W DOC AIRBUS | AMM A320F

Functional Test of the Lavatory Smoke-Detector Sensitivity


TASK 26-17-00-720-001-A
Functional Test of the Lavatory Smoke-Detector Sensitivity


ZONE: 200
1. Reason for the Job
Self Explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
MULTIMETER - STANDARD
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Consumable Materials
REFERENCE
DESIGNATION
No specific
test plug assembly
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
200
UPPER HALF FUSELAGE
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 26-17-15-000-001-A
Removal of the Lavatory Smoke Detector
TASK 26-17-15-000-008-A
Removal of the Lavatory Smoke Detector
TASK 26-17-15-400-001-A
Installation of the Lavatory Smoke Detector
TASK 26-17-15-400-007-A
Installation of the Lavatory Smoke Detector
TASK 31-32-00-860-005-A
Procedure to Get Access to the SYSTEM REPORT/TEST FIRE PROT Page
3. Job Set-up
Subtask 26-17-00-861-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 26-17-00-865-050-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR COND/SDCU/CHAN111WQC06
122VUAIR COND/SDCU/CHAN212WQT18
122VUAIR COND/LAV/GALLEY VENT CTL/EXTRACT FAN/CTL5HUU21
Subtask 26-17-00-010-057-A ** ON A/C NOT FOR ALL
C. For access only to the related lavatory smoke-detector (removal not necessary):
Subtask 26-17-00-480-050-AX ** ON A/C NOT FOR ALL
D. Preparation for the Test
   (1) Connect a test plug assembly and a MULTIMETER - STANDARD between the smoke detector and the electrical connector.
F Smoke-Detector Test Plug Assembly ** ON A/C NOT FOR ALL
NOTE: The minimum input resistance of the multimeter must be 10 MEG OHMS.
Subtask 26-17-00-865-051-A ** ON A/C NOT FOR ALL
E. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR COND/SDCU/CHAN111WQC06
122VUAIR COND/SDCU/CHAN212WQT18
4. Procedure
Subtask 26-17-00-720-051-A ** ON A/C NOT FOR ALL
A. Sensitivity Test of the Lavatory Smoke-Detector (ionization type smoke-detector) with the Part Number PAI 2830-00
NOTE: The voltage is between 6 and 6.5 VDC when the SDCU does an automatic test of the smoke detectors. The sensitivity check must be done after approximately 10 seconds, with the detector in stand-by condition.
   (1) Do this test:
ACTION
RESULT
1.On the test plug assembly:
On the multimeter:
  • Read the voltage shown on the multimeter.
  • The voltage is between 4 and 5 VDC.
Subtask 26-17-00-720-052-A ** ON A/C NOT FOR ALL
B. Sensitivity Test of the Lavatory Smoke-Detector (photo-electric type smoke-detector) with the Part Number PPA 12XX-XX or GPA 1202-00
ACTION
RESULT
1.On the test plug assembly:
On the multimeter:
  • Read the resistance shown on the multimeter.
  • The minimum resistance is 200 ohms.
Subtask 26-17-00-720-052-B ** ON A/C NOT FOR ALL
B. Sensitivity Test of the Lavatory Smoke-Detector (photo-electric type smoke-detector) with the Part Number PPA 12XX-XX or GPA 1202-00
ACTION
RESULT
1.On the test plug assembly:
On the multimeter:
  • Read the resistance shown on the multimeter.
  • The minimum resistance is 200 ohms.
Subtask 26-17-00-865-055-A ** ON A/C NOT FOR ALL
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR COND/SDCU/CHAN111WQC06
122VUAIR COND/SDCU/CHAN212WQT18
Subtask 26-17-00-420-052-A ** ON A/C NOT FOR ALL
D. Connect the smoke detector
   (1) Disconnect the electrical connectors of the test plug assembly.
   (2) Connect the electrical connector to the related smoke detector.
   (3) Repeat the test for each lavatory smoke detector.
Subtask 26-17-00-865-052-A ** ON A/C NOT FOR ALL
E. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR COND/SDCU/CHAN111WQC06
122VUAIR COND/SDCU/CHAN212WQT18
Subtask 26-17-00-710-051-A ** ON A/C NOT FOR ALL
F. Test
   (1) Do the test with the CFDS (Ref. AMM TASK 31-32-00-860-005).
5. Close-up
Subtask 26-17-00-410-056-A ** ON A/C NOT FOR ALL
A. For installation of items removed for access, refer to the related lavatory:
Subtask 26-17-00-862-050-A ** ON A/C NOT FOR ALL
B. Put the aircraft back to its initial configuration.
   (1) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.03.31 23:44:06 UTC