W DOC AIRBUS | AMM A320F

Removal of the APU Fire-Detection Unit (FDU)


TASK 26-13-34-000-001-A
Removal of the APU Fire-Detection Unit (FDU)


ZONE: 127
FIN: 13WG
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
127
REAR AVIONIC COMPARTMENT
824
 C. Referenced Information
REFERENCE
DESIGNATION
3. Job Set-up
Subtask 26-13-34-865-050-A
A. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUAPU/FIRE AND OVHT/DET/LOOP B2WGL44
121VUAPU/FIRE AND OVHT/DET/LOOP A1WGL43
Subtask 26-13-34-941-050-A
B. Safety Precautions
   (1) In the cockpit, on the OVERHEAD CTL & IND panel 25VU, put a WARNING NOTICE(S) to tell the persons not to start the APU .
Subtask 26-13-34-010-050-A
C. Get Access
   (1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
   (2) Open the access door 824.
4. Procedure
Subtask 26-13-34-020-050-A
A. Remove the APU Fire Detection Unit (FDU):
   (1) Disconnect the electrical connectors (5) and (6) from the Fire Detection Unit (1)
   (2) Put CAP - BLANKING on the electrical connectors (5) and (6).
   (3) Remove the screws (2) and the washers (3).
   (4) Remove the fire detection unit (1)
[Rev.10 from 2021] 2026.03.31 23:43:40 UTC