH THE TEST PUSHBUTTON SWITCH ON THE APU/AUTO EXTING SECTION OF OVERHEAD PANEL 50VU WHILE THE APU IS IN OPERATION. IF YOU DO, DISCHARGE OF THE APU-FIRE EXTINGUISHER BOTTLE CAN OCCUR.
B. Test for ECB other than PN: 3888394-XXXXXX, 3888579-XXX, 450000XX, 304640-2 and 304817-X
ACTION
RESULT
1.In the INT LT section of overhead panel 25VU:
  • Set the ANN LT switch to the TEST position.
In the cockpit:
  • All annunciator lights come on fully brightly.
2.In the INT LT section of overhead panel 25VU:
  • Set the ANN LT switch to the BRT position.
In the cockpit:
  • The applicable annunciator lights go off.
3.On circuit-breaker panel 121VU:
  • Open circuit breaker APU/FUEL/LP VALVE/CTL 1QF.

4.On overhead panel 25VU:
  • Push the APU MASTER SW pushbutton switch
On overhead panel 25VU:
  • The ON legend of the APU MASTER SW pushbutton switch comes on.
5.On the ECAM control panel:
  • Push the FUEL pushbutton switch.
On the ECAM lower display unit:
  • The FUEL page comes into view.

On the FUEL page of the ECAM lower display unit:
  • The APU LP fuel-valve symbol is shown in open position.
6.In the APU/AUTO EXTING section of panel 50VU:
  • Push the TEST pushbutton switch.
NOTE: This test causes a spurious WARNING in ECAM (APU FIRE LOOP A FAULT) because of a FDU hardware modification.
In the APU/AUTO EXTING section of overhead panel 50VU:
  • The ON legend of the TEST pushbutton switch comes on.
  • The OK legend of the TEST pushbutton switch comes on after approximately 3 seconds.

On APU FIRE panel 20VU:
  • The APU FIRE light of the APU FIRE pushbutton switch comes on.
  • The first and third columns of the APU FIRE lights come on.

On overhead panel 25VU:
  • The FAULT legend of the APU MASTER SW pushbutton switch comes on.

On glareshield panels 130VU and 131VU:
  • The MASTER CAUT lights come on.
  • A single chime operates.

On the ECAM upper display unit:
  • The warning APU EMER SHUT DOWN MASTER SW....OFF comes on.

On the FUEL page of the ECAM lower display unit:
  • The APU LP fuel-valve symbol is shown in closed position.

On external power control panel 108VU:
  • The APU FIRE light comes on.
  • The ground warning horn operates.
NOTE: When the ground warning horn operates, you can switch it off when you open circuit breaker EIS/HORN/SPLY 2WC. This prevents the ground warning horn operates when not necessary.
7.In the APU/AUTO EXTING section of panel 50VU:
  • Push the RESET pushbutton switch.
In the APU/AUTO EXTING section of panel 50VU:
  • The ON legend of the TEST pushbutton switch goes off.
  • The OK legend of the TEST pushbutton switch goes off.

On APU FIRE panel 20VU:
  • The APU FIRE light of the APU FIRE pushbutton switch goes off.
  • The first and third columns of the APU FIRE lights go off.

On external power panel 108VU:
  • The APU FIRE light goes off.
If circuit breaker 2WC was not opened:
  • The ground warning horn goes off.

On overhead panel 25VU:
  • The FAULT legend of the APU MASTER SW pushbutton switch goes off.
8.On overhead panel 25VU:
  • Release the APU MASTER SW pushbutton switch.
On overhead panel 25VU:
  • The ON legend of the APU MASTER SW pushbutton switch goes off.

On the ECAM upper display unit:
  • The warning MASTER SW....OFF goes off.

On the FUEL page of the ECAM lower display unit:
  • The APU LP fuel-valve symbol is shown in open position and then in closed position.
9.On glareshield panel 130VU or 131VU:
  • Push the MASTER CAUT pushbutton switch.
On glareshield panels 130VU and 131VU:
  • The MASTER CAUT lights go off.
10.On overhead panel 25VU:
  • Push the APU MASTER SW pushbutton switch two times (on/off) to reset the ECB.
On the ECAM upper display unit:
  • The warning APU EMER SHUT DOWN goes off.
11.On circuit-breaker panel 121VU:
  • Close circuit breaker APU/FUEL/LP VALVE/CTL 1QF,
  • Open circuit breaker APU/FUEL/LP VALVE/SPLY 2QF.

