Installation of the APU Fire-Detection Unit (FDU)
TASK 26-13-34-400-001-A
Installation of the APU Fire-Detection Unit (FDU)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 26-13-34-860-050-A
Subtask 26-13-34-420-050-A
Subtask 26-13-34-860-052-A Subtask 26-13-34-410-050-A
[Rev.10 from 2021]
2026.03.31 23:43:41 UTC
Installation of the APU Fire-Detection Unit (FDU)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | CAP - BLANKING |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 127 | REAR AVIONIC COMPARTMENT |
| 824 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 26-13-00-710-001-A | Operational Test of the APU Fire and Overheat Detection System |
| TASK 31-32-00-860-005-A | Procedure to Get Access to the SYSTEM REPORT/TEST FIRE PROT Page |
| TASK 31-60-00-860-001-A | EIS Start Procedure |
| TASK 31-60-00-860-002-A | EIS Stop Procedure |
| TASK 52-41-00-410-002-A | Close the Avionics Compartment Doors after Access |
Subtask 26-13-34-860-050-A
A. In the cockpit, on the OVERHEAD CTL & IND panel 25VU, make sure that the WARNING NOTICE(S) is in position to tell persons not to start the APU.
Subtask 26-13-34-010-051-A B. Get Access
(1) Make sure that ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position.
(2) Make sure that the access door 824 is open.
Subtask 26-13-34-865-051-A (1) Make sure that ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position.
(2) Make sure that the access door 824 is open.
C. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | APU/FIRE AND OVHT/DET/LOOP B | 2WG | L44 |
| 121VU | APU/FIRE AND OVHT/DET/LOOP A | 1WG | L43 |
Subtask 26-13-34-420-050-A
A. Install the APU Fire Detection Unit (FDU)
(1) Put the fire detection unit (1) on its support (4).
(2) Install the washers (3), the screws (2) and tighten them.
(3) Remove the CAP - BLANKING from the electrical connectors (5) and (6).
(4) Connect the electrical connectors (5) and (6) to the fire detection unit (1).
Subtask 26-13-34-865-052-A (1) Put the fire detection unit (1) on its support (4).
(2) Install the washers (3), the screws (2) and tighten them.
(3) Remove the CAP - BLANKING from the electrical connectors (5) and (6).
(4) Connect the electrical connectors (5) and (6) to the fire detection unit (1).
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 26-13-34-860-051-A Subtask 26-13-34-710-050-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | APU/FIRE AND OVHT/DET/LOOP B | 2WG | L44 |
| 121VU | APU/FIRE AND OVHT/DET/LOOP A | 1WG | L43 |
D. On the upper ECAM DU, make sure that the FIRE APU DET FAULT message has gone out of view.
Subtask 26-13-34-710-051-A E. Operational Test of the Engine Fire and Overheat Detection with the CFDS
(1) On one Multipurpose Control and Display Unit (MCDU), get the SYSTEM REPORT/TEST/FIRE PROT page (Ref. AMM TASK 31-32-00-860-005).
(2) Do this test:
(3) Do the operational test of the APU fire and overheat detection system (Ref. AMM TASK 26-13-00-710-001).
5. Close-up(1) On one Multipurpose Control and Display Unit (MCDU), get the SYSTEM REPORT/TEST/FIRE PROT page (Ref. AMM TASK 31-32-00-860-005).
(2) Do this test:
| ACTION | RESULT |
|---|---|
| 1.On the MCDU: | On the MCDU: |
|
|
| On the FDU APU page:
NOTE: Ignore other indications. |
Subtask 26-13-34-860-052-A Subtask 26-13-34-410-050-A
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the WARNING NOTICE(S).
(3) Close the access door 824 (Ref. AMM TASK 52-41-00-410-002).
(4) Remove the access platform(s).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the WARNING NOTICE(S).
(3) Close the access door 824 (Ref. AMM TASK 52-41-00-410-002).
(4) Remove the access platform(s).
APU Fire-Detection Unit