Installation of the Pylon Fire Detector
TASK 26-12-16-400-803-A
Installation of the Pylon Fire Detector
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 26-12-16-010-069-A ** ON A/C NOT FOR ALL
Subtask 26-12-16-420-058-A ** ON A/C NOT FOR ALL
Subtask 26-12-16-420-059-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 23:42:52 UTC
Installation of the Pylon Fire Detector
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AFTER SHUTDOWN. THE ENGINE CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS INSTRUCTION, INJURY CAN OCCUR.
WARNING:
ALWAYS USE APPLICABLE GLOVES TO TOUCH HOT PARTS. HOT PARTS CAN CAUSE INJURY TO PERSONS.
ZONE: 415
ZONE: 425
FIN: 3WD1 ** ON A/C NOT FOR ALL
FIN: 3WD2 ** ON A/C NOT FOR ALL
FIN: 4WD1 ** ON A/C NOT FOR ALL
FIN: 4WD2 ** ON A/C NOT FOR ALL
1. Reason for the JobZONE: 425
FIN: 3WD1 ** ON A/C NOT FOR ALL
FIN: 3WD2 ** ON A/C NOT FOR ALL
FIN: 4WD1 ** ON A/C NOT FOR ALL
FIN: 4WD2 ** ON A/C NOT FOR ALL
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| 98D26203003001 | 1 | CAMBERING TOOL |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 415 | LOWER PYLON |
| 425 | LOWER PYLON |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 26-12-16-000-802-A | Removal of the Pylon Fire-Detector Ramp-Assembly |
| TASK 26-12-16-400-802-A | Installation of the Pylon Fire-Detector Ramp-Assembly |
Subtask 26-12-16-010-069-A ** ON A/C NOT FOR ALL
A. Removal of the Pylon Fire-Detector Ramp-Assembly
(1) Make sure that the pylon fire-detector ramp-assembly is removed (Ref. AMM TASK 26-12-16-000-802).
4. Procedure(1) Make sure that the pylon fire-detector ramp-assembly is removed (Ref. AMM TASK 26-12-16-000-802).
Subtask 26-12-16-420-058-A ** ON A/C NOT FOR ALL
A. Installation of the Fire Detector
(2) Install the washers (2) and the screws (1) and tighten them.
(3) Use the 98D26203003001 CAMBERING TOOL to make sure that the pylon fire-detector loop is bent correctly. The bend radius must be 9.5 mm (0.37 in.). This prevents the risk of rupture between the loop and the fire detector.
(4) Carefully install the sensing element (6) in the clamps (5) and (8). Do these steps along the sensing element (6) to install it:
(a) Make sure that the sensing element (6) is correctly installed in the center of the groove of the clamps (5) and (8).
(b) Close the clamps (8) and lock them with the quarter-turn fasteners (7).
(c) Close the clamps (5) and lock them with the quarter-turn fasteners (4).
Subtask 26-12-16-420-058-B ** ON A/C NOT FOR ALL CAUTION:
DO NOT USE ELECTRICAL OR PNEUMATIC TOOLS TO LOOSEN OR TIGHTEN THE QUARTER-TURN FASTENER ON THE FIRE DETECTOR CLAMP. ONLY USE A MANUAL SCREWDRIVER. ELECTRICAL OR PNEUMATIC TOOLS WILL CAUSE THE FASTENER TO TURN TOO MUCH AND POSSIBLY TO BREAK.
CAUTION:
DO NOT BEND THE MANIFOLD OF THE SENSING ELEMENT. IF YOU BEND IT, YOU CAN CAUSE DAMAGE TO THE WELDING.
(1) Install the responder unit (3) on the rail assembly (9). (2) Install the washers (2) and the screws (1) and tighten them.
(3) Use the 98D26203003001 CAMBERING TOOL to make sure that the pylon fire-detector loop is bent correctly. The bend radius must be 9.5 mm (0.37 in.). This prevents the risk of rupture between the loop and the fire detector.
(4) Carefully install the sensing element (6) in the clamps (5) and (8). Do these steps along the sensing element (6) to install it:
(a) Make sure that the sensing element (6) is correctly installed in the center of the groove of the clamps (5) and (8).
(b) Close the clamps (8) and lock them with the quarter-turn fasteners (7).
(c) Close the clamps (5) and lock them with the quarter-turn fasteners (4).
A. Installation of the Fire Detector
(2) Install the washers (3) and the screws (2) and tighten them.
(3) Use the 98D26203003001 CAMBERING TOOL to make sure that the pylon fire-detector loop is bent correctly. The bend radius must be 9.5 mm (0.37 in.). This prevents the risk of rupture between the loop and the fire detector.
(4) Carefully install the sensing element (7) in the clamps (6) and (9). Do these steps along with the sensing element (7) to install it:
(a) Make sure that the sensing element (7) is correctly installed in the center of the groove of the clamps (6) and (9).
(b) Close the clamps (9) and lock them with the quarter-turn fasteners (8).
(c) Close the clamps (6) and lock them with the quarter-turn fasteners (5).
5. Close-upCAUTION:
DO NOT USE ELECTRICAL OR PNEUMATIC TOOLS TO LOOSEN OR TIGHTEN THE QUARTER-TURN FASTENER ON THE FIRE DETECTOR CLAMP. ONLY USE A MANUAL SCREWDRIVER. ELECTRICAL OR PNEUMATIC TOOLS WILL CAUSE THE FASTENER TO TURN TOO MUCH AND POSSIBLY TO BREAK.
CAUTION:
DO NOT BEND THE MANIFOLD OF THE SENSING ELEMENT. IF YOU BEND IT, YOU CAN CAUSE DAMAGE TO THE WELDING.
(1) Install the responder units (4) on the rail assembly (1). (2) Install the washers (3) and the screws (2) and tighten them.
(3) Use the 98D26203003001 CAMBERING TOOL to make sure that the pylon fire-detector loop is bent correctly. The bend radius must be 9.5 mm (0.37 in.). This prevents the risk of rupture between the loop and the fire detector.
(4) Carefully install the sensing element (7) in the clamps (6) and (9). Do these steps along with the sensing element (7) to install it:
(a) Make sure that the sensing element (7) is correctly installed in the center of the groove of the clamps (6) and (9).
(b) Close the clamps (9) and lock them with the quarter-turn fasteners (8).
(c) Close the clamps (6) and lock them with the quarter-turn fasteners (5).
Subtask 26-12-16-420-059-A ** ON A/C NOT FOR ALL
A. Installation of the Pylon Fire-Detector Ramp-Assembly
(1) Install the pylon fire-detector ramp-assembly (Ref. AMM TASK 26-12-16-400-802).
(1) Install the pylon fire-detector ramp-assembly (Ref. AMM TASK 26-12-16-400-802).
Pylon Fire Detector