12.On overhead panel 25VU:
  • Push the APU MASTER SW pushbutton switch to the ON position.
On overhead panel 25VU:
  • The ON legend of the APU MASTER SW pushbutton switch comes on.
13.On the ECAM control panel:
  • Push the FUEL pushbutton switch.
On the ECAM lower display unit:
  • The FUEL page comes into view.

On the FUEL page of the ECAM lower display unit:
  • The APU LP fuel-valve symbol is shown in open position.
14.In the APU/AUTO EXTING section of panel 50VU:
  • Push the TEST pushbutton switch.
NOTE: This test causes a spurious WARNING in ECAM (APU FIRE LOOP A FAULT) because of a FDU hardware modification.
In the APU/AUTO EXTING section of panel 50VU:
  • The ON legend of the TEST pushbutton switch comes on.
  • The OK legend of the TEST pushbutton switch comes on after approximately 3 seconds.

On APU FIRE panel 20VU:
  • The APU FIRE light of the APU FIRE pushbutton switch comes on.
  • The first and third columns of the APU FIRE lights come on.

On overhead panel 25VU:
  • The FAULT legend of the APU MASTER SW pushbutton switch comes on.

On glareshield panels 130VU and 131VU:
  • The MASTER CAUT lights come on.
  • A single chime operates.

On the ECAM upper display unit:
  • The warning APU EMER SHUT DOWN MASTER SW....OFF comes on.

On the FUEL page of the ECAM lower display unit:
  • The APU LP fuel-valve symbol is shown in closed position.

On external power control panel 108VU:
  • The APU FIRE light comes on.
If circuit breaker 2WC was not opened:
  • The ground warning horn operates.
15.In the APU/AUTO EXTING section of panel 50VU:
  • Push the RESET pushbutton switch.
On overhead panel 25VU:
  • The FAULT legend of the APU MASTER SW pushbutton switch goes off.

In the APU/AUTO EXTING section of panel 50VU:
  • The ON legend of the TEST pushbutton switch goes off.
  • The OK legend of the TEST pushbutton switch goes off.

On APU FIRE panel 20VU:
  • The APU FIRE light of the APU FIRE pushbutton switch goes off.
  • The first and third columns of the APU FIRE lights go off.

On external power control panel 108VU:
  • The APU FIRE light goes off.
If circuit breaker 2WC was not opened:
  • The ground warning horn goes off.
16.On overhead panel 25VU:
  • Release the APU MASTER SW pushbutton switch.
On overhead panel 25VU:
  • The ON legend of the APU MASTER SW pushbutton switch goes off.

On the ECAM upper display unit:
  • The warning MASTER SW....OFF goes off.

On the FUEL page of the ECAM lower display unit:
  • The APU LP fuel-valve symbol is shown in open position and then in closed position.
17.On glareshield panel 130VU or 131VU:
  • Push the MASTER CAUT pushbutton switch.
On glareshield panels 130VU and 131VU:
  • The MASTER CAUT lights go off.
18.On overhead panel 25VU:
  • Push the APU MASTER SW pushbutton switch two times (on/off) to reset the ECB.
On the ECAM upper display unit:
  • The warning APU EMER SHUT DOWN goes off.
19.On circuit-breaker panel 121VU:
  • Close circuit breaker APU/FUEL/LP VALVE/SPLY 2QF.
If circuit breaker 2WC was opened:
  • Close circuit breaker 2WC.

20.On overhead panel 25VU:
  • Push the APU MASTER SW pushbutton switch to the ON position.
On overhead panel 25VU:
  • The ON legend of the APU MASTER SW pushbutton switch comes on.

On the FUEL page of the ECAM lower display unit:
  • The APU LP fuel-valve symbol is shown in open position.
21.On external power control panel 108VU:
  • Push and hold the APU SHUT OFF pushbutton switch (guard in red).
On the ECAM upper display unit:
  • The warning APU EMER SHUT DOWN MASTER SW....OFF comes on.

On glareshield panels 130VU and 131VU:
  • The MASTER CAUT lights come on.
  • A single chime operates.

On overhead panel 25VU:
  • The FAULT legend of the APU MASTER SW pushbutton switch comes on.

