W DOC AIRBUS | AMM A320F

Removal of the Sensing Elements


TASK 26-13-15-000-001-A
Removal of the Sensing Elements


FIN: 21WG
FIN: 22WG
1. Reason for the Job
Self Explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
315AL, 316AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 29-00-00-864-001-A
Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action
TASK 52-41-00-010-001-A
Open the APU Doors for Access
TASK 52-41-23-010-801-A
Opening of Access Door 314AR
3. Job Set-up
Subtask 26-13-15-861-050-A
A. Aircraft Maintenance Configuration
   (1) Put a warning notice on the panel 25VU to tell persons not to start the APU.
   (2) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
   (3) De-pressurize the hydraulic systems (Ref. AMM TASK 29-00-00-864-001).
Subtask 26-13-15-865-050-A
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUAPU/FIRE AND OVHT/DET/LOOP B2WGL44
121VUAPU/FIRE AND OVHT/DET/LOOP A1WGL43
121VUAPU/APU/CTL2KDL42
121VUAPU/ECB/SPLY1KDL41
121VUAPU/FIRE/EXTIG/SQUIB/B2WFL39
121VUAPU/FIRE/EXTIG/SQUIB/A1WFL38
121VUAPU/FIRE/LP VALVE/NORM4WFM42
121VUAPU/FIRE/LP VALVE/STBY3WFM41
Subtask 26-13-15-010-050-A
C. Get Access
   (1) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position below the APU compartment.
   (2) Open access door 314AR and safety it in the open position.
(Ref. AMM TASK 52-41-23-010-801).
   (3) Open the APU access doors 315AL and 316AR (Ref. AMM TASK 52-41-00-010-001)
   (4) Set the LIGHT control switch 11LJ to the ON position.
4. Procedure
Subtask 26-13-15-020-050-A
A. Removal of the APU Fire Sensors
NOTE: The procedure is the same for the APU fire sensors 21WG and 22WG.
   (1) Turn the screws (2) and open the dual clamps (3).
   (2) Keep the support bushes (1).
   (3) Disconnect the electrical connector 21WG(22WG)-A (9).
   (4) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (5) Remove the screws (6) and the washers (5).
   (6) Disconnect the fire/overheat detector 21WG(22WG) (7) with the sensing element.
   (7) Remove and discard the O-rings (4).
   (8) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
[Rev.10 from 2021] 2026.04.05 10:34:55 UTC