W DOC AIRBUS | AMM A320F

Installation of the Pylon Fire Detector


TASK 26-12-16-400-805-A
Installation of the Pylon Fire Detector


WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
WARNING: YOU MUST NOT TOUCH HOT PARTS WITHOUT APPLICABLE GLOVES. HOT PARTS CAN CAUSE AN INJURY.
ZONE: 415
ZONE: 425
FIN: 3WD1
FIN: 3WD2
FIN: 4WD1
FIN: 4WD2
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
98D26203003001
1
CAMBERING TOOL
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
415
LOWER PYLON
425
LOWER PYLON
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 26-12-16-000-804-A
Removal of the Pylon Fire-Detector Ramp-Assembly
TASK 26-12-16-400-804-A
Installation of the Pylon Fire-Detector Ramp-Assembly
3. Job Set-up
Subtask 26-12-16-010-075-A
A. Removal of the Pylon Fire-Detector Ramp-Assembly
   (1) Make sure that the pylon fire-detector ramp-assembly is removed (Ref. AMM TASK 26-12-16-000-804).
4. Procedure
Subtask 26-12-16-420-066-A
A. Installation of the Fire Detector
CAUTION: DO NOT USE ELECTRICAL OR PNEUMATIC TOOLS TO LOOSEN OR TIGHTEN THE QUARTER-TURN FASTENER ON THE FIRE DETECTOR CLAMP. ONLY USE A MANUAL SCREWDRIVER. ELECTRICAL OR PNEUMATIC TOOLS WILL CAUSE THE FASTENER TO TURN TOO MUCH AND POSSIBLY TO BREAK.
CAUTION: DO NOT BEND THE MANIFOLD OF THE SENSING ELEMENT. IF YOU BEND IT, YOU CAN CAUSE DAMAGE TO THE WELDING.
   (1) Carefully install the two responder units (3) on the rail assembly (4).
   (2) Install the four washers (2) and screws (1) for each responder unit (3) and tighten them.
   (3) Use the 98D26203003001 CAMBERING TOOL to make sure that the pylon fire-detector loop is bent correctly. The bend radius must be 9.5 mm (0.37 in.). This prevents the risk of rupture between the loop and the fire detector.
   (4) Carefully install the sensing element (7) in the clamps (6), (9) and (10). Do these steps along the sensing element (7) to install it:
     (a) Make sure that the sensing element (7) is at a minimum distance of 5 mm (0.20 in.) from the ramp assembly (4).
     (b) Make sure that the end of the sensing element (7) is at a maximum distance of 25.4 mm (1.00 in.) from the clamp (10).
     (c) Make sure that the sensing element (7) is correctly installed in the center of the groove of the clamps (6), (9) and (10).
     (d) Close the clamps (6) and turn the related quarter-turn fasteners (5) by one quarter of a turn.
     (e) Close the clamps (9) and turn the related quarter-turn fasteners (8) by one quarter of a turn.
     (f) Close the clamps (10) and turn the related quarter-turn fasteners (11) by one quarter of a turn.
5. Close-up
Subtask 26-12-16-420-067-A
A. Installation of the Pylon Fire-Detector Ramp-Assembly
   (1) Install the pylon fire-detector ramp-assembly (Ref. AMM TASK 26-12-16-400-804).
[Rev.10 from 2021] 2026.03.31 23:42:57 UTC