On the FUEL page of the ECAM lower display unit:
  • The APU LP fuel-valve symbol is shown in closed position.
22.On external power control panel 108VU:
  • Release the APU SHUT OFF pushbutton switch and close the guard.
On overhead panel 25VU:
  • The FAULT legend of the APU MASTER SW pushbutton switch goes off.
23.On glareshield panel 130VU or 131VU:
  • Push the MASTER CAUT pushbutton switch.
On glareshield panels 130VU and 131VU:
  • The MASTER CAUT lights go off.
24.On overhead panel 25VU:
  • Release the APU MASTER SW pushbutton switch.
On overhead panel 25VU:
  • The ON legend of the APU MASTER SW pushbutton switch goes off.

On the ECAM upper display unit:
  • The warning APU EMER SHUT DOWN MASTER SW....OFF goes off.

On the FUEL page of the ECAM lower display unit:
  • The APU LP fuel-valve symbol is shown in open position and then in closed position.
25.On overhead panel 25VU:
  • Push the APU MASTER SW pushbutton switch two times (on/off) to reset the ECB.
On the ECAM upper display unit:
  • The warning APU EMER SHUT DOWN goes off.
26.On overhead panel 25VU:
  • Push the APU MASTER SW pushbutton switch to the ON position.
On overhead panel 25VU:
  • The ON legend of the APU MASTER SW pushbutton switch comes on.

On the FUEL page of the ECAM lower display unit:
  • The APU LP fuel-valve symbol is shown in open position.
27.On APU FIRE panel 20VU:
  • Lift the guard and release the APU FIRE pushbutton switch.
On APU FIRE panel 20VU:
  • The SQUIB legend of the AGENT pushbutton switch comes on.

On the ECAM upper display unit:
  • The warning APU EMER SHUT DOWN MASTER SW....OFF comes on.

On glareshield panels 130VU and 131VU:
  • The MASTER CAUT lights come on.
  • A single chime operates.

On overhead panel 25VU:
  • The FAULT legend of the APU MASTER SW pushbutton switch comes on.

On the FUEL page of the ECAM lower display unit:
  • The APU LP fuel-valve symbol is shown in closed position.
28.On APU FIRE panel 20VU:
  • Push the APU FIRE pushbutton switch and close the guard.
On APU FIRE panel 20VU:
  • The SQUIB legend of the AGENT pushbutton switch goes off.

On overhead panel 25VU:
  • The FAULT legend of the APU MASTER SW pushbutton switch goes off.
29.On overhead panel 25VU:
  • Release the APU MASTER SW pushbutton switch.
On overhead panel 25VU:
  • The ON legend of the APU MASTER SW pushbutton switch goes off.

On the ECAM upper display unit:
  • The warning MASTER SW....OFF goes off.

On the FUEL page of the ECAM lower display unit:
  • The APU LP fuel-valve symbol is shown in open position and then in closed position.

30.On glareshield panel 130VU or 131VU:
  • Push the MASTER CAUT pushbutton switch.
On glareshield panels 130VU and 131VU:
  • The MASTER CAUT lights go off.
31.On overhead panel 25VU:
  • Push the APU MASTER SW pushbutton switch two times (on/off) to reset the ECB.
On the ECAM upper display unit:
  • The warning APU EMER SHUT DOWN goes off.
Subtask 26-22-00-710-138-B
WARNING: DO NOT PUSH THE TEST PUSHBUTTON SWITCH ON THE APU/AUTO EXTING SECTION OF OVERHEAD PANEL 50VU WHILE THE APU IS IN OPERATION. IF YOU DO, DISCHARGE OF THE APU-FIRE EXTINGUISHER BOTTLE CAN OCCUR.
C. Test for ECB PN: 3888394-XXXXXX, 3888579-XXX and 450000XX
ACTION
RESULT
1.In the INT LT section of overhead panel 25VU:
  • Set the ANN LT switch to the TEST position.
In the cockpit:
  • All annunciator lights come on fully brightly.
2.In the INT LT section of overhead panel 25VU:
  • Set the ANN LT switch to the BRT position.
In the cockpit:
  • The applicable annunciator lights go off.
3.On circuit-breaker panel 121VU:
  • Open circuit breaker APU/FUEL/LP VALVE/CTL 1QF.

4.On overhead panel 25VU:
  • Push the APU MASTER SW pushbutton switch.
On overhead panel 25VU:
  • The ON legend of the APU MASTER SW pushbutton switch comes on.
5.On the ECAM control panel:
  • Push the FUEL pushbutton switch.
On the ECAM lower display unit:
  • The FUEL page comes into view.

