W DOC AIRBUS | AMM A320F

Check of the Wiring of the Smoke Detector Loop via MCDU


TASK 26-17-00-710-002-A
Check of the Wiring of the Smoke Detector Loop via MCDU


1. Reason for the Job
This test is a special check of the condition of the wiring. It allows a check of the wiring without performing a full BITE test of the SDCU.
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM 26-17-00-810-805
Smoke Detector(s) Wiring Fault
3. Job Set-up
Subtask 26-17-00-860-054-A ** ON A/C NOT FOR ALL
A. Get access to the Main Menu of the MCDU.
4. Procedure
Subtask 26-17-00-710-053-A ** ON A/C NOT FOR ALL
A. Test
   (1) On the MCDU:
  • Select system status/test.
  • Select fire protection.
  • Select SDCU.
   (2) If the display shows the Main Menu of the SDCU, select "WIRING REPORT".
   (3) If there is a defect in the wiring:
  • The display gives information about the location of the defect, for example: WIRING DEFECT BETWEEN SMOKE DET LAV A (1WQ) AND SMOKE DET LAV D (4WQ).
  • Refer to the affected troubleshooting procedure TSM 26-17-00-810-805.
   (4) If there is no wiring defect, the display shows "No FAILURE".
5. Close-up
Subtask 26-17-00-860-055-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
[Rev.10 from 2021] 2026.03.31 23:44:07 UTC