Deactivation of the Smoke-Detection Control Unit (SDCU)
TASK 26-17-00-040-802-A
Deactivation of the Smoke-Detection Control Unit (SDCU)
MMEL 26-17-02A
SMOKE DETECTION CONTROL UNIT (SDCU) (FAA ONLY)
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 26-17-00-861-057-A ** ON A/C NOT FOR ALL
Subtask 26-17-00-040-051-A ** ON A/C NOT FOR ALL
Subtask 26-17-00-862-058-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 23:44:01 UTC
Deactivation of the Smoke-Detection Control Unit (SDCU)
Task Summary
1. Reason for the Job| Access | Test | Specific Tools | Mhr | E/T | Nb Men |
|---|---|---|---|---|---|
| NO | NO | NO | 0.3 | 0.3 | 1 |
MMEL 26-17-02A
SMOKE DETECTION CONTROL UNIT (SDCU) (FAA ONLY)
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | LABEL - INOPERATIVE DO NOT ENTER |
| No specific | 1 | WARNING NOTICE(S) |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
Subtask 26-17-00-861-057-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
4. Procedure(1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 26-17-00-040-051-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) Make sure that the lavatory waste receptacle is empty.
(2) Close and lock the related lavatory door.
(3) Put a placard LABEL - INOPERATIVE DO NOT ENTER on the related lavatory door.
(4) Put a WARNING NOTICE(S) in the cockpit to tell the crew that the smoke detector of the related lavatory does not operate.
(5) Make an entry in the logbook.
5. Close-up(1) Make sure that the lavatory waste receptacle is empty.
(2) Close and lock the related lavatory door.
(3) Put a placard LABEL - INOPERATIVE DO NOT ENTER on the related lavatory door.
(4) Put a WARNING NOTICE(S) in the cockpit to tell the crew that the smoke detector of the related lavatory does not operate.
(5) Make an entry in the logbook.
Subtask 26-17-00-862-058-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
(1) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
(1) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).