On the FUEL page of the ECAM lower display unit:
  • The APU LP fuel-valve symbol is shown in open position.
6.In the APU/AUTO EXTING section of overhead panel 50VU:
  • Push the TEST pushbutton switch.
NOTE: This test causes a spurious WARNING in ECAM (APU FIRE LOOP A FAULT) because of a FDU hardware modification.
In the APU/AUTO EXTING section of overhead panel 50VU:
  • The ON legend of the TEST pushbutton switch comes on.
  • The OK legend of the TEST pushbutton switch comes on after approximately 3 seconds.

On APU FIRE panel 20VU:
  • The APU FIRE light of the APU FIRE pushbutton switch comes on.
  • The first and third columns of the APU FIRE lights come on.

On overhead panel 25VU:
  • The FAULT legend of the APU MASTER SW pushbutton switch comes on.

On glareshield panels 130VU and 131VU:
  • The MASTER CAUT lights come on.
  • A single chime operates.

On the ECAM upper display unit:
  • The warning APU EMER SHUT DOWN MASTER SW....OFF comes on.

On the FUEL page of the ECAM lower display unit:
  • The APU LP fuel-valve symbol is shown in closed position.

On external power control panel 108VU:
  • The APU FIRE light comes on.
  • The ground warning horn operates.
NOTE: When the ground warning horn operates, you can switch it off when you open circuit breaker EIS/HORN/SPLY 2WC. This prevents the ground warning horn operates when not necessary.
7.In the APU/AUTO EXTING section of panel 50VU:
  • Push the RESET pushbutton switch.
In the APU/AUTO EXTING section of panel 50VU:
  • The ON legend of the TEST pushbutton switch goes off.
  • The OK legend of the TEST pushbutton switch goes off.

On APU FIRE panel 20VU:
  • The APU FIRE light of the APU FIRE pushbutton switch goes off.
  • The first and third columns of the APU FIRE lights go off.

On external power panel 108VU:
  • The APU FIRE light goes off.
If circuit breaker 2WC was not opened:
  • The ground warning horn goes off.
8.On overhead panel 25VU:
  • Release the APU MASTER SW pushbutton switch.
On overhead panel 25VU:
  • The FAULT legend of the APU MASTER SW pushbutton switch goes off.
  • The ON legend of the APU MASTER SW pushbutton switch goes off.

On the ECAM upper display unit:
  • The warning MASTER SW....OFF goes off.
9.On glareshield panel 130VU or 131VU:
  • Push the MASTER CAUT pushbutton switch.
On glareshield panels 130VU and 131VU:
  • The MASTER CAUT lights go off.
10.On overhead panel 25VU:
  • Push the APU MASTER SW pushbutton switch two times (on/off) to reset the ECB.
On the ECAM upper display unit:
  • The warning APU EMER SHUT DOWN goes off.
11.On circuit-breaker panel 121VU:
  • Close circuit breaker APU/FUEL/LP VALVE/CTL 1QF,
  • Open circuit breaker APU/FUEL/LP VALVE/SPLY 2QF.

12.On overhead panel 25VU:
  • Push the APU MASTER SW pushbutton switch to the ON position.
On overhead panel 25VU:
  • The ON legend of the APU MASTER SW pushbutton switch comes on.
13.On the ECAM control panel:
  • Push the FUEL pushbutton switch.
On the ECAM lower display unit:
  • The FUEL page comes into view.

On the FUEL page of the ECAM lower display unit:
  • The APU LP fuel-valve symbol is shown in open position.
14.In the APU/AUTO EXTING section of panel 50VU:
  • Push the TEST pushbutton switch.
NOTE: This test causes a spurious WARNING in ECAM (APU FIRE LOOP A FAULT) because of a FDU hardware modification.
In the APU/AUTO EXTING section of panel 50VU:
  • The ON legend of the TEST pushbutton switch comes on.
  • The OK legend of the TEST pushbutton switch comes on after approximately 3 seconds.

On APU FIRE panel 20VU:
  • The APU FIRE light of the APU FIRE pushbutton switch comes on.
  • The first and third columns of the APU FIRE lights come on.

On overhead panel 25VU:
  • The FAULT legend of the APU MASTER SW pushbutton switch comes on.

