Functional Test of the Cargo-Compartment Smoke-Detector Sensitivity
TASK 26-16-00-720-001-A
Functional Test of the Cargo-Compartment Smoke-Detector Sensitivity
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 26-16-00-861-053-A ** ON A/C NOT FOR ALL
Subtask 26-16-00-720-050-A ** ON A/C NOT FOR ALL
Subtask 26-16-00-410-051-C ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 23:43:55 UTC
Functional Test of the Cargo-Compartment Smoke-Detector Sensitivity
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | 1 | MULTIMETER - STANDARD |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| REFERENCE | DESIGNATION |
|---|---|
| No specific | test plug |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 130 | FWD CARGO COMPT AFT BULKHEAD OF AVNCS COMPT TO FWD PRESSURE BULKHEAD OF WING CENTER BOX |
| 150 | AFT CARGO COMPARTMENT FWD PRESS BULKHEAD TO AFT BULKHEAD OF AFT CARGO COMPARTMENT |
| 160 | BULK CARGO COMPARTMENT AFT BULKHEAD OF AFT CARGO COMPARTMENT TO AFT BULKHEAD OF BULK CARGO COMPARTMENT |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 26-16-00-710-001-A | Operational Check of Cargo Compartment Smoke Detection by PTT |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 52-30-00-860-002-A | Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| ESPM 2044110 | |
| ESPM 2048210 | |
Subtask 26-16-00-861-053-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 26-16-00-010-050-C ** ON A/C NOT FOR ALL (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
B. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE below forward cargo-compartment door 825.
(2) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE below aft cargo-compartment door 826.
(3) Open forward cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-001).
(4) Open aft cargo-compartment door 826 (Ref. AMM TASK 52-30-00-860-001).
Subtask 26-16-00-865-051-A ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE below forward cargo-compartment door 825.
(2) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE below aft cargo-compartment door 826.
(3) Open forward cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-001).
(4) Open aft cargo-compartment door 826 (Ref. AMM TASK 52-30-00-860-001).
C. Open, safety and tag this(these) circuit breaker(s):
Subtask 26-16-00-020-051-B ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/SDCU/CHAN1 | 11WQ | C06 |
| 122VU | AIR COND/SDCU/CHAN2 | 12WQ | T18 |
D. Disconnect the Smoke Detector
(1) If necessary, remove the grid.
(2) Disconnect electrical connector 1WH-A from smoke detector 1WH.
Subtask 26-16-00-480-050-A ** ON A/C NOT FOR ALL (1) If necessary, remove the grid.
(2) Disconnect electrical connector 1WH-A from smoke detector 1WH.
E. Connect a test plug and a MULTIMETER - STANDARD between smoke detector 1WH and electrical connector 1WH-A ESPM 2044110 and ESPM 2048210.
Subtask 26-16-00-480-050-B ** ON A/C NOT FOR ALL NOTE: The minimum input resistance of the multimeter must be 10 MEG OHMS.
E. Connect a test plug and a MULTIMETER - STANDARD between the smoke detector 3WH and the electrical connector 3WH-A ESPM 2044110 and ESPM 2048210.
Subtask 26-16-00-865-064-A ** ON A/C NOT FOR ALL NOTE: The minimum input resistance of the multimeter must be 10 MEG OHMS.
F. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/SDCU/CHAN1 | 11WQ | C06 |
| 122VU | AIR COND/SDCU/CHAN2 | 12WQ | T18 |
Subtask 26-16-00-720-050-A ** ON A/C NOT FOR ALL
A. Test of the Cargo-Compartment Smoke-Detector Sensitivity (ionization type smoke detector)
Subtask 26-16-00-720-051-A ** ON A/C NOT FOR ALL NOTE: This paragraph is only applicable to ionization type smoke-detectors P/N PAI2800-01.
| ACTION | RESULT |
|---|---|
1.On the smoke detector TEST PLUG ASSEMBLY:
| On the voltmeter:
|
B. Test of the Cargo-Compartment Smoke-Detector Sensitivity (photo-electric type smoke detector)
Subtask 26-16-00-865-062-A ** ON A/C NOT FOR ALL NOTE: This paragraph is only applicable to photo-electric type smoke-detectors P/N PPA1100-XX, PPA1101-XX, PPA1102-XX and PPA1103-XX.
| ACTION | RESULT |
|---|---|
1.On the smoke detector TEST PLUG ASSEMBLY:
| On the multimeter:
|
C. Open, safety and tag this(these) circuit breaker(s):
Subtask 26-16-00-420-051-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/SDCU/CHAN1 | 11WQ | C06 |
| 122VU | AIR COND/SDCU/CHAN2 | 12WQ | T18 |
D. Connect the Smoke Detector
(1) Disconnect the electrical connectors of the TEST PLUG ASSEMBLY ESPM 2044110 and ESPM 2048210.
(2) Connect the electrical connector 1WH-A to the smoke detector 1WH.
Subtask 26-16-00-869-050-A ** ON A/C NOT FOR ALL (1) Disconnect the electrical connectors of the TEST PLUG ASSEMBLY ESPM 2044110 and ESPM 2048210.
(2) Connect the electrical connector 1WH-A to the smoke detector 1WH.
E. Do para's 3D to 4D for each remaining cargo-compartment smoke-detectors.
Subtask 26-16-00-869-050-B ** ON A/C NOT FOR ALL E. Do paragraphs 3D to 4C for each remaining cargo-compartment smoke-detectors.
Subtask 26-16-00-865-063-A ** ON A/C NOT FOR ALL F. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 26-16-00-710-067-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/SDCU/CHAN1 | 11WQ | C06 |
| 122VU | AIR COND/SDCU/CHAN2 | 12WQ | T18 |
G. Do the Operational Test of the Cargo-Compartment Smoke-Detection system by PTT (Ref. AMM TASK 26-16-00-710-001).
5. Close-upSubtask 26-16-00-410-051-C ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) If removed, install the grid.
(3) Close forward cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-002).
(4) Close aft cargo-compartment door 826 (Ref. AMM TASK 52-30-00-860-002).
(5) Remove the access platform(s).
Subtask 26-16-00-862-059-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) If removed, install the grid.
(3) Close forward cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-002).
(4) Close aft cargo-compartment door 826 (Ref. AMM TASK 52-30-00-860-002).
(5) Remove the access platform(s).
B. Put the aircraft back to its initial configuration.
(1) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
(1) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
Smoke-Detector Test-Plug Assembly