Bottle Weight Check
TASK 26-22-00-040-004-A-01
Bottle Weight Check
1. Reason for the Job
MMEL 26-01-01-05A
APU AGENT PB DISCH LIGHT
2. Job Set-up Information
A. Referenced Information
3. Job Set-up
Subtask 26-22-00-010-061-A 4. Procedure
Subtask 26-22-00-280-053-A
Subtask 26-22-00-410-062-A
[Rev.10 from 2021]
2026.03.31 23:45:23 UTC
Bottle Weight Check
1. Reason for the Job
MMEL 26-01-01-05A
APU AGENT PB DISCH LIGHT
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TASK 26-22-41-000-001-A | Removal of the Fire Extinguisher Bottle |
| TASK 26-22-41-400-001-A | Installation of the Fire Extinguisher Bottle |
Subtask 26-22-00-010-061-A 4. Procedure
Subtask 26-22-00-280-053-A
A. Weigh the APU fire extinguisher bottle
(1) Make sure that the gross weight of the fire-extinguisher bottle is the same as the last weight shown on the identification plate, plus or minus 50 g (1.76 oz).
5. Close-up(1) Make sure that the gross weight of the fire-extinguisher bottle is the same as the last weight shown on the identification plate, plus or minus 50 g (1.76 oz).
NOTE: You must weigh the fire-extinguisher bottle without the discharge head and the cartridge. Compare the weight shown on the fire-extinguisher bottle with the weight shown on the identification plate. You must reject the fire-extinguisher bottle if the gross weight is not in the limits.
Subtask 26-22-00-410-062-A
A. Put the System back to its Operational Configuration
(1) Install the APU fire extinguisher bottle (11WF) (Ref. AMM TASK 26-22-41-400-001).
(2) Make an entry in the aircraft technical logbook.
(1) Install the APU fire extinguisher bottle (11WF) (Ref. AMM TASK 26-22-41-400-001).
(2) Make an entry in the aircraft technical logbook.