On glareshield panels 130VU and 131VU:
  • The MASTER CAUT lights come on.
  • A single chime operates.

On the ECAM upper display unit:
  • The warning APU EMER SHUT DOWN MASTER SW....OFF comes on.

On the FUEL page of the ECAM lower display unit:
  • The APU LP fuel-valve symbol is shown in closed position.

On external power control panel 108VU:
  • The APU FIRE light comes on.
If circuit breaker 2WC was not opened:
  • The ground warning horn operates.
15.In the APU/AUTO EXTING section of panel 50VU:
  • Push the RESET pushbutton switch.
In the APU/AUTO EXTING section of panel 50VU:
  • The ON legend of the TEST pushbutton switch goes off.
  • The OK legend of the TEST pushbutton switch goes off.

On APU FIRE panel 20VU:
  • The APU FIRE light of the APU FIRE pushbutton switch goes off.
  • The first and third columns of the APU FIRE lights go off.

On external power control panel 108VU:
  • The APU FIRE light goes off.
If circuit breaker 2WC was not opened:
  • The ground warning horn goes off.
16.On overhead panel 25VU:
  • Release the APU MASTER SW pushbutton switch.
On overhead panel 25VU:
  • The FAULT legend of the APU MASTER SW pushbutton switch goes off.
  • The ON legend of the APU MASTER SW pushbutton switch goes off.

On the ECAM upper display unit:
  • The warning MASTER SW....OFF goes off.
17.On glareshield panel 130VU or 131VU:
  • Push the MASTER CAUT pushbutton switch.
On glareshield panels 130VU and 131VU:
  • The MASTER CAUT lights go off.
18.On overhead panel 25VU:
  • Push the APU MASTER SW pushbutton switch two times (on/off) to reset the ECB.
On the ECAM upper display unit:
  • The warning APU EMER SHUT DOWN goes off.
19.On circuit-breaker panel 121VU:
  • Close circuit breaker APU/FUEL/LP VALVE/SPLY 2QF.
If circuit breaker 2WC was opened:
  • Close circuit breaker 2WC.

20.On overhead panel 25VU:
  • Push the APU MASTER SW pushbutton switch.
On overhead panel 25VU:
  • The ON legend of the APU MASTER SW pushbutton switch comes on.

On the FUEL page of the ECAM lower display unit:
  • The APU LP fuel-valve symbol is shown in open position.
21.On external power control panel 108VU:
  • Push and hold the APU SHUT OFF pushbutton switch (guard in red).
On the ECAM upper display unit:
  • The warning APU EMER SHUT DOWN MASTER SW....OFF comes on.

On glareshield panels 130VU and 131VU:
  • The MASTER CAUT lights come on.
  • A single chime operates.

On overhead panel 25VU:
  • The FAULT legend of the APU MASTER SW pushbutton switch comes on.

On the FUEL page of the ECAM lower display unit:
  • The APU LP fuel-valve symbol is shown in closed position.
22.On external power control panel 108VU:
  • Release the APU SHUT OFF pushbutton switch and close the guard.

23.On glareshield panel 130VU or 131VU:
  • Push the MASTER CAUT pushbutton switch.
On glareshield panels 130VU and 131VU:
  • The MASTER CAUT lights go off.
24.On overhead panel 25VU:
  • Release the APU MASTER SW pushbutton switch.
On overhead panel 25VU:
  • The FAULT legend of the APU MASTER SW pushbutton switch goes off.
  • The ON legend of the APU MASTER SW pushbutton switch goes off.

On the ECAM upper display unit:
  • The warning MASTER SW....OFF goes off.
25.On overhead panel 25VU:
  • Push the APU MASTER SW pushbutton switch two times (on/off) to reset the ECB.
On the ECAM upper display unit:
  • The warning APU EMER SHUT DOWN goes off.
26.On overhead panel 25VU:
  • Push the APU MASTER SW pushbutton switch.
On overhead panel 25VU:
  • The ON legend of the APU MASTER SW pushbutton switch comes on.

On the FUEL page of the ECAM lower display unit:
  • The APU LP fuel-valve symbol is shown in open position.
27.On APU FIRE panel 20VU:
  • Lift the guard and release the APU FIRE pushbutton switch.
On APU FIRE panel 20VU:
  • The SQUIB legend of the AGENT pushbutton switch comes on.

