Deactivation of the Smoke-Detection Control Unit (SDCU)


TASK 26-17-00-040-802-A
Deactivation of the Smoke-Detection Control Unit (SDCU)


Task Summary
Access Test Specific Tools Mhr E/T Nb Men
NONONO0.30.31
1. Reason for the Job
MMEL 26-17-02A
SMOKE DETECTION CONTROL UNIT (SDCU) (FAA ONLY)
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
LABEL - INOPERATIVE DO NOT ENTER
No specific
1
WARNING NOTICE(S)
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
3. Job Set-up
Subtask 26-17-00-861-057-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
4. Procedure
Subtask 26-17-00-040-051-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) Make sure that the lavatory waste receptacle is empty.
   (2) Close and lock the related lavatory door.
   (3) Put a placard LABEL - INOPERATIVE DO NOT ENTER on the related lavatory door.
   (4) Put a WARNING NOTICE(S) in the cockpit to tell the crew that the smoke detector of the related lavatory does not operate.
   (5) Make an entry in the logbook.
5. Close-up
Subtask 26-17-00-862-058-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).