Removal of the Smoke-Detection Control Unit (SDCU)
TASK 26-17-34-000-001-A
Removal of the Smoke-Detection Control Unit (SDCU)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 26-17-34-861-050-A ** ON A/C NOT FOR ALL Subtask 26-17-34-810-050-A ** ON A/C NOT FOR ALL
Subtask 26-17-34-020-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 23:44:23 UTC
Removal of the Smoke-Detection Control Unit (SDCU)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 1M(3 FT) |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 122 | AVIONICS COMPARTMENT |
| 811 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 31-32-00-860-005-A | Procedure to Get Access to the SYSTEM REPORT/TEST FIRE PROT Page |
Subtask 26-17-34-861-050-A ** ON A/C NOT FOR ALL Subtask 26-17-34-810-050-A ** ON A/C NOT FOR ALL
B. Trouble Shooting Data (If the Computer Has This Function)
(1) You can print the Trouble Shooting Data (TSD) as follows:
Subtask 26-17-34-865-050-A ** ON A/C NOT FOR ALL (1) You can print the Trouble Shooting Data (TSD) as follows:
- get access to the SYSTEM REPORT/TEST FIRE PROT page (Ref. AMM TASK 31-32-00-860-005).
- on this page, push the line key adjacent to the SDCU indication.
- on the SDCU page, push the line key adjacent to the TROUBLE SHOOTING DATA indication to get the TROUBLE SHOOTING DATA page.
- print the TROUBLE SHOOTING DATA page.
C. Open, safety and tag this(these) circuit breaker(s):
Subtask 26-17-34-010-050-A ** ON A/C NOT FOR ALL 4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/SDCU/CHAN1 | 11WQ | C06 |
| 122VU | AIR COND/SDCU/CHAN2 | 12WQ | T18 |
Subtask 26-17-34-020-050-A ** ON A/C NOT FOR ALL
A. Remove the Smoke Detection Control Unit (SDCU)
(2) Remove the control unit (1) from the support (2).
(3) Put CAP - BLANKING on the electrical connector on the control unit (1) and on the receptacle on the rack (2).
CAUTION:
BE CAREFUL WHEN YOU REMOVE THE SDCU. THERE IS NO HANDLE ON IT (OTHER LRU'S HAVE A HANDLE). DO NOT USE MECHANICAL TOOLS. MECHANICAL TOOLS CAN CAUSE DAMAGE TO THE SDCU.
(1) Loosen the knurled nut (4), and disengage it from the control unit (1). (2) Remove the control unit (1) from the support (2).
(3) Put CAP - BLANKING on the electrical connector on the control unit (1) and on the receptacle on the rack (2).
Smoke-Detection Control Unit