On the ECAM upper display unit:
  • The warning APU EMER SHUT DOWN MASTER SW....OFF comes on.

On glareshield panels 130VU and 131VU:
  • The MASTER CAUT lights come on.
  • A single chime operates.

On overhead panel 25VU:
  • The FAULT legend of the APU MASTER SW pushbutton switch comes on.

On the FUEL page of the ECAM lower display unit:
  • The APU LP fuel-valve symbol is shown in closed position.
28.On APU FIRE panel 20VU:
  • Push the APU FIRE pushbutton switch and close the guard.
On APU FIRE panel 20VU:
  • The SQUIB legend of the AGENT pushbutton switch goes off.
29.On overhead panel 25VU:
  • Release the APU MASTER SW pushbutton switch.
On overhead panel 25VU:
  • The FAULT legend of the APU MASTER SW pushbutton switch goes off.
  • The ON legend of the APU MASTER SW pushbutton switch goes off.

On the ECAM upper display unit:
  • The warning MASTER SW....OFF goes off.

30.On glareshield panel 130VU or 131VU:
  • Push the MASTER CAUT pushbutton switch.
On glareshield panels 130VU and 131VU:
  • The MASTER CAUT lights go off.
31.On overhead panel 25VU:
  • Push the APU MASTER SW pushbutton switch two times (on/off) to reset the ECB.
On the ECAM upper display unit:
  • The warning APU EMER SHUT DOWN goes off.
Subtask 26-22-00-710-139-B
WARNING: DO NOT PUSH THE TEST PUSHBUTTON SWITCH ON THE APU/AUTO EXTING SECTION OF OVERHEAD PANEL 50VU WHILE THE APU IS IN OPERATION. IF YOU DO, DISCHARGE OF THE APU-FIRE EXTINGUISHER BOTTLE CAN OCCUR.
D. Test for ECB PN: 304817-X
ACTION
RESULT
1.In the INT LT section of overhead panel 25VU:
  • Set the ANN LT switch to the TEST position.
In the cockpit:
  • All annunciator lights come on fully brightly.
2.In the INT LT section of overhead panel 25VU:
  • Set the ANN LT switch to the BRT position.
In the cockpit:
  • The applicable annunciator lights go off.
3.On circuit-breaker panel 121VU:
  • Open circuit breaker APU/FUEL/LP VALVE/CTL 1QF.

4.On overhead panel 25VU:
  • Push the APU MASTER SW pushbutton switch.
On overhead panel 25VU:
  • The ON legend of the APU MASTER SW pushbutton switch comes on.
5.On the ECAM control panel:
  • Push the FUEL pushbutton switch.
On the ECAM lower display unit:
  • The FUEL page comes into view.

On the FUEL page of the ECAM lower display unit:
  • The APU LP fuel-valve symbol is shown in open position.
6.In the APU/AUTO EXTING section of overhead panel 50VU:
  • Push the TEST pushbutton switch.
NOTE: This test causes a spurious WARNING in ECAM (APU FIRE LOOP A FAULT) because of a FDU hardware modification.
In the APU/AUTO EXTING section of overhead panel 50VU:
  • The ON legend of the TEST pushbutton switch comes on.
  • The OK legend of the TEST pushbutton switch comes on after approximately 3 seconds.

On APU FIRE panel 20VU:
  • The APU FIRE light of the APU FIRE pushbutton switch comes on.
  • The first and third columns of the APU FIRE lights come on.

On overhead panel 25VU:
  • The FAULT legend of the APU MASTER SW pushbutton switch comes on.

On glareshield panels 130VU and 131VU:
  • The MASTER CAUT lights come on.
  • A single chime operates.

On the ECAM upper display unit:
  • The warning APU EMER SHUT DOWN MASTER SW....OFF comes on.

On the FUEL page of the ECAM lower display unit:
  • The APU LP fuel-valve symbol is shown in closed position.

On external power control panel 108VU:
  • The APU FIRE light comes on.
  • The ground warning horn operates.
NOTE: When the ground warning horn operates, you can switch it off when you open circuit breaker EIS/HORN/SPLY 2WC. This prevents the ground warning horn operates when not necessary.
7.In the APU/AUTO EXTING section of panel 50VU:
  • Push the RESET pushbutton switch.
In the APU/AUTO EXTING section of panel 50VU:
  • The ON legend of the TEST pushbutton switch goes off.
  • The OK legend of the TEST pushbutton switch goes off.

