W DOC AIRBUS | AMM A320F

Reactivation of the Smoke-Detection Control Unit (SDCU)


TASK 26-17-00-440-802-A
Reactivation of the Smoke-Detection Control Unit (SDCU)


1. Reason for the Job
MMEL 26-17-02A
SMOKE DETECTION CONTROL UNIT (SDCU) (FAA ONLY)
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
LABEL - INOPERATIVE DO NOT ENTER
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
3. Job Set-up
Subtask 26-17-00-861-059-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
4. Procedure
Subtask 26-17-00-440-051-A ** ON A/C NOT FOR ALL
A. Reactivation
   (1) Do the trouble shooting of the SDCU with the Fault Symptoms as entry into the TSM.
   (2) Remove the placard LABEL - INOPERATIVE DO NOT ENTER from the related lavatory door.
   (3) Unlock the related lavatory door.
   (4) Remove the WARNING NOTICE(S).
5. Close-up
Subtask 26-17-00-862-060-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
[Rev.10 from 2021] 2026.03.31 23:44:03 UTC