On APU FIRE panel 20VU:
  • The APU FIRE light of the APU FIRE pushbutton switch goes off.
  • The first and third columns of the APU FIRE lights go off.

On external power panel 108VU:
  • The APU FIRE light goes off.
If circuit breaker 2WC was not opened:
  • The ground warning horn goes off.

On overhead panel 25VU:
  • The FAULT legend of the APU MASTER SW pushbutton switch goes off.
8.On overhead panel 25VU:
  • Release the APU MASTER SW pushbutton switch.
On overhead panel 25VU:
  • The ON legend of the APU MASTER SW pushbutton switch goes off.

On the ECAM upper display unit:
  • The warning MASTER SW....OFF goes off.
9.On glareshield panel 130VU or 131VU:
  • Push the MASTER CAUT pushbutton switch.
On glareshield panels 130VU and 131VU:
  • The MASTER CAUT lights go off.
10.On overhead panel 25VU:
  • Push the APU MASTER SW pushbutton switch two times (on/off) to reset the ECB.
On the ECAM upper display unit:
  • The warning APU EMER SHUT DOWN goes off.
11.On circuit-breaker panel 121VU:
  • Close circuit breaker APU/FUEL/LP VALVE/CTL 1QF,
  • Open circuit breaker APU/FUEL/LP VALVE/SPLY 2QF.

12.On overhead panel 25VU:
  • Push the APU MASTER SW pushbutton switch to the ON position.
On overhead panel 25VU:
  • The ON legend of the APU MASTER SW pushbutton switch comes on.
13.On the ECAM control panel:
  • Push the FUEL pushbutton switch.
On the ECAM lower display unit:
  • The FUEL page comes into view.

On the FUEL page of the ECAM lower display unit:
  • The APU LP fuel-valve symbol is shown in open position.
14.In the APU/AUTO EXTING section of panel 50VU:
  • Push the TEST pushbutton switch.
NOTE: This test causes a spurious WARNING in ECAM (APU FIRE LOOP A FAULT) because of a FDU hardware modification.
In the APU/AUTO EXTING section of panel 50VU:
  • The ON legend of the TEST pushbutton switch comes on.
  • The OK legend of the TEST pushbutton switch comes on after approximately 3 seconds.

On APU FIRE panel 20VU:
  • The APU FIRE light of the APU FIRE pushbutton switch comes on.
  • The first and third columns of the APU FIRE lights come on.

On overhead panel 25VU:
  • The FAULT legend of the APU MASTER SW pushbutton switch comes on.

On glareshield panels 130VU and 131VU:
  • The MASTER CAUT lights come on.
  • A single chime operates.

On the ECAM upper display unit:
  • The warning APU EMER SHUT DOWN MASTER SW....OFF comes on.

On the FUEL page of the ECAM lower display unit:
  • The APU LP fuel-valve symbol is shown in closed position.

On external power control panel 108VU:
  • The APU FIRE light comes on.
If circuit breaker 2WC was not opened:
  • The ground warning horn operates.
15.In the APU/AUTO EXTING section of panel 50VU:
  • Push the RESET pushbutton switch.
In the APU/AUTO EXTING section of panel 50VU:
  • The ON legend of the TEST pushbutton switch goes off.
  • The OK legend of the TEST pushbutton switch goes off.

On APU FIRE panel 20VU:
  • The APU FIRE light of the APU FIRE pushbutton switch goes off.
  • The first and third columns of the APU FIRE lights go off.

On external power control panel 108VU:
  • The APU FIRE light goes off.
If circuit breaker 2WC was not opened:
  • The ground warning horn goes off.

On overhead panel 25VU:
  • The FAULT legend of the APU MASTER SW pushbutton switch goes off.
16.On overhead panel 25VU:
  • Release the APU MASTER SW pushbutton switch.
On overhead panel 25VU:
  • The ON legend of the APU MASTER SW pushbutton switch goes off.

On the ECAM upper display unit:
  • The warning MASTER SW....OFF goes off.
17.On glareshield panel 130VU or 131VU:
  • Push the MASTER CAUT pushbutton switch.
On glareshield panels 130VU and 131VU:
  • The MASTER CAUT lights go off.
18.On overhead panel 25VU:
  • Push the APU MASTER SW pushbutton switch two times (on/off) to reset the ECB.
On the ECAM upper display unit:
  • The warning APU EMER SHUT DOWN goes off.
19.On circuit-breaker panel 121VU:
  • Close circuit breaker APU/FUEL/LP VALVE/SPLY 2QF.
If circuit breaker 2WC was opened:
  • Close circuit breaker 2WC.

20.On overhead panel 25VU:
  • Push the APU MASTER SW pushbutton switch.
On overhead panel 25VU:
  • The ON legend of the APU MASTER SW pushbutton switch comes on.

On the FUEL page of the ECAM lower display unit:
  • The APU LP fuel-valve symbol is shown in open position.
21.On external power control panel 108VU:
  • Push and hold the APU SHUT OFF pushbutton switch (guard in red).
On the ECAM upper display unit:
  • The warning APU EMER SHUT DOWN MASTER SW....OFF comes on.

On glareshield panels 130VU and 131VU:
  • The MASTER CAUT lights come on.
  • A single chime operates.

On overhead panel 25VU:
  • The FAULT legend of the APU MASTER SW pushbutton switch comes on.

On the FUEL page of the ECAM lower display unit:
  • The APU LP fuel-valve symbol is shown in closed position.
22.On external power control panel 108VU:
  • Release the APU SHUT OFF pushbutton switch and close the guard.
On overhead panel 25VU:
  • The FAULT legend of the APU MASTER SW pushbutton switch goes off.
23.On glareshield panel 130VU or 131VU:
  • Push the MASTER CAUT pushbutton switch.
On glareshield panels 130VU and 131VU:
  • The MASTER CAUT lights go off.
24.On overhead panel 25VU:
  • Release the APU MASTER SW pushbutton switch.
On overhead panel 25VU:
  • The ON legend of the APU MASTER SW pushbutton switch goes off.

On the ECAM upper display unit:
  • The warning MASTER SW....OFF goes off.
25.On overhead panel 25VU:
  • Push the APU MASTER SW pushbutton switch two times (on/off) to reset the ECB.
On the ECAM upper display unit:
  • The warning APU EMER SHUT DOWN goes off.
26.On overhead panel 25VU:
  • Push the APU MASTER SW pushbutton switch.
On overhead panel 25VU:
  • The ON legend of the APU MASTER SW pushbutton switch comes on.

On the FUEL page of the ECAM lower display unit:
  • The APU LP fuel-valve symbol is shown in open position.
27.On APU FIRE panel 20VU:
  • Lift the guard and release the APU FIRE pushbutton switch.
On APU FIRE panel 20VU:
  • The SQUIB legend of the AGENT pushbutton switch comes on.

On the ECAM upper display unit:
  • The warning APU EMER SHUT DOWN MASTER SW....OFF comes on.

On glareshield panels 130VU and 131VU:
  • The MASTER CAUT lights come on.
  • A single chime operates.

On overhead panel 25VU:
  • The FAULT legend of the APU MASTER SW pushbutton switch comes on.

On the FUEL page of the ECAM lower display unit:
  • The APU LP fuel-valve symbol is shown in closed position.
28.On APU FIRE panel 20VU:
  • Push the APU FIRE pushbutton switch and close the guard.
On APU FIRE panel 20VU:
  • The SQUIB legend of the AGENT pushbutton switch goes off.

On overhead panel 25VU:
  • The FAULT legend of the APU MASTER SW pushbutton switch goes off.
29.On overhead panel 25VU:
  • Release the APU MASTER SW pushbutton switch.
On overhead panel 25VU:
  • The ON legend of the APU MASTER SW pushbutton switch goes off.

On the ECAM upper display unit:
  • The warning MASTER SW....OFF goes off.

30.On glareshield panel 130VU or 131VU:
  • Push the MASTER CAUT pushbutton switch.
On glareshield panels 130VU and 131VU:
  • The MASTER CAUT lights go off.
31.On overhead panel 25VU:
  • Push the APU MASTER SW pushbutton switch two times (on/off) to reset the ECB.
On the ECAM upper display unit:
  • The warning APU EMER SHUT DOWN goes off.
5. Close-up
Subtask 26-22-00-865-105-A
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUAPU/FUEL/PUMP/CTL3QCM38
Subtask 26-22-00-860-053-A
B. Put the aircraft back to its initial configuration.
   (1) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
   (2) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002) or (Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.03.31 23:45